363D series monocrystalline silicon double flange remote transmitter
The measurement of liquid level and pressure adopts HART fieldbus technology, which can provide more on-site information to improve the performance of
Product details

performance index
The overall performance is based on the comprehensive error of reference accuracy, environmental temperature influence, and range static pressure influence.
Accuracy index
± 0.2% FS range (conventional)
Specific performance indicators
Zero based range, reference conditions, silicone oil filling, 316 stainless steel isolation diaphragm, 4-20mA analog output, digital fine adjustment value equal to the range set point value. )
accuracy
(Reference accuracy includes hysteresis, terminal based linearity, setting capability, and repeatability)
± 0.2% range
If the range is less than X
±[0.025+0.05]%
X value
Damping time constant
The total damping time constant is equal to the sum of the damping time constants of the amplifier component and the diaphragm box. The damping time constant of the amplifier component can be adjusted within the range of 0-100 seconds.
Membrane box (silicone oil)
Time constant (seconds) (can be set according to the actual situation on site, recommended 1 second)
Installation location impact
The installation position change parallel to the membrane surface will not cause zero drift. If the installation position changes more than 90 degrees from the membrane surface, zero drift within the range of 0.4KPa can be corrected by zero adjustment without affecting the range.
Power supply impact
Less than ± 0.005% range/volt
Functional indicators
Range and Sensor Limit Values
Table 1.363D Range and Sensor Limit Values
Zero point and range adjustment requirements
·The zero and range values can be set arbitrarily within the range limits indicated in Table 1.
·The range must be greater than or equal to the minimum range indicated in Table 1.
Application scenarios
Measurement occasions for liquids, gases, and vapors
output
Two line 4-20mA, users can choose linear or square root output. The digital process variable is superimposed on a 4-20mA signal and is suitable for any host using the HART protocol.
power supply
External power supply is required. The standard transmitter (4-20mA) operates at 14.5-45V DC when unloaded.
Circuit load limit
The maximum circuit resistance is determined by the external power supply voltage, and the relationship is as follows:
Note: The power supply voltage range for transmitters with backlit display screens is 14.5-45V
The power supply voltage range of intrinsic safety series transmitters is 14.5-28V
The working voltage during HART communication should be greater than 17.5V
Static pressure limit and maximum overpressure
For the 363D type, the limit value is 0psia to the flange rated value or sensor
The smaller of the rated pressure values.
Table 2.363D flange pressure rating
Fault mode
output code
If a sensor or microprocessor malfunction is detected through self diagnosis, the transmitter will drive and output a high or low alarm signal to alert the user. The alarm output value depends on the factory configuration of the transmitter:
Linear output: 3.8<I<20.8
C4: I=20.8mA fault high
CN: I=3.8mA fault low
Temperature Limit
environment
-20℃~+70℃
keep in storage
-46℃~110℃
With header: -40 ℃~85 ℃
process
At atmospheric pressure greater than or equal to, see the table below
Table 3.363D Process Temperature Limits
Humidity limit
0-100% relative humidity
Start Time
The transmitter reaches its performance indicators within 2 seconds of being powered on
Mechanical performance indicators
electrical interface
ANSI (American Standard) NPT1/2 (F) internal thread
ISO M20 × 1.5 internal thread
process interface
High pressure side: flange size (in accordance with national and chemical standards)
NP series: DN25 DN40 DN50 DN80 DN100
PN2.5 PN6 PN10 PN16 PN25 PN40
Class Series: 1 inch 1/2 inch 2 inches, 3 inches, 4 inches
150lb、300lb
Low pressure side: flange size (in accordance with national and chemical standards)
NP series: DN25 DN40 DN50 DN80 DN100
PN2.5 PN6 PN10 PN16 PN25 PN40
Class Series: 1 inch 1/2 inch 2 inches, 3 inches, 4 inches
150lb、300lb
Process liquid receiving components
Process isolation membrane: 316L stainless steel, Hastelloy C (insert tube does not have this option), tantalum (insert tube does not have this option).
Drain/exhaust valve
316 stainless steel
Process flanges and joints
316 stainless steel
363D type process liquid receiving component
Flange type process interface (transmitter high pressure side)
Process membrane, including contact surface of process gasket
316L stainless steel, Hastelloy C or tantalum
extension
316 stainless steel
mounting flange
Carbon steel galvanized or stainless steel
Low voltage side process connection (transformer low voltage side)
Isolation Diaphragm
316l stainless steel
Low pressure side flange and joint
316 stainless steel
Non liquid parts
Electronic housing
Die cast aluminum IP65
coating
Powder coating
Cover O-ring
Nitrile rubber

• Adopting MEMS monocrystalline silicon high-precision pressure sensor
Fast response speed and high stability
Measurement accuracy 0.2% FS
The maximum range ratio can reach 10:1
Adopting dual overload protection technology
• Provide standard HART bus communication mode
• Comprehensive self diagnosis and remote communication functions
LCD display with backlight and high brightness
• 360 degree rotatable on-site display screen
• Convenient on-site reset function
Convenient on-site zero and full point setting and calibration functions
Convenient on-site current circuit verification function