VIP member
10-18 high-pressure centrifugal fan
The national drum, guide, and tunnel ventilation fans look to Zibo, and Zibo looks to "Fujiang" fans. After years of effort, Fujiang fans have develop
Product details
Detailed introduction:
The national drum, guide, and tunnel ventilation fans look to Zibo, and Zibo looks to "Fujiang" fans. After years of effort, Fujiang fans have developed a streamlined equipment system in the factory, including automatic CNC cutting, hydraulic shearing machines, automatic rolling and spinning, mold pressing at the fan inlet and front plate, and electromagnetic heating for bearing installation. Each fan sold by our factory undergoes strict start-up testing before leaving the factory to ensure the effectiveness and service life of each fan.
1、 Purpose and standards
10-18 high-pressure centrifugal fan is suitable for production process equipment, iron furnaces, combustion furnaces, and positive pressure in small and medium-sized fertilizer plants
The forced ventilation of fuel boilers can be widely used for material and grain transportation. Transporting air is a non corrosive, non self igniting, and non viscous gas. Unless otherwise specified, the temperature of the medium generally does not exceed 80 ℃, and the dust content of the medium does not exceed 150 mg/m3.
This fan complies with the standard GB/T13275-91 "Technical Conditions for General Purpose Centrifugal Ventilators".
2、 Structural type
The fan is of single suction or double suction type, with a total of 17 machine numbers in the series. The ventilation fan can be made in two types: right-handed and left-handed.
Looking from one end of the motor, if the impeller rotates clockwise, it is called a clockwise cyclone machine, represented by 'clockwise', and counterclockwise, it is called a counterclockwise cyclone machine
'Reverse' represents.
The position of the air outlet of the fan is represented by the angle of the air outlet of the casing, and both 'left' and 'right' can be made at 0 °, 45 °, 90 °, 135 °
There are a total of 6 angles, 180 ° and 225 °. The transmission modes of the fan are A type, D type, and F type.
№ 4~6.3 is mainly composed of impeller, casing, air inlet, bracket, etc., while № 7.1~25 is mainly composed of impeller, casing, air inlet, etc
Composed of mouth, transmission group, etc.
⑴ Impeller: The 10-18 type fan has 6 long blades and 6 short blades. After the impeller is formed, it undergoes dynamic balance correction, resulting in smooth and reliable operation with a long service life.
⑵ Shell: Welded into a snail shell shaped integral structure with ordinary steel plates.
⑶ Air inlet: Made into a convergent streamlined overall structure, fixed to the front cover plate group with bolts.
⑷ Transmission group: composed of main shaft, bearing box, coupling, etc. The main shaft is made of high-quality steel, and the bearing box adopts an integral structure.
The D type bearing box is equipped with an oil level indicator from July 1st to 16th. The lubricating oil used is No. 30 mechanical oil, and the amount of oil added is according to the oil level mark
The requirement of ambition. Type 18~25: F is a double supported two bearing box, using rolling bearings and lubricated with bearing grease.
3、 Performance and Selection
The performance of a fan generally refers to its ability to transport gas under standard conditions. Standard atmospheric pressure pa=101325Pa, gas
Temperature t=20 ℃, relative humidity 50%, air density ρ=1.2 kg/m3.
When the usage state is non-standard, the performance of the non-standard state must be converted to the performance of the standard state, and then the fan should be selected based on the converted performance.
4、 Installation and use of fans
1. Before installation: A comprehensive inspection of all components of the fan should be conducted. Whether the components are complete, whether the rotation direction of the impeller and the casing is consistent, whether the connections of each part are tight, whether the main components such as the impeller, main shaft, and bearings are damaged, and whether the transmission group is flexible. If any problems are found, they should be repaired and adjusted immediately.
2. During installation: Pay attention to checking the casing and strictly prohibit debris and tools from falling or leaving inside the casing. On some bonding surfaces, in order to prevent
1. Before installation: A comprehensive inspection of all components of the fan should be conducted. Whether the components are complete, whether the rotation direction of the impeller and the casing is consistent, whether the connections of each part are tight, whether the main components such as the impeller, main shaft, and bearings are damaged, and whether the transmission group is flexible. If any problems are found, they should be repaired and adjusted immediately.
2. During installation: Pay attention to checking the casing and strictly prohibit debris and tools from falling or leaving inside the casing. On some bonding surfaces, in order to prevent
To prevent rust and reduce disassembly difficulties, a layer of lubricating grease or mechanical oil should be applied. The joint surface between the fan and the foundation, and the connection of the inlet and outlet air ducts should be naturally aligned, and forced connection is not allowed. It is also not allowed to add the weight of the ducts to the various components of the fan, and attention should be paid to ensuring that the fan is in a stable horizontal position.
3. Installation requirements
After installation, try pulling out the transmission group and check for any tightness or collision with the fixed parts.
(2) After installing the motor, a coupling guard (to be provided by the user) should be installed; If the intake pipe is not connected to the intake port, a protective net (to be provided by the user) should also be added.
3. Installation requirements
After installation, try pulling out the transmission group and check for any tightness or collision with the fixed parts.
(2) After installing the motor, a coupling guard (to be provided by the user) should be installed; If the intake pipe is not connected to the intake port, a protective net (to be provided by the user) should also be added.
.1.
After all installations are completed and the overall inspection is qualified, the fan can be put into trial operation.
4. Trial operation of the fan
To prevent motor overload and burnout, it is necessary to start the fan with no load (close the inlet valve and slightly open the outlet valve). If the operation is good, gradually open the valve until the specified working conditions are met. Strictly control the current during operation and do not exceed the rated value of the motor.
To prevent motor overload and burnout, it is necessary to start the fan with no load (close the inlet valve and slightly open the outlet valve). If the operation is good, gradually open the valve until the specified working conditions are met. Strictly control the current during operation and do not exceed the rated value of the motor.
The continuous operation time under rated working conditions shall not be less than 30 minutes for repair, installation, and trial operation, and for newly installed fans
Run for no less than 2 hours.
5. Operation of the fan
Before starting the fan, the following preparations should be made:
a. Close the inlet valve and slightly open the outlet valve.
b. Check the clearance dimensions of each part of the fan, and whether there is any collision or friction between the rotating and fixed parts.
When the fan starts and reaches normal speed, the bearing temperature should be checked regularly during operation to ensure it is normal
Before starting the fan, the following preparations should be made:
a. Close the inlet valve and slightly open the outlet valve.
b. Check the clearance dimensions of each part of the fan, and whether there is any collision or friction between the rotating and fixed parts.
When the fan starts and reaches normal speed, the bearing temperature should be checked regularly during operation to ensure it is normal
When there are no special requirements, the temperature rise of the bearing shall not exceed 40 ℃ of the ambient temperature; Root mean square vibration velocity value of bearing parts
Not exceeding 6.3mm/s. If abnormal phenomena such as severe vibration, impact, and rapid increase in bearing temperature are found in the fan, it is necessary to
Emergency stop.
fiveMaintenance of fans
Precautions for fan maintenance work:
1. Only operate when the fan equipment is completely normal.
2. When the fan equipment is started after maintenance, attention should be paid to whether all parts of the fan are normal.
3. Regularly remove impurities such as dust and dirt inside the fan, and prevent rusting.
4. To ensure personal safety, maintenance of the fan must be carried out while parked.
Precautions for normal operation of the secondary fan
1. If any abnormal phenomenon is found during the driving, parking or operation of the fan, it should be checked immediately. If it is a minor fault, it should be checked immediately
fiveMaintenance of fans
Precautions for fan maintenance work:
1. Only operate when the fan equipment is completely normal.
2. When the fan equipment is started after maintenance, attention should be paid to whether all parts of the fan are normal.
3. Regularly remove impurities such as dust and dirt inside the fan, and prevent rusting.
4. To ensure personal safety, maintenance of the fan must be carried out while parked.
Precautions for normal operation of the secondary fan
1. If any abnormal phenomenon is found during the driving, parking or operation of the fan, it should be checked immediately. If it is a minor fault, it should be checked immediately
We should promptly identify the cause and try to eliminate it. If a major malfunction is found, the vehicle should be stopped immediately for maintenance.
2. Except for replacing lubricants after each maintenance, lubricants should be replaced or supplemented according to the actual situation under normal circumstances.
2. Except for replacing lubricants after each maintenance, lubricants should be replaced or supplemented according to the actual situation under normal circumstances.
sixMain faults and causes of the fan
1. The fan vibrates violently
① Friction between the casing or air inlet and the impeller.
② The stiffness of the foundation is insufficient or not firm enough.
③ Loose rivets on the impeller or deformation of the impeller.
④ The impeller shaft disc hole and shaft fit are loose.
⑤ Loose connecting bolts between the casing, bearing seat and bracket, and bearing seat and bearing cover.
⑥ Poor installation of the inlet and outlet pipes of the fan leads to resonance.
⑦ There is dust, dirt, and wear on the blades, and the blades are deformed and the shaft is bent, causing the rotor to become unbalanced.
⑧ The fan shaft and motor shaft are not parallel, and the two couplings are misaligned or have no gap.
2. The temperature rise of the bearing is too high
① The bearing box vibrates violently.
② Poor quality, deterioration, insufficient filling, or impurities such as dust, sand, dirt, etc. of lubricants.
③ The tightening force of the connecting bolts between the bearing box cover and seat is too high or too low.
④ The installation of the shaft and rolling bearings is skewed, and the front and rear bearings are not concentric. .2.
⑤ Damaged rolling bearings or bent shafts.
3. Excessive motor current and high temperature rise
① The intake and exhaust pipeline gates were not closed while driving.
② The input voltage of the motor is too low or there is a single-phase power outage.
③ Affected by severe vibration of the bearing box.
1. The fan vibrates violently
① Friction between the casing or air inlet and the impeller.
② The stiffness of the foundation is insufficient or not firm enough.
③ Loose rivets on the impeller or deformation of the impeller.
④ The impeller shaft disc hole and shaft fit are loose.
⑤ Loose connecting bolts between the casing, bearing seat and bracket, and bearing seat and bearing cover.
⑥ Poor installation of the inlet and outlet pipes of the fan leads to resonance.
⑦ There is dust, dirt, and wear on the blades, and the blades are deformed and the shaft is bent, causing the rotor to become unbalanced.
⑧ The fan shaft and motor shaft are not parallel, and the two couplings are misaligned or have no gap.
2. The temperature rise of the bearing is too high
① The bearing box vibrates violently.
② Poor quality, deterioration, insufficient filling, or impurities such as dust, sand, dirt, etc. of lubricants.
③ The tightening force of the connecting bolts between the bearing box cover and seat is too high or too low.
④ The installation of the shaft and rolling bearings is skewed, and the front and rear bearings are not concentric. .2.
⑤ Damaged rolling bearings or bent shafts.
3. Excessive motor current and high temperature rise
① The intake and exhaust pipeline gates were not closed while driving.
② The input voltage of the motor is too low or there is a single-phase power outage.
③ Affected by severe vibration of the bearing box.
④ The spindle speed exceeds the rated value.
sevenOrdering Notice
The scope of supply for a complete set of single machines is: one fan; One matching electric motor; Anchor bolts: Type A transmission 1 pair, Type D
sevenOrdering Notice
The scope of supply for a complete set of single machines is: one fan; One matching electric motor; Anchor bolts: Type A transmission 1 pair, Type D
12 sets of transmission, 12 sets of F-type transmission; D. A set of F-type transmission couplings.
