Product Application
■ Annealing and heat treatment process
Industrial furnace equipment
Smelting and rolling steel
■ Cogeneration unit
Power engineering and reactors
Industries such as pharmaceuticals, food, electricity, metallurgy, glass, chemicals, rubber, and textiles
Technical data
| Thermocouple core | Platinum rhodium 30- Platinum rhodium 6 (B): 600-1700 ℃ |
| 铂铑13-铂 (R):0~1600℃ | |
| Platinum rhodium 10 platinum (S): 0-1600 ℃ | |
| Nickel chromium nickel silicon (K): -200~1150 ℃ | |
| Nickel chromium copper nickel (E): -200~800 ℃ | |
| Iron copper nickel (J): -200~750 ℃ | |
| Copper Copper Nickel (T): -200~350 ℃ | |
| accuracy class | Level II |
| Extension tube | Stainless steel or the same material as the protective tube, with a length of 130mm |
| Minimum depth of placement | ≥100mm, Excluding special products |
| process connection | Stainless steel, thread/chuck/flange |
| Protection tube | Steel protective tube<1100 ℃, diameter 16mm, 20mm |
| Corundum protective tube<1600 ℃, diameter 16mm, 20mm | |
| response time | t0.5,5s~90s |
| Junction box | Cast aluminum casing, outlet thread M20 * 1.5, IP65 |
| Transmitter | Analog output 4-20mA (see data sheet 7401) |
Instructions
·We will select the appropriate protective tube material based on the temperature range and requirements you have chosen. Please do not use it beyond the selected temperature range;
·In order to better select FUSide products, please provide the highest operating temperature (including peak temperature) during selection;
·For specific material parameters of metal and non-metal protective tubes, please refer to Table 7600-2 on page 91 and Table 7600-3 on page 92;
·When choosing a module with a temperature transmitter, please indicate the temperature range of the transmitter, and we will help you set it up together when it leaves the factory.