YC300 series programmable microcomputer relay protection device
The YC300 series programmable microcomputer relay protection measurement and control device is a set A new generation of substation automation product
Product details

The YC300 series programmable microcomputer relay protection measurement and control device is a set The new generation of substation automation products that integrate electronic technology, computer technology, power automation technology, and communication technology adopts a systematic approach The new logic programmable design has functions such as protection, measurement, control, alarm, communication, display, and waveform recording, and is the core protection and monitoring component of the intelligent switchgear. It not only has powerful functions, flexible configuration, user-friendly interface, and easy maintenance, but also has extremely strong anti-interference ability and stable and reliable performance. It can be widely used in substation automation with voltage levels of 110Kv and below. This series of devices has the following characteristics:

·Has high reliability. The components are made of industrial grade CMOS chips, and overall consideration is given to electromagnetic compatibility in chassis design, power supply design, and circuit design, with extremely strong anti-interference ability.

·

Friendly human-machine interface. Adopting a large screen graphic LCD display, the full Chinese menu can display the primary system wiring diagram, switch status, various electrical parameters, protection information, and timely and fault waveform diagrams of the protection and measurement objects on the same screen.

·

Online programming function. The PLC logic programmable function supports IE-61131-3 graphic programmable standard, and different protection control logics can be freely downloaded online to be set as comprehensive protection devices for different purposes.

·

Real time waveform display and fault recording function. It can display real-time waveforms of various phase voltages, line voltages, phase currents, and protection currents, and has the function of fault recording. It can continuously record 108 waveforms of current and voltage during faults, providing detailed data for analyzing accident causes.

·Sequential event recording function. It has 200 event recall functions, which can automatically record the occurrence time, type, and action value of events. The resolution of its time recording is less than 1ms and it has the function of not losing during power failure.

·




Multi channel status monitoring function. There are up to 16 switch input terminals, and the switch values can be freely defined. Active/passive contacts can be directly connected. 10 switch outputs, 3 optional 4-20mA analog inputs, and 1 optional 4-20mA analog output effectively solve the problem of users needing to monitor multiple battery levels and statuses without the need for additional devices.

·

Powerful communication capabilities. The front panel is equipped with one communication port (for debugging and setting), and there is one RS485 communication interface, one optional fiber optic interface, and two Ethernet interfaces at the back, which can operate simultaneously. It is suitable for various occasions to achieve remote control, remote signaling, telemetry, remote value change, remote protection for switching on and off, remote call for real-time waveform, fault recording and uploading, and other transmission functions.

·Protection setting optional function. At the factory, 8 sets of protection settings have been stored, which can be switched and selected through the panel and communication methods, quickly and conveniently adapting to various on-site operating modes.

·A comprehensive self inspection system. It has software and hardware automatic detection and alarm functions for the normal values of temperature and measurement channel coefficients of RAM, ROM, fixed values, relays, AD channels, and unit motherboards.

1

serial number

Series Name

Device model

device name

2

Application scenarios

line protection

YCL-311

4

Outgoing protection and measurement device

Protection and measurement of feeders in power systems with voltage levels of 35KV and below, as well as voltage and current protection and measurement units in 66KV and 110KV systems.

YCL-312

5

Incoming line protection measurement and control device

Protection and measurement of main power supply incoming lines in power systems with voltage levels of 110KV and below in various operating modes.

YCL-314

Mother protection measurement and control device

7

Protection and measurement of main power supply incoming lines in power systems with voltage levels of 110KV and below in various operating modes.

transformer protection

YCT-321

8

Factory transformer protection and measurement device

Protection and measurement of transformer feeders in power systems with various operating modes at voltage levels of 35KV and below.

YCT-322

9

Transformer differential protection measurement and control device

Differential protection for double coil and three coil power transformers in various operating modes of power systems with voltage levels of 110KV and below.

YCT-323

10

Transformer backup protection measurement and control device

Backup protection for power transformers in various operating modes of power systems with voltage levels of 110KV and below.

YCT-324

Transformer non electric quantity protection measurement and control device

11

Non electric quantity protection and measurement and control of power transformers in various operating modes of power systems with voltage levels of 35KV and below.