When placing an order, it is necessary to specify the fan's machine number, speed, flow rate, total pressure, outlet angle and rotation direction, transmission method, etc
Motor model and power.
8、 10-18 type high-pressure centrifugal tubeFan appearance and installation dimension diagram
Performance and Parts Selection Table of 10-18 High Pressure Centrifugal Fan (Continued 1)
|
machine number
|
Transmission method
|
speed
r/min
|
traffic
m3/h
|
total pressure
Pa
|
Internal efficiency
%
|
internal power
kW
|
required
power
kW
|
electric motor
|
Couplings GB/T4323-88
(One set)
|
anchor bolt
GB799-88
(4 of them)
|
|
|
model
|
Power kW
|
||||||||||
|
7.1
|
D
|
2900
|
4763
5593
6423
7252
|
13665
13724
13780
13724
|
69.1
71.5
73.3
73.8
|
25.60
28.58
32.15
36.31
|
29.4
32.9
37.0
41.8
|
Y225M-2
|
45
|
TL8型224 x65x55
55x112/65x142
|
M16x400
|
|
8082
8912
9741
10571
|
13529
13194
12734
12204
|
73.4
71.8
69.5
66.5
|
39.89
43.46
47.63
51.20
|
45.9
50.0
54.8
58.9
|
Y280S-2
|
75
|
TL8型224 x65x65
65x142/65x142
|
M20x500
|
|||
|
8
|
D
|
2900
|
6814
8001
9188
10374
|
17336
17424
17495
17424
|
69.1
71.5
73.3
73.8
|
46.49
57.90
58.39
65.95
|
53.5
59.7
67.1
75.8
|
Y280S-2
|
75
|
TL8型224 x65x65
65x142/65x142
|
M20x500
|
|
11561
12748
13935
15122
|
17176
16751
16167
15494
|
73.4
71.8
69.5
66.5
|
72.44
78.93
86.50
92.98
|
83.3
90.8
99.5
106.9
|
Y315S-2
|
110
|
TL8型224 x65x65
65x142/65x142
|
M24x630
|
|||
|
8
|
D
|
1450
|
3407
4000
4594
5187
5781
|
4334
4356
4374
4356
4294
|
69.1
71.5
73.3
73.8
73.4
|
5.81
6.49
7.30
8.24
9.06
|
6.7
7.5
8.4
9.5
10.4
|
Y160M-4
|
11
|
TL8型224 x65x42
42x112/65x142
|
M12x300
|
|
6374
6968
7561
|
4188
4042
3874
|
71.8
69.5
66.5
|
9.87
10.81
11.62
|
11.3
12.4
13.4
|
Y160L-4
|
15
|
TL8型224 x65x42
42x112/65x142
|
M12x300
|
|||
|
9
|
D
|
1450
|
4851
5696
6541
7386
|
5485
5513
5536
5513
|
69.1
71.5
73.3
73.8
|
10.47
11.69
13.15
14.86
|
12.0
13.4
15.1
17.1
|
Y180M-4
|
18.5
|
TL8型224 x65x48
48x112/65x142
|
M12x300
|
|
8231
9076
9921
10766
|
5436
5300
5115
4902
|
73.4
71.8
69.5
66.5
|
16.32
17.78
19.48
20.95
|
18.8
20.4
22.4
24.1
|
Y200L-4
|
30
|
TL8型224 x65x55
55x112/65x142
|
M16x400
|
|||
|
10
|
D
|
1450
|
6654
7813
8972
10131
|
6772
6806
6834
6806
|
69.1
71.5
73.3
73.8
|
17.74
19.80
22.27
25.16
|
20.4
22.8
25.6
28.9
|
Y200L-4
|
30
|
TL8型224 x65x55
55x112/65x142
|
M16x400
|
|
11290
12449
13609
14768
|
6710
6544
6315
6052
|
73.4
71.8
69.5
66.5
|
27.63
30.11
33.00
35.47
|
31.8
34.6
37.9
40.8
|
Y225M-4
|
45
|
TL8型224 x65x60
60x142/65x142
|
M16x400
|
|||
|
11.2
|
D
|
1450
|
9348
10977
12605
14214
|
8495
8538
8573
8538
|
69.1
71.5
73.3
73.8
|
31.26
34.89
39.25
44.34
|
35.9
40.1
45.1
51.0
|
Y250M-4
|
55
|
TL8型224 x75x65
65x142/75x142
|
M20x500
|
|
15862
17491
19119
20748
|
8416
8208
7922
7592
|
73.4
71.8
69.5
66.5
|
48.70
53.06
58.15
62.51
|
56.0
61.0
66.9
71.9
|
Y280S-4
|
75
|
TL8型224 x75x75
75x142/75x142
|
M20x500
|
|||
|
11.2
|
D
|
960
|
6189
7267
8346
9424
|
3723
3742
3748
3742
|
69.1
71.5
73.3
73.8
|
9.07
10.13
11.39
12.87
|
10.4
11.6
13.1
14.8
|
Y180L-6
|
15
|
TL8型224 x75x48
48x112/75x142
|
M12x300
|
|
10502
11580
12658
13736
|
3689
3598
3472
3328
|
73.4
71.8
69.5
66.5
|
14.13
15.40
16.88
18.14
|
16.3
17.7
19.4
20.9
|
Y200L2-6
|
22
|
TL8型224 x75x55
55x112/75x142
|
M16x400
|
|||
Performance and Parts Selection Table of 10-18 High Pressure Centrifugal Fan (Continued 2)
|
machine number
|
Transmission method
|
speed
r/min
|
traffic
m3/h
|
total pressure
Pa
|
Internal efficiency
%
|
internal power
kW
|
required
power
kW
|
electric motor
|
Couplings GB/T4323-88
(One set)
|
anchor bolt
GB799-88
(4 of them)
|
|
|
model
|
Power kW
|
||||||||||
|
12.5
|
D
|
1450
|
12996
15280
17524
19188
|
10581
10635
10678
10635
|
69.1
71.5
73.3
73.8
|
54.12
60.42
67.97
76.78
|
62.2
69.5
78.2
88.3
|
Y280M-4
|
90
|
TL9型250 x75x75
75x142/75x142
|
M20x500
|
|
22052
24315
26514
28843
|
10484
10224
9868
9457
|
73.4
71.8
69.5
66.5
|
84.33
91.88
100.70
108.25
|
97.0
105.0
115.8
124.5
|
Y315M-4
|
132
|
TL9型250 x75x80
80x175/75x142
|
M24x630
|
|||
|
12.5
|
D
|
960
|
8604
10103
11602
13101
|
4638
4662
4681
4662
|
69.1
71.5
73.3
73.8
|
15.71
17.53
19.73
22.23
|
18.1
20.2
22.7
25.6
|
Y225M-6
|
30
|
TL9型250 x75x60
60x142/75x142
|
M16x400
|
|
14600
16098
17597
19096
|
4595
4482
4325
4145
|
73.4
71.8
69.5
66.5
|
24.47
26.67
29.22
31.41
|
28.1
30.7
33.6
36.1
|
Y250M-6
|
37
|
TL9型250 x75x65
65x142/75x142
|
M20x500
|
|||
|
14
|
D
|
1450
|
18259
21439
24620
27800
|
13273
13341
13395
13341
|
69.1
71.5
73.3
73.8
|
95.38
106.48
119.79
135.31
|
109.7
122.4
137.8
155.6
|
Y315L1-4
|
160
|
TL10型315 x95x80
80x175/95x175
|
M24x630
|
|
30981
34161
37342
40522
|
13151
12825
12378
11868
|
73.4
71.8
69.5
66.5
|
148.62
161.93
177.46
190.77
|
170.9
186.2
204.1
219.4
|
Y355M2-4
|
250
|
TL10型315 x95x95
95x175/95x175
|
M24x630
|
|||
|
14
|
D
|
960
|
12089
14194
16300
18406
|
5818
5848
5871
5848
|
69.1
71.5
73.3
73.8
|
27.68
30.90
34.76
39.27
|
31.8
35.5
40.0
45.5
|
Y280S-6
|
45
|
TL9型250 x85x75
75x142/85x175
|
M20x500
|
|
20511
22617
24728
26829
|
5764
5622
5426
5200
|
73.4
71.8
69.5
66.5
|
43.13
46.99
51.50
55.36
|
49.6
54.0
59.2
63.7
|
Y315S-6
|
75
|
TL9型250 x85x80
80x175/85x175
|
M24x630
|
|||
|
16
|
D
|
1450
|
27255
32003
36750
41498
|
17336
17424
17495
17424
|
69.1
71.5
73.3
73.8
|
185.97
207.59
233.54
263.82
|
213.9
238.7
268.6
303.4
|
Y355L2-4
|
315
|
TL11型400 x95x95
95x175/95x175
|
M24x630
|
|
46245
50993
55741
66488
|
17176
16751
16167
15494
|
73.4
71.8
69.5
66.5
|
289.76
315.71
345.99
371.94
|
333.2
363.1
397.9
427.7
|
Y4002-4
(6kV)
|
400
|
TL11型400 x95x110
110x215/95x175
|
M30x800
|
|||
|
Y4003-4
|
450
|
||||||||||
|
16
|
D
|
960
|
18045
21188
24331
27474
|
7599
7638
7669
7638
|
69.1
71.5
73.3
73.8
|
53.97
60.25
67.78
76.56
|
62.1
69.3
77.9
88.0
|
Y315L1-6
|
110
|
TL10型315 x95x80
80x175/95x175
|
M24x630
|
|
30618
33761
36904
40047
|
7529
7343
7087
6792
|
73.4
71.8
69.5
66.5
|
84.09
91.62
100.41
107.94
|
96.7
105.4
115.5
124.1
|
Y355M1-6
|
160
|
TL10型315 x95x95
95x175/95x175
|
M24x630
|
|||
|
18
|
F
|
1450
|
38806
45566
