atomic absorption spectrophotometerIntroduction to AA6810 Spectrometer
Atomic absorption spectrophotometer AA6810 spectrometerDeveloped and produced by product engineers and application engineers with decades of experience in atomic absorption, with personnel sourced from the original companyagilentAtomic absorption team. The main products of the company at present are:AA6810 spectrometerThe 6810 model includes 6810F flame, 6810 flame rapid multi-element analyzer, 6810 graphite furnace, etc. Currently, the 6810 model is optimized and upgraded based on the performance of the original Agilent 4510.
1AA6810 spectrometer
The same instrument has both flame atomization and graphite furnace atomization functions, and can be paired with a hydride generator function.
project |
|
hollow cathode lamp |
6 lamp positions |
slit |
Six level slit |
Resolution (manganese double line) |
<20% |
Flame function |
have |
Graphite furnace function |
have |
autosampler |
85 bit automatic sampler |
flame+Graphite furnace controller+automatic sampler
The multimedia graphite furnace visualization system in China can intuitively monitor the dynamic evolution of the sample solution during the drying, ashing, and burning processes inside the graphite tube. It is convenient to observe the optimal position and depth of the automatic sampler capillary injection needle entering the graphite tube, as well as the position of the platform inserted into the graphite tube, ensuring analysis accuracy and the lifespan of the graphite tube. It is also a training tool for *.
IIAA6810TECHNICAL INDEX
host
Wavelength range 190-900nm
When conducting multi-element analysis on a 6-light lighthouse, there is no need to replace the lights
Wavelength repeatability ± 0.1nm
Wavelength accuracy: ± 0.2nm across the entire wavelength range
Absorption range 0-2.5 ABS
When the resolution spectral bandwidth is 0.2nm, it can separate manganese double lines (279.5 and 279.8)
And the valley peak energy ratio is less than 20%
Spectral bandwidth (6 levels, 4 levels optional) 0.1nm, 0.2nm, 0.4nm, 0.7, 1.0, 2.0nm
Static baseline drift ≤ 0.002ABS/30min (Cu)
Weight 80kg
Size 500 * 450 * 430 (mm)
Number of gratings 1800/mm
D2 background subtraction method: When the background signal is 1ABS, the ability to deduct background is ≥ 50 times
Self absorption background deduction method
Power supply 220V AC
Flame system
Air acetylene flame combustion head 100mm
Ignition dynamic baseline drift ≤ 0.004ABS/30min (Cu)
Sensitivity (Cu) characteristic concentration ≤ 0.025ug/ml/1%
Precision relative standard deviation ≤ 0.5% (Cu, absorbance>0.8ABS)
(Detection limit Cu ≤ 0.004ug/ml)
Automatic cut-off of gas in case of insufficient pressure, power interruption, abnormal shutdown, or mismatched combustion head in the safety system
Graphite furnace system
The working temperature of graphite furnace is from room temperature to 3000 ℃
The maximum heating rate is ≥ 2000 ℃/s
Characteristic quantities Cd ≤ 1pg, Cu ≤ 10pg
Precision relative standard deviation Cd ≤ 3%, Cu ≤ 3%
Weight 60kg
Size 550 * 450 * 280 (mm)
Safety overcurrent protection
Insufficient protection gas pressure alarm/automatic stop of temperature rise
Insufficient cooling water flow alarm/automatic stop of temperature rise
Power supply 220V AC
Power 7000w
IIIAA6810 spectrometer
All functions are controlled and operated by a PC, and flame and graphite furnaces can be flexibly selected. Unique optical mechanical design, safe and convenient flame system, advanced graphite furnace temperature control technology, optional background technology deduction, and various convenient functions provided by the workstation, adapt to your pursuit of precise measurement results in automation.
- Adopting excellent design from Agilent Technologies in the United States, the instrument has strong stability and long service life;
- The software is converted to a fully Chinese operating interface, making the operation more concise and convenient;
- The smallest instrument of its kind has a volume of 700 × 550 × 440 and occupies the smallest laboratory space;
- Switching between flame and graphite furnace within 10 seconds;
- Excellent high-precision automatic sampling technology for graphite furnaces;
- A flexible online dilution system can greatly reduce analysis operations and improve analysis efficiency;
- Stable and reliable graphite furnace atomization system, using PID technology to achieve more precise temperature control;
- Advanced and reliable security protection system ensures the safety of operators.
- Using highly sensitive flame sensors to eliminate interference from external light
- Realize safer control over abnormal situations, such as insufficient pressure, air leakage, engine shutdown, etc
- Added working software for the hydride generator method
- The software has added a method storage function, allowing users to retrieve standard curves at any time after storage, which can save analysis time
- Graphite furnace atomic absorption adds 85 automatic samplers
4AA6810 spectrometerStandard configuration
Serial Number |
product name |
model |
quantity |
unit |
1 |
6810 |
Standard type |
1 |
tower |
2 |
Graphite furnace controller |
|
1 |
tower |
4 |
air compressor |
no oil |
1 |
tower |
6 |
hollow cathode lamp |
Copper, manganese |
2 |
only |
7 |
software |
AA6810 Workstation Software |
1 |
fix |
8 |
atomizer |
|
1 |
only |
9 |
100mm combustion head |
|
1 |
individual |
10 |
Acetylene pressure reducing valve |
|
1 |
individual |
11 |
Oxygen pressure reducing valve |
|
1 |
individual |
12 |
Acetylene pipeline |
|
10 |
rice |
14 |
GRAPHITE TUBE |
|
2 |
root |
15 |
Micro sampler |
|
1 |
individual |
16 |
tool |
Screwdrivers, wrenches, etc |
5 |
grasp |
17 |
sealing washer |
|
8 |
individual |
18 |
Regarding the light plate |
|
1 |
individual |
19 |
data line |
|
1 |
root |
20 |
power line |
|
1 |
root |
21 |
fuse |
|
7 |
root |
22 |
Waste liquid pipe |
|
1 |
root |
24 |
instructions |
|
2 |
share |
25 |
outlet |
|
1 |
individual |
26 |
computer |
Hewlett-Packard |
1 |
tower |