Capacitor protection

YCC-331

Capacitor protection and measurement device

12

Protection and measurement of power capacitors in various operating modes of power systems with voltage levels of 110KV and below.

automatic bus transfer

YCB-341

13

Incoming line backup automatic switching measurement and control device

Protection and measurement of backup incoming lines with automatic switching function in power systems with single busbar dual power supply and one main and one backup operation mode for voltage levels of 110KV and below.

YCB-342

14

Incoming self resetting device

Protection and measurement of backup incoming lines with automatic switching function in power systems with single busbar dual power supply and one main and one backup operation mode for voltage levels of 110KV and below.

YCB-343

Mother backup automatic measurement and control device

15

Protection and measurement of backup incoming lines with automatic switching function in power systems with single busbar dual power supply and one main and one backup operation mode for voltage levels of 110KV and below.

Motor protection

YCD-351

16

Motor protection measurement and control device

Protection and measurement and control of high-voltage asynchronous motors with voltage levels of 3-10KV.

YCD-352

Electric motor differential protection measurement and control device

18

Differential protection for large high-voltage asynchronous motors above 2000KW.

PT measurement and control

YCPT-361

PT measurement and control device

Monitoring of PT parallel/switching operation status in various operating modes of power systems with voltage levels of 110KV and below.

General measurement and control

YCM-371

Universal measurement and control device

Used for distribution cabinets that do not require protection functions and only need to measure and control the opening and closing of switches.

Basic functional configuration of YC300 series devices

Specification Model

protection function

Measurement and Control Function

communication interface

YCL-311

Outgoing protection and measurement device

Current quick break protection

Time limited current quick break protection

Timed current limiting protection

Inverse time overcurrent protection

Zero sequence overcurrent protection

Three phase primary reclosing

Post acceleration protection

Underfrequency load shedding

PT disconnection alarm

Device malfunction alarm

Control circuit disconnection alarm

Small current grounding line selection

The opening and closing of local or remote circuit breakers; 16 channel switch signal acquisition, 10 channel switch signal output; Measure and display analog quantities such as Ua, Ub, Uc, Uab, Ubc, Uca, Ia, Ib, Ic, I0, Cos Φ, f, P, Q, Pwh, Qvh, as well as telemetry functions; 2-channel pulse output, 3-channel 4-20mA analog input, 1-channel 4-20mA analog output; Accident and protection event recording function; Real time waveform display and fault recording function.

Standard configuration: 2 RS485 communication interfaces

Optional: 1 fiber optic interface

2 Ethernet interfaces

YCL-312

Incoming line protection measurement and control device

Current quick break protection

Time limited current quick break protection

Fixed time overcurrent protection

Zero sequence overcurrent protection

low voltage protection

Control circuit disconnection alarm

Device malfunction alarm

The opening and closing of local or remote circuit breakers; 16 channel switch signal acquisition, 10 channel switch signal output; Measure and display analog quantities such as Ua, Ub, Uc, Uab, Ubc, Uca, Ia, Ib, Ic, I0, Cos Φ, f, P, Q, Pwh, Qvh, as well as telemetry functions; 2-channel pulse output, 3-channel 4-20mA analog input, 1-channel 4-20mA analog output; Accident and protection event recording function; Real time waveform display and fault recording function.

Standard configuration: 2 RS485 communication interfaces

Optional: 1 fiber optic interface

2 Ethernet interfaces

YCL-313

Mother protection measurement and control device

Current quick break protection (can be set as closing quick break, low voltage lockout quick break)

Time limited current quick break protection

Fixed time overcurrent protection

Control circuit disconnection alarm

Device malfunction alarm

The opening and closing of local or remote circuit breakers; 16 channel switch signal acquisition, 10 channel switch signal output; Measure and display analog quantities such as Ua, Ub, Uc, Uab, Ubc, Uca, Ia, Ib, Ic, I0, Cos Φ, f, P, Q, Pwh, Qvh, as well as telemetry functions; 2-channel pulse output, 3-channel 4-20mA analog input, 1-channel 4-20mA analog output; Accident and protection event recording function; Real time waveform display and fault recording function.

