Ventis ™ MX4 Multi Gas Detector Product Overview
Properly configured Ventis ™ MX4 can effectively ensure your safety and elevate your gas detection plan to a whole new level.
*Can detect one to four gases through multiple sensor options
*Sampling can be done from up to 100 feet away using an optional integrated sampling pump
*Safe orange casing can effectively improve instrument visibility
*Realize multi gas detection with a single gas detector size, highlighting portability
*The use of reinforced batteries can support up to 20 hours of normal operation (without pump)
*Finding a better way to detect gases through iNet compatible Ventis
Detectable gases:Methane, carbon monoxide, hydrogen sulfide, combustible gases, nitrogen dioxide, oxygen, sulfur dioxide
Ventis ™ MX4 Multi Gas DetectorFeatures and Functions
The top of the monitor's casing (front of the monitor) is divided into two main parts. As shown below, the upper part contains the sensor opening. The lower part has user interface features, an LCD display screen and two buttons. List the general functions of each feature below. As shown in the figure, there are differences in the air sampling method and visual alarm indication between diffusion type and pump suction type monitoring instruments.
|
serial number |
feature |
function |
|
1 |
Visual alarm indication |
Indicate alarms or warnings; The frequency varies according to the alarm level. Also used for confidence indication. |
|
2 |
Pump inlet (pump suction) Sensor opening (diffusion type) |
Air inlet; Calibration and ventilation test gas inlet. |
|
3 |
LCDdisplay screen |
User interface: When the monitor is in the system, upper limit alarm, or lower limit alarm state, the backlight flashes |
|
4 |
Sound alarm port |
Only when the monitor is in the system, upper limit alarm, or lower limit alarm state; The frequency and tone vary with the alarm level. |
|
5 |
On/Off/Modebutton |
Used for startup and shutdown. Also used to skip a process in gas monitoring and configuration mode/Step one or move on to the next screen. Set values in configuration mode. |
|
6 |
Enterbutton |
Used to initiate a step in a process. Edit values in configuration mode. |
|
7 |
IrDAinterface |
Indicate that infrared data exchange is in progress. |
|
8 |
charging contacts |
Battery charging. |
Ventis ™ MX4 Multi Gas Detector Product Features and Advantages
function
advantage
Fill composite material structure
The sturdy construction provides excellent durability required for operation in harsh industrial environments
Compact and lightweight design
Multiple gas detection can be achieved with a single gas detector size, which is more portable and can be used as a personal monitor in configurations with or without a pump
IP66/67certification
Ensure that the monitor can be used in extreme and humid applications
One to four gas configurations
Allow you to choose and expand sensor configurations to meet monitoring needs at any time
Wide sensor detection range
The detection range of carbon monoxide is up to1000 ppmThe detection range of hydrogen sulfide is up to500 ppmThe detection range of nitrogen dioxide is up to150 ppmThe detection range of sulfur dioxide is up to150 ppmYou can check the corresponding changes when the dangerous situation exceeds the normal detection range
Interchangeable lithium and alkaline battery packs
Rechargeable lithium battery packs can work continuously for up to 12 Hours, while alkaline batteries can be used as emergency backup power or as the main power source in applications with low instrument usage frequency
Enhanced lithium battery pack
When using instruments without pumps, the rechargeable reinforced lithium battery pack can work continuously for up to 20 hours
Integrated sampling operation
Can achieve continuous monitoring or be used in conjunction with an integrated sampling pump for sampling operations (such as entering a confined space)
Language selectable instruments
Can use icon based displays to display English, French, and German, making it easy for a diverse workforce to use
Peak reading storage
Quick access to screen review for high leakage situations after alarm events, without the need to download data recording information
Continuous onboard data recording
Sensor data should be stored for at least three months, and regular reviews of gas leaks can be conducted to identify safety issues and areas for improvement
Sound, visual, and vibration alarms
95 dBSound volume, super brightness, and strong vibration alarms can provide multiple clear alarms under high noise and low brightness conditions
Programmable alarm function testing mode
Regularly notify users of issues with alarm function testing instruments and provide alerts to prevent their use when alarm function testing is not running at the required intervals
Calibration overdue alarm
Notify users and prevent normal use when the instrument is not calibrated within the specified time
STELandTWAReadings and alarms
Short term and time weighted average leakage measurement and alarm allow users to set potential instantaneous alarms at higher levels, enabling safe operation under prolonged exposure conditions with lower gas concentrations while providing alarm functionality
Quick-CalCalibration mode
Allow all sensors to be calibrated simultaneously using a mixed calibration gas, saving time and money
compatibleDS2 Docking Station™
Provide automatic calibration, alarm function testing, instrument diagnosis, and record maintenance functions to simplify instrument management and enable you to focus on other tasks; You only need to complete the docking to rest assured
applicableiNet
We provide gas monitoring services through a global instrument management system. by virtue ofiNetYour gas detection team will no longer need to purchase equipment to achieve factory monitoring and deliver services.
Can provide safe orange color
Bright orange film can improve visibility in dark enclosed spaces
Product Specifications
Ventis ™ Technical parameters of MX4 multi gas detector
|
Technical Specifications |
|
|
size |
103 mm x 58 mm x 30 mm (4.1” x 2.3” x1.2”) - Ventis Lithium rechargeable battery model (standard configuration)172 mm x 67 mm x 66 mm (6.8”x 2.6”x 2.6”- Ventis |
|
(with pump), lithium rechargeable battery model (standard configuration) |
weight182 g (6.4 oz) - Ventis |
|
(with pump), lithium rechargeable battery model (standard configuration) |
Working temperature range-20Normally:°C- 50°C (-4°F-122° |
|
F) |
Working humidity rangeNormally:15% -90% |
|
Non condensing (continuous)display/ |
readingBacklit LCD display |
|
(LCD)power supply/ |
runtime |
|
(with pump) |
call the policeSuper bright indicator light, super strong sound alarm (in30 cmwithin the scope of95 dB |
|
)And vibration alarm |
sensorflammable gas/ methane – |
|
electrochemistry |
Testing ScopeCombustible gases:0-100% LELResolution |
|
0.1 ppm |
certification |
Ex d ia IIC T4
Ordering Guide
|
Ventis ™ MX4 Multi Gas Detector Ordering Guide |
quantity |
item |
|
1 annotation |
According to the orderVentis |
MX4 Portable multi gas monitoring instrumentThe type of monitor is indicated on the box label. Options:· entis MX4Diffusion type· Ventis MX4pump-suction type· |
|
1 |
Ventis MX4Pump suction (with conversion device) |
VentisMX4 |
|
Reference Guide 1 Ventis MX4 |
Product manual matching manual. |
install According to the order battery case According to the instructions on the box label, install one of the three battery types at the factory One of them. Options: · Charging Lithium ion · |
|
1 Rechargeable enhanced lithium-ion |
· |
alkalineAccording to the orderchargerUniversal power cord. Communication charger products include interchangeable plugs(USTheUKTheEU |
|
0 and 1 |
ABOUT |
).orCalibration cup 1 Diffusion type –includea 0 pump-suction type |
|
1 |
– |
includeaCalibration and ventilation test tube |
|
0 Diffusion type 1 |
– |
Two foot transparent tubeorOn site sampling tube 0 Diffusion type –includea |
|
1 |
pump-suction type |
– 10*Foot black pipe Final inspection and testing report Including the following factory settings Information: ·Date of instrument setting · Monitor part number(P/N) · Monitor serial number* (S/N)· For each sensor· P/N · S/N · type · position · Alarm level value · *Range gas value |
|
1 |
· |
Range reservation value |
Some factory set sensors or values may be subject to user changes.
Warranty Card--
Frequently Asked Questions1. Question:
2.Can I replace the sensor in Ventis MX4?Answer:
All sensors in Ventis MX4 are intelligent sensor modules that can be replaced on-site, making it convenient for users to replace them at will.Question:
3.Can I install any sensor combination in Ventis MX4?Answer:
The Ventis MX4 can be paired with combustible gas sensors, O2 sensors, and any two of the following toxic gas sensors: CO, H2S, SO2, and NO2Question:
Is there a replaceable battery pack available for Ventis MX4?
Answer:
The alkaline battery pack is suitable for Ventis MX4, and using three AAA alkaline batteries in diffusion mode will allow for an additional 8 hours of operation. And the alkaline battery pack can run for 4 hours in the pump suction Ventis MX4.
Manufacturer Introduction
