VIP member
YN194I-DX4 three-phase digital ammeter
YN194I-DX4 three-phase digital ammeter
Product details

| PRODUCT MODEL | measure | display | Peripheral functions | |||
| rs485 communication | analog output | Switching input | ALARM IN | |||
| YN194I-DX4 | Measurement: 3I | Three rows: LED | not have | not have | not have | not have |
| YN194I-DK4 | Optional | |||||
characteristic:
Measurement: Three phase current● Display: Three rows of digital tubes (LED) display STN blue screen, wide viewing angle, high-quality, high-definition LCD screen display.
Communication: RS485 communication, MODBUS-RTU protocol. It has networking communication function.
● Input: 2-channel switch input (2DI).
Output: 2-channel switch output (2DO), 3-channel analog output (3AO).
summary:
The three-phase ammeter adopts AC sampling technology for true effective value measurement, which can simultaneously measure and display the three-phase current in the power grid. It can be programmed and multiplied through panel buttons, with high cost-effectiveness. It has the characteristics of easy installation, simple wiring, easy maintenance, small engineering quantity, and on-site programmable input parameters. It can also complete network communication with different PLCs and industrial control computers in the industry.Technical indicators:
| performance | parameter | ||
| transport enter measure measure apparent show |
electric current | RATING | AC5A (other specifications, please specify when ordering) |
| overload | Overload: 1.2 times instantaneous: 10 times/10 seconds | ||
| power consumption | < 0.4VA (per phase) | ||
| impedance | >2MΩ | ||
| accuracy | RMS measurement, accuracy level 0.5 | ||
| power supply | scope of work | AC/DC85~270V | |
| power consumption | ≤5VA | ||
| output | Digital Interface | RS485, MODBUS-RTU protocol | |
| environment | work environment | -10~55℃ | |
| Environment | -20~75℃ | ||
| secure | pressure resistance | Input/power>2kV, input/output>2kV, power/output>1kV | |
| isolation | Input, output, and power supply to the chassis>50M Ω | ||
Wiring method:
Additional features:
Example of ordering:
When signing the contract, please provide detailed information such as product model, input signal, wiring method, etc. This series of products comes with a default appearance setting as standard. If customers have special requirements, please specify them in detail in other projects.Model: YN194I-DX4 (three-phase ammeter)
Input: AC5A
Communication interface: RS485/MODBUS-RTU
| Three rows |
Online inquiry