Standard configuration: 2 RS485 communication interfaces

Optional: 1 fiber optic interface

2 Ethernet interfaces

YCT-321

Factory transformer protection and measurement device

Current quick break protection

Time limited current quick break protection

Fixed time overcurrent protection

Inverse time overcurrent protection

Zero sequence overcurrent protection

Temperature protection;

Gas protection

PT disconnection alarm

Control circuit disconnection alarm

Device malfunction alarm

Small current grounding line selection

The opening and closing of local or remote circuit breakers; 16 channel switch signal acquisition, 10 channel switch signal output; Measure and display analog quantities such as Ua, Ub, Uc, Uab, Ubc, Uca, Ia, Ib, Ic, I0, Cos Φ, f, P, Q, Pwh, Qvh, as well as telemetry functions; 2-channel pulse output, 3-channel 4-20mA analog input, 1-channel 4-20mA analog output; Accident and protection event recording function; Real time waveform display and fault recording function.

Standard configuration: 2 RS485 communication interfaces

Optional: 1 fiber optic interface

2 Ethernet interfaces

YCT-322

Transformer differential protection measurement and control device

Differential quick break protection

Ratio differential protection (second harmonic braking differential protection)

CT disconnection alarm and locking differential protection

Gas protection (body gas, loaded gas)

Main transformer oil level and temperature alarm

Device malfunction alarm

Trip circuit disconnection alarm

16 channel switch signal acquisition; 10 switch signal outputs; Measure and display analog quantities such as primary current (IA, IB, Ic), primary zero sequence current (I0h), secondary current (Ia, Ib, Ic), secondary zero sequence current (I0I), differential current (Icd1, Icd2, Icd3), braking current (Izd1, Izd2, Izd3), harmonic current (Ixb1, Ixb2, Ixb3), etc; 2-channel pulse output, 3-channel 4-20mA analog input, 1-channel 4-20mA analog output; Accident and protection event recording function; Real time waveform display and fault recording function.

Standard configuration: 2 RS485 communication interfaces

Optional: 1 fiber optic interface

2 Ethernet interfaces

YCT-323

Transformer backup protection measurement and control device

Three stage protection for blocking direction current of compound voltage (limited time quick break, overcurrent)

Zero sequence overcurrent and overvoltage protection

Gap overcurrent and overvoltage protection

overload protection

Overload lockout with on load voltage regulation

PT and CT disconnection alarm

Bus grounding alarm

Control circuit disconnection alarm

The opening and closing of local or remote circuit breakers; 16 channel switch signal acquisition, 10 channel switch signal output; Measure and display analog quantities such as Ua, Ub, Uc, Uab, Ubc, Uca, Ia, Ib, Ic, I0, Cos Φ, f, P, Q, Pwh, Qvh, as well as telemetry functions; 2-channel pulse output, 3-channel 4-20mA analog input, 1-channel 4-20mA analog output; Accident and protection event recording function; Real time waveform display and fault recording function.

Standard configuration: 2 RS485 communication interfaces

Optional: 1 fiber optic interface

2 Ethernet interfaces

YCT-324

Transformer non electric quantity protection measurement and control device

Main body heavy gas protection

Main body light gas alarm

Heavy duty gas protection

Load light gas alarm

Cooling disappearance protection

Pressure release protection

Main transformer oil level low protection

Main transformer oil temperature high alarm

16 channel switch signal acquisition, 10 channel switch signal output; 3 channels of 4-20mA analog input, 1 channel of 4-20mA analog output; Accident and protection event recording function.

Standard configuration: 2 RS485 communication interfaces

Optional: 1 fiber optic interface

2 Ethernet interfaces

YCC-331

Capacitor protection and measurement device

Current quick break protection

Timed overcurrent

Reverse timed overcurrent

low voltage protection

overvoltage protection

Zero sequence current protection

Zero sequence voltage protection

Temperature protection

PT disconnection alarm

Control circuit disconnection alarm

Device malfunction alarm

The opening and closing of local or remote circuit breakers; 16 channel switch signal acquisition, 10 channel switch signal output; Measure and display analog quantities such as Ua, Ub, Uc, Uab, Ubc, Uca, Ia, Ib, Ic, I0, Cos Φ, f, P, Q, Pwh, Qvh, as well as telemetry functions; 2-channel pulse output, 3-channel 4-20mA analog input, 1-channel 4-20mA analog output; Accident and protection event recording function; Real time waveform display and fault recording function.

