YKZ-1Applied to all industries that require rapid determination of moisture content
Suitable for intermediate and finished product testing of raw materials and samples in industries such as universities, research institutes, quality inspection agencies, pharmaceuticals, chemical enterprises, fertilizers, pesticides, dyes, coatings, food and beverage, surfactants, cosmetics, etc.
1. Gasoline, hydraulic oil, insulation oil, transformer oil, turbine oil, fire-resistant oil.
2. Pentane, hexane, dimethylbutane, octane, dodecane, eicosane, octadecane, cyclododecane, decylcyclohexane, methylbutadiene, benzene, toluene, xylene, ethyltoluene, dimethylstyrene, tetracene, petroleum ether, cyclohexylamine, methylcyclohexylamine, cycloheptane, ethylcyclohexylamine, dicyclopentadiene, dimethylnaphthalene, trimethylstyrene, biphenyl, dihydrophenanthrene, fluorene, methylethylphenanthrene, isopropylbenzene, etc.
3. Phenolic phenols, cresols, fluorophenols, chlorophenols, dichlorophenols, nitrophenols, etc
4. Ether type diethyl ether, diethylene glycol monomethyl ether, diethylene glycol diethyl ether, polyethylene glycol diethyl ether, benzyl ether, fluorophenyl ether, iodobenzene ether, didecyl ether, and diheptyl ether
5. All alcohols, all halogenated hydrocarbons, all lipids

1. Measurement range: 10ppm-100% (H2O mass fraction)
2. Moisture content resolution: 1ppm
3. Resolution of measuring tube: 0.001ml
4. Repeatability of water titration: ≤ 0.005
5. Linear correlation coefficient for water titration: ≥ 0.999
6. Capacity error ≤± 0.0002
7. Relative error ≤ 0.2%

The YKZ-1 intelligent Karl Fischer moisture analyzer comes with dedicated software that can transfer the detected data to a computer for easy organization, printing, storage, and retrieval of data.
The standard waste liquid bottle anti backflow device prevents backflow due to excessive waste liquid in the bottle, ensuring experimental safety.
The dual platinum electrode automatically determines and displays the reaction endpoint, and the termination titration design includes micro titration. The water content can be measured up to 0.001%;
Using specialized reagent bottle connectors and standard pyridine or pyridine free reagents
YKZ-1 intelligent Karl Fischer moisture analyzer adopts a large LCD display with a touch screen and an intelligent operating system. It is flexible and convenient for human-machine interaction, and can be easily operated with basic computer skills;

You can adjust the accuracy, titration speed, stirring speed, and endpoint delay according to the actual situation of the sample;

The YKZ-1 intelligent Karl Fischer moisture analyzer has rich calculation functions, and the calculation formula for each analysis method has been pre-set in the instrument. Multiple results (moisture percentage content, moisture ppm, absolute value of water content in the sample, and volume of consumed cartridge reagent) are displayed simultaneously. During the titration process, the color titration curve is dynamically displayed. It not only allows you to intuitively browse more instrument parameters and analysis result information, but also allows you to identify and determine possible side reactions at the best time to suppress them;

Once there is an error in the operation, you can immediately interrupt the experiment and restart it

ZT-1 intelligent Karl Fischer moisture analyzer automatically stores moisture content test results and can be optionally printed;

The YKZ-1 intelligent Karl Fischer moisture analyzer is equipped with a dedicated fully enclosed intelligent titration system, mainly used for stirring and changing titration solvents. You only need to operate on the touch screen without opening the reaction cup, and can use the built-in multifunctional pump to discharge waste liquid and add new solvent (methanol). This can shorten the equilibrium time, reduce the escape of organic solvents and their accumulation in the air, and protect the health and safety of you and your colleagues.


If the interval between two experiments is long (usually more than 10 days), you can also inject the remaining Karl Fischer reagent in the volumetric flask back into the reagent bottle to reduce reagent waste. This step also only requires you to operate the touch screen.

The YKZ-1 intelligent Karl Fischer moisture analyzer comes with dedicated software that can transfer the detected data to a computer for easy organization, printing, storage, and retrieval of data.
The standard waste liquid bottle anti backflow device prevents backflow due to excessive waste liquid in the bottle, ensuring experimental safety.
The dual platinum electrode automatically determines and displays the reaction endpoint, and the termination titration design includes micro titration. The water content can be measured up to 0.001%;
Using specialized reagent bottle connectors and standard pyridine or pyridine free reagents

YKZ-1High end trace moisture analyzer-Intelligent touch screen model - Karl Fischer moisture analyzer:
YKZ-1Micro moisture analyzeraccording to the standard
12、GB6238、GB11146、GB11133Waiting for over 20 national standards
Applicable standards: dozens of standards including ISO, ASTM, DIN, BS, JIS, and GB

Operation video:
(The video is currently being edited and produced)
Operation steps:
① After installing the instrument accessories according to the instructions, turn on the instrument
② Click the "Settings" button according to the instructions to select different project settings, and press the "Confirm" button to save
③ Press the "Stir" button and wait for the electrolyte to balance before using the sampler for injection
④ After injecting the sample by pressing the "Start" button, the instrument will automatically perform the test. After the test is completed, the buzzer will sound and the display screen will indicate "Test has ended"


-
One year free warranty, lifetime maintenance;
7-day no reason return and exchange, 24-hour instant response;
One on one technical guidance, allowing you to have no worries after purchasing;
National free consultation hotline: 18659285958.

| Download Materials | Update Date |
YKZ-1 Intelligent Karl Fischer Moisture Analyzer Detailed Information Introduction
|
2015-08-20 |
| Instruction manual download | Update Date |
YKZ-1 Intelligent Karl Fischer Moisture Analyzer Detailed Information Introduction
|
2015-08-20 |
| Color page download | Update Date |
YKZ-1 Intelligent Karl Fischer Moisture Analyzer Detailed Information Introduction
|
2015-08-20 |
-
-
Option 1: Customer ------->Business Manager ------->Contract Signing ------->Payment on Delivery ------->Corporate Transfer ------->Warehouse Shipment ------->Confirm Receipt ------->Our Company Invoices
Option 2: Customer ------->Business Manager ------->Contract Signing ------->Cash on Delivery ------->Warehouse Shipment ------->Express Collection ------->Confirm Receipt ------->Our Company Invoices