Portable non-contact radiation thermometer
■ Compact type530series
Ideal tool for maintaining and testing production equipment and controlling food temperature
53005/53006Long focal length thermometers can safely measure objects in hazardous areas from a distance
Check the storage temperature of food during storage and transportation
Check the temperature of the food inside the store display cabinet
● InspectionHVACtemperature
● Detect faults and inspect the operation of the auto repair shop
Check the temperature of the electrical contacts on the distribution board
Check the surface temperature of moving objects
use53006on-line measurement
● ThroughUSBCommunication can continuously measure fixed points.
● FromPCPower supply can extend the measurement time limit.
● Data can be saved asCSVFormat, create simple reports, so measurement data and charts can be edited in other software.
53007/53008Portable waterproof and dustproof thermometer suitable for outdoor use and controlling food temperature
The thermometer body not only adopts a waterproof and dustproof structure (protective structure)IP67)It can be touched with wet hands and washed with water, and also uses antibacterial resin, making it an ideal choice for sanitary equipment management.
If the measured temperature exceeds the set temperature value, the upper and lower limit alarm temperature setting functions will sound a beep and have dual colorsLEDOne of the lights (red for upper limit and green for lower limit) emits an alarm. It can immediately detect abnormal temperatures without looking at the display screen, improving work efficiency.
The storage function can store up to99Record keeping is crucial for food temperature management and record keepingHACCPThe system is most effective.
530The series of high-precision portable thermometers are helpful for measurement in maintenance, detection, and environmental aspects
Control the temperature of frozen food in storage, distribution, and store display cabinets
Control the surface temperature of air conditioning, water heaters, and other equipment.
Sampling measurement of temperature during vehicle maintenance
Measure the surface temperature of the hot water drainage pipe
Measure the surface temperature of motors, blowers, boilers, etc
● Maintenance of printing machines, construction machinery, ships, trains, etc
4This model is suitable for various applications
● Wide temperature measurement range:-30~600℃
● Multi functional type, with/Lower limit alarm, variable emissivityMIN/MAXdisplay
●DScompare33:1Long-distance needle-point measurement
● ThroughUSBCommunication enables online measurement function (limited to)53006)
● Coaxial laser sighting for field of view (limited to)53005/06)
Backlight (with illuminance sensor) adopts a point saving design
Waterproof and dustproof type (limited to)53007/08)
530series 53005/53006 Specifications
|
model |
53005 |
53006 |
|
Temperature measurement range |
-30~ |
|
|
display resolution |
-30.0~ |
|
|
Measurement accuracy (ε≈)0.95) |
-30.0~ |
|
|
reproducibility |
± of reading |
|
|
Measure the field of view range |
|
|
|
detection element/wavelength |
thermopile/8~14μm |
|
|
response time |
0.5s(90%Response) |
|
|
sighting system |
Coaxial laser sighting for field of view(Class2), withPSClogo |
|
|
Data retention time |
15s |
|
|
launch/Lower limit alarm |
call the policeLEDAnd the buzzing sound |
|
|
Communication output |
none |
USB |
|
Radiation (ε) correction |
0.7/0.85/0.95switch |
0.3~1.2:0.01step |
|
Number of data records |
1 |
35(The largest)150) |
|
power supply |
Two sectionsLR6(AAalkaline)battery |
|
|
battery life |
about15Hour (under maximum load) |
|
|
Working temperature and humidity range |
0~ |
|
|
Storage temperature and humidity range |
-10~ |
|
|
external dimensions |
about182×56× |
|
|
weight |
about |
|
|
other |
|
continuous measurement |
530series 53007/53008 Specifications
|
model |
53007 |
53008 |
|
Temperature measurement range |
-30.0~ |
0~ |
|
display resolution |
± |
± |
|
Measurement accuracy (ε≈)0.95) |
-30.0~ |
0~ |
|
reproducibility |
± of reading |
± of reading |
|
Measure the field of view range |
|
|
|
detection element/wavelength |
thermopile/8~14μm |
|
|
response time |
0.7s(90%Response) |
|
|
sighting system |
No coaxial laser sighting(Class2), withPSClogo |
|
|
Data retention time |
15s |
|
|
Radiation (ε) correction |
0.95/0.85switch |
0.95/0.70switch |
|
Continuous measurement function |
(ON/OFFswitch) |
|
|
upper limit/Lower limit alarm function |
call the policeLEDAnd the buzzing sound(ON/OFFSwitching) |
|
|
Number of data records |
99 |
|
|
power supply |
1section9VAlkaline battery |
|
|
battery life |
about12Hour (under maximum load) |
|
|
Protective structure/material |
IP67(JISProtection level7)TheABS(Antibacterial) |
|
|
external dimensions |
about160×44× |
|
|
Working temperature and humidity range |
0~ |
|
|
Storage temperature and humidity range |
-10~ |
|
|
weight |
about |
|
■ Model and suffix code
|
model |
Suffix Code |
Specifications |
|
53005 |
|
-30~ |
|
53006 |
|
-30~ |
|
53007 |
|
-30~ |
|
53008 |
|
-30~ |
|
|
-E |
Choose Fahrenheit optionSW |
■ Accessories (sold separately)
|
model |
Instructions |
|
X1003B |
Black Belt Rolls (per set)2Volume) |
■ Attachment(53005/06Use)
|
model |
Instructions |
|
93017 |
soft packaging |