Standard configuration: 2 RS485 communication interfaces

Optional: 1 fiber optic interface

2 Ethernet interfaces

YCB-341

Incoming line backup automatic switching measurement and control device

Current quick break protection

Time limited quick break protection

Timed overcurrent

inverse-time overcurrent

Incoming line backup self switching

Control circuit disconnection alarm

Device malfunction alarm

The opening and closing of local or remote circuit breakers; 16 channel switch signal acquisition, 10 channel switch signal output; Measurement display Ua、Ub、Uc、Uab、Ubc、Uca、Ia、Ib、Ic、UL、IL、CosΦ、f、p、Q、Pwh、Qvh Waiting for analog and telemetry functions; 2-channel pulse output, 3-channel 4-20mA analog input, 1-channel 4-20mA analog output; Accident and protection event recording function; Real time waveform display and fault recording function.

Standard configuration: 2 RS485 communication interfaces

Optional: 1 fiber optic interface

2 Ethernet interfaces

YCB-342

Incoming self resetting device

Current quick break protection

Time limited quick break protection

Definite time/inverse time overcurrent

Control circuit disconnection alarm

Device malfunction alarm

The opening and closing of local or remote circuit breakers; 16 channel switch signal acquisition, 10 channel switch signal output; Measurement display Ua、Ub、Uc、Uab、Ubc、Uca、Ia、Ib、Ic、UL、IL、CosΦ、f、p、Q、Pwh、Qvh Waiting for analog and telemetry functions; 2-channel pulse output, 3-channel 4-20mA analog input, 1-channel 4-20mA analog output; Accident and protection event recording function; Real time waveform display and fault recording function.

Standard configuration: 2 RS485 communication interfaces

Optional: 1 fiber optic interface

2 Ethernet interfaces

YCB-343

Mother backup automatic measurement and control device

Current quick break protection (can be set as closing quick break, low voltage lockout quick break)

Time limited quick break protection

Definite time/inverse time overcurrent

Mother backup self investment

Zero sequence voltage alarm

Control circuit disconnection alarm

Device malfunction alarm

The opening and closing of local or remote circuit breakers; 16 channel switch signal acquisition, 10 channel switch signal output; Measure and display analog and telemetry functions such as Ua1, Ub1, Uc1, Ua2, Ub2, Uc2, I-1, I-2, f, p, Q, Pwh, Qvh, etc; 2-channel pulse output, 3-channel 4-20mA analog input, 1-channel 4-20mA analog output; Accident and protection event recording function; Real time waveform display and fault recording function.

Standard configuration: 2 RS485 communication interfaces

Optional: 1 fiber optic interface

2 Ethernet interfaces

YCD-351

Motor protection measurement and control device

Current quick break protection

Timed overcurrent

inverse-time overcurrent

Zero sequence current protection

Negative sequence overcurrent protection

low voltage protection

overload protection

locked-rotor protection

Temperature protection

Control circuit disconnection alarm

Device malfunction alarm

The opening and closing of local or remote circuit breakers; 16 channel switch signal acquisition, 10 channel switch signal output; Measure and display analog quantities such as Ua, Ub, Uc, Uab, Ubc, Uca, Ia, Ib, Ic, I0, Cos Φ, f, P, Q, Pwh, Qvh, as well as telemetry functions; 2-channel pulse output, 3-channel 4-20mA analog input, 1-channel 4-20mA analog output; Accident and protection event recording function; Real time waveform display and fault recording function.

Standard configuration: 2 RS485 communication interfaces

Optional: 1 fiber optic interface

2 Ethernet interfaces

YCD-352

Electric motor differential protection measurement and control device

Differential quick break protection

Ratio differential protection (second harmonic braking ratio differential)

CT disconnection alarm and locking differential

Temperature protection

Control circuit disconnection alarm

Device malfunction alarm

16 channel switch signal acquisition, 10 channel switch signal output; Measure and display analog and telemetry functions such as primary current (IA, IB, Ic), primary zero sequence current (I0h), secondary current (Ia, Ib, Ic), secondary zero sequence current (I0I), differential current (Icd1, Icd2, Icd3), braking current (Izd1, Izd2, Izd3), harmonic current (Ixb1, Ixb2, Ixb3), etc; