1、 Product Introduction:

1. Temperature range: ambient temperature plus 7 ℃ to 100 ℃

2. Utilizing APT.line ™ Technology achieves high temperature accuracy

3. Circulating air

4. Controller with LCD display

5. Exhaust valve electromechanical control

6. Interior door made of safety glass (ESG)

7. 2 chrome plated sockets

8. Stackable

9. Integrated independently adjustable temperature safety device Class 3.1 (DIN 12880), equipped with optical alarm

10. Ergonomic handle design

11. USB interface for recording data

2、 Technical parameters:

Product Model BF056-230V1 BF056UL-120V1
Choose a model standard standard
Item code 9010-0313 9010-0314
measurement
Internal volume [L] 59 59
Net weight of equipment (unloaded) [kg] 38 38
Maximum total load [kg] 70 70
Maximum load per partition [kg] 30 30
The dimensions of the casing do not include additional components and connectors
Net weight width [mm] 560 560
Net weight at height [mm] 625 625
Depth net weight [mm] 565 565
Wall distance from rear [mm] 160 160
Wall to side distance [mm] 100 100
internal dimensions
Width [mm] 400 400
Height [mm] 440 440
Depth [mm] 340 340
number of doors
outer gate 1 1
Data related to the environment
Energy consumption at 37 ℃ [Wh/h] 55 55
Sound pressure level [dB (A)] 43 43
firmware
Number of partitions (hours/maximum) 2/4 2/4
Temperature performance data
The temperature range exceeds the indoor temperature by 7 ℃ to [℃] 100 100
The temperature deviation is 37 ℃ [± K] 0.2 0.2
Temperature fluctuation at 37 ℃ [± K] 0.1 0.1
Heating time to 37 ℃ [min] 6 6
The recovery time after opening the door in 30 seconds is 37 ℃ [min] 3 3
Electrical data
Rated voltage [V] 230 120
Power frequency [Hz] 50/60 60
Rated power [kW] 0.4 0.4
Equipment safety device [A] 6.3 12.5
Phase (rated voltage) 1~ 1~

1. All technical data is only applicable to standard specifications of unloaded equipment at an ambient temperature of 22 ± 3 ℃ and a power supply voltage fluctuation of ± 10%. Determine temperature data according to BINDER factory standards and DIN 12880:2007, and adapt to the recommended wall gap of 10% of the internal chamber height, width, and depth. For series devices, all data are typical averages. We reserve the right to make technical changes.