Product Details
Product Introduction
AWA6290LA multi-channel signal analyzer is a signal analysis instrument developed using computer multimedia technology. Strict synchronization between multiple channels, high-precision sampling, can be used for the acquisition, spectrum analysis, and related applications of analog signals such as noise and vibration. The analyzer consists of two parts: a signal generator and a signal collector. The generator has two independent channels, while the collector has an independent channel. Using Ethernet for data communication, convenient to use.
product image

All product images are provided by the manufacturer; Please refer to the actual item received!
Specifications
Main technical indicators of the collection section | |
Input channel |
2-20a |
Input signal type |
Voltage or ICP |
ADdigit |
24bit |
dynamic range |
Greater than 110dB |
frequency range |
1Hz~80kHz<0.1dB (1kHz as reference, 192k sampling) |
measurement range |
Voltage 5 μ V-10V (rms) Noise 25dB (A) to 140dB (A) (equipped with a microphone with 50mV sensitivity) Vibration range of 0.03m/s2 to 10000m/s2 (equipped with 1mV/(m/s2) accelerometer) When the sensitivity of the sensor changes, the measurement range will vary accordingly |
sampling frequency |
8192、 12kHz, 16384, 24kHz, 32768, 48kHz, 65536, 96kHz, 131072, 192kHz optional (192k sampling supports 8-channel synchronous sampling) |
Main indicators of the vocal section | |
output channel |
2a |
sampling frequency |
96kHz(Single channel output supports 192k sampling) |
frequency range |
0.5Hz~70kHz |
Maximum output amplitude |
9V(rms) |
Harmonic distortion |
<0.1% @8V |
Software Name |
Main functions |
FFTanalysis software |
FFTNumber of lines: 512, 1024, 2048, 4096, 8192, 16384, 32768, 65536 are optional. Analysis results: effective value, power spectral density, power spectrum, etc |
OCTAnd 1/3 OCT analysis |
Compliant with standards: IEC61260 CLASS 1, GB/T3241 Level 1 Frequency weighting: A, C, Z are optional The analysis results can be saved. Can record changes over time, with a minimum recording interval of 0.01s |
1/n OCTanalyze |
Compliant with standards: IEC61260 CLASS 1, GB/T3241 Level 1 Optional analysis frequency bands: 1/6, 1/12, 1/24, 1/48 |
Analysis of Total Noise Value |
Frequency weighting: Parallel A, B, C, D Time weighting: F, S, I, and peak Statistical analysis: It can perform statistical analysis on the average sound pressure level of a specified frequency weighting index The analysis results can be saved and recorded over time, with a minimum recording interval of 0.01s |
Vibration total value analysis |
Integrator: parallel (simultaneous) measurement of acceleration, velocity, and displacement Time constants: 1S, 8S Detection characteristics: effective value, peak value, peak to peak value |
Human body vibration analysis |
Measurement indicators: Wh weighting or parallel Wb, Wc, Wd, We, Wj, Wk, Wm weighting according to ISO8041. Time averaging methods: parallel (simultaneous) exponential, linear Time average constant: 1s (F range), 8s (S range) |
Speed analysis |
Using a measurement channel, connect it to a photoelectric tachometer or directly analyze the speed data through noise and vibration data. The speed data can be saved together with other measurement results |
Damping measurement |
Measure the natural frequency and damping coefficient of materials |
Collection and analysis |
Real time waveform acquisition and display, support multi-channel synchronous acquisition, can set limit triggering, and the acquisition time can be set. Can cut waveform data Paste Copy Save as, zoom in, zoom out Equipped with corresponding software for post analysis of recorded waveforms |
signal generator |
Can control the generation of sine signals, white noise, pink noise, sweep frequency, sweep amplitude and other types of signals |
Sound intensity analysis |
50Hz1/3 OCT sound intensity analysis up to 6.3kHz. (1/3 OCT analysis software package is required first) |
Measurement of sound power using sound intensity method |
Discrete point method for sound power measurement using sound intensity probe Compliant with standard: GBT 16404-1996 Acoustics - Determination of sound power level of noise sources by sound intensity method - Part 1: Measurement at discrete points |
Surface sound pressure method for measuring sound power |
1/3 OCTSimultaneously measure the frequency band sound power level and the A, C, Z weighted sound power levels. The number of measurement points is determined by the user's channel count, with a maximum of 12 channels (1/3 of the corresponding channel count needs to be purchased first for OCT analysis software authorization). |
Time history analysis software |
Real time display of spectrum analysis data for each channel; Zoom in Shrink and save the time history curve separately. Select the energy average, arithmetic average, maximum and minimum values, and data printing within the selected range |
waterfall diagram analysis |
Take data from 1/3 OCT analysis window, FFT analysis window, etc., and display the time, frequency, and amplitude values in three-dimensional mode to save graphics and analysis results. |
Building sound insulation measurement |
Measurement of airborne sound insulation, floor impact sound, and reverberation time |
Measurement of power transformers |
Compliant with GB/T 1094.10-2003 Power Transformers Part 10: Sound Level Determination |
Speaker measurement |
Can simultaneously measure speaker frequency response, second harmonic, third harmonic, etc; Measurable impedance curve of loudspeaker Can save frequency response and harmonic curves for comparison |
Drainage pipeline measurement |
Compliant with standard CJ/T 312-2009 Noise Testing Method for Building Drainage Pipeline System Equipped with reverberation measurement function (1/3 OCT analysis software must be provided first) |
Washing machine measurement |
GB/T 4214.1-2000Acoustics - Noise testing of household appliances and similar appliances - Part 1: General requirements GB/T 4214.4-2008Acoustic household appliances and similar appliances - Noise testing methods - Special requirements for washing machines and centrifuges - Dehydrators (1/3OCT analysis software must be provided first) |
customized for customers |
We can customize software that meets special measurement standards according to customer requirements |
After-sales service guarantee
l If there is a quality issue with the product and objections are raised within 7 days of sale and the product is not damaged, the China US Instrument Mall is responsible for unconditional free returns and exchanges;
l This product comes with a nationwide warranty, with a warranty period of 1 year (consumables are not covered by the warranty);
l If there are any quality issues with the product during the warranty period, free repairs will be provided (excluding improper use); Provide long-term technical support outside the warranty period, no maintenance fees will be charged, only basic accessory fees and related fees will be charged at discretion;
l For all product after-sales issues, please contact our company directly. Our after-sales service team will respond and handle them within 30 minutes.