52326
|
21941
22053
22142
|
69.1
71.5
73.3
|
333.12
374.09
420.85
|
385.4
430.2
484.0
|
Y4004-4
(6kV)
|
500
|
|
|
|
59086
65846
72605
79365
86125
|
22053
21739
21201
20461
19610
|
73.8
73.4
71.8
69.5
66.5
|
475.40
522.17
568.93
623.48
670.24
|
546.7
608.5
654.3
717.0
770.8
|
Y4503-4
(6kV)
|
800
|
|
|
|||
Performance and Parts Selection Table of 10-18 High Pressure Centrifugal Fan (Continued 3)
|
machine number
|
Transmission method
|
speed
r/min
|
traffic
m3/h
|
total pressure
Pa
|
Internal efficiency
%
|
internal power
kW
|
required
power
kW
|
electric motor
|
Couplings GB/T4323-88
(One set)
|
anchor bolt
GB799-88
(4 of them)
|
|
|
model
|
Power kW
|
||||||||||
|
18
|
F
|
960
|
25692
30168
34643
39119
43594
|
9617
9666
9706
9666
9529
|
69.1
71.5
73.3
73.8
73.4
|
97.25
108.56
122.13
137.87
151.94
|
111.8
124.8
140.5
158.7
174.3
|
Y355M2-6
|
185
|
|
|
|
48070
52545
57021
|
9293
8969
8596
|
71.8
69.5
66.5
|
165.11
180.94
194.51
|
189.9
208.1
223.7
|
Y355L1-6
|
220
|
|
|
|||
|
20
|
F
|
960
|
35243
41383
47522
|
11873
11934
11982
|
69.1
71.5
73.3
|
164.70
183.83
206.84
|
189.4
211.4
237.9
|
Y355L3-6
|
250
|
|
|
|
53661
59800
65039
72079
78218
|
11934
11764
11473
11073
10612
|
73.8
73.4
71.8
69.5
66.5
|
233.65
256.63
279.61
306.42
329.40
|
268.7
295.1
321.6
352.4
378.8
|
Y4005-6
(6kV)
|
400
|
|
|
|||
|
20
|
F
|
730
|
26800
31468
36136
40805
|
6866
6901
6929
6901
|
69.1
71.5
73.3
73.8
|
72.42
80.84
90.95
102.73
|
83.3
93.0
104.6
118.1
|
Y355M2-8
|
132
|
|
|
|
45473
50141
54814
59478
|
6802
6634
6402
6136
|
73.4
71.8
69.5
66.5
|
112.84
122.04
134.73
144.84
|
129.8
141.4
154.9
166.6
|
Y355L2-8
|
185
|
|
|
|||
|
22.4
|
F
|
960
|
49514
58139
66764
75389
84014
|
14893
14969
15030
14969
14756
|
69.1
71.5
73.3
73.8
73.4
|
290.26
324.01
364.51
411.76
452.26
|
330.8
372.6
419.2
473.5
520.1
|
Y4502-6
(6kV)
|
500
|
|
|
|
92640
101265
109890
|
14391
13889
13311
|
71.8
69.5
66.5
|
492.76
540.02
580.52
|
566.7
621.0
667.6
|
Y5001-6
(6kV)
|
710
|
|
|
|||
|
22.4
|
F
|
730
|
37651
44210
50769
57327
63886
|
8612
8656
8691
8656
8532
|
69.1
71.5
73.3
73.8
73.4
|
127.63
142.67
160.27
181.05
198.86
|
146.7
163.8
184.3
208.2
228.6
|
Y4004-8
(6kV)
|
250
|
|
|
|
70445
77003
83562
|
8321
8031
7697
|
71.8
69.5
66.5
|
216.66
237.44
255.24
|
249.2
273.1
293.5
|
Y4501-8
(6kV)
|
315
|
|
|
|||
|
25
|
F
|
960
|
68834
87825
92816
104806
|
18551
18646
18722
18646
|
69.1
71.5
73.3
73.8
|
502.63
561.07
631.03
713.03
|
578.0
645.3
725.9
819.9
|
Y5002-6
(6kV)
|
800
|
|
|
|
116797
128787
140778
152769
|
18381
17926
17301
16581
|
73.4
71.8
69.5
66.5
|
783.17
853.30
935.17
1005.1
|
900.6
981.3
1075.4
1156.0
|
Y5602-6
(6kV)
|
1250
|
|
|
|||
|
25
|
F
|
730
|
52343
61461
70578
79696
|
10727
10782
10825
10782
|
69.1
71.5
73.3
73.8
|
221.00
246.70
277.54
313.52
|
254.1
283.7
319.2
360.5
|
Y4502-8
(6kV)
|
355
|
|
|
|
88814
97932
107050
116158
|
10628
10365
10004
9587
|
73.4
71.8
69.5
66.5
|
344.38
375.19
411.17
442.02
|
396.0
431.5
472.0
508.0
|
Y5001-8
(6kV)
|
500
|
|
|
|||
Online inquiry