AL-HW6010 Infrared Non dispersive CO/CO2 Two in One Analyzer
This instrument complies with the national standards of GB/T18204.2-2014 "Methods for hygiene inspection in public places" and GB/T9801-88 "Determinat
Product details

AL-HW6010Infrared non dispersiveCO/CO22-in-1 analyzer

This instrument complies with the national standards of GB/T18204.2-2014 "Methods for hygiene inspection in public places" and GB/T9801-88 "Determination of carbon monoxide in air quality - Non dispersive infrared method"; Comply with the national metrological verification regulations of JJG635-2011 "Infrared Gas Analyzer for Carbon Monoxide and Carbon Dioxide".

The main technical indicators of this instrument meet the technical requirements of national second-class instruments and can obtain a second-class calibration certificate from the Chinese Academy of Metrology. Can display PPM, mg/M ³, and%; Measurement range can be customized.

Technical advantages

Detect carbon monoxide and carbon dioxide gases in the air, as well as the temperature and humidity of the environment

Equipped with a built-in suction pump, it can suck gas from tens of meters away into the instrument for measurement

Featuring a large color touch screen and convenient and fast operation

The instrument displays three types of data: PPM, mg/M ³, and%, which can be automatically converted

Automatic zero point correction technology, convenient for users to perform zero point correction in different seasons and times

Equipped with hourly average, 8-hour average, daily average display, and storage functions

Equipped with Bluetooth wireless printing function (optional)

Main performance parameters

Resolution CO: 0.1 × 10-6 CO: 0.001%

Response time CO: t0~t90 ≤ 45S CO2: t0~t90 ≤ 15S

Measurement range CO: 0~50.0 × 10-6 or 0~200.0 × 10-6

CO2:0~0.500% or 0~1.000%

Sampling method with built-in pump suction

Repeatability ≤ 1% F · S

Zero drift ≤± 2% F · S/h

Span drift ≤± 2% F · S/3h

Linear deviation ≤± 2% F · S

Temperature additional error (between 10 ℃ and 45 ℃) ≤± 2% F · S/10 ℃

Carbon monoxide interference 1250mg/m3CO ≤± 0.3% F · S

Preheating time ≤ 30 minutes

Flow range (0.5-2.0) L/min

Digital interface RS232, equipped with data transmission software

Storage function ≤ 10000 sets of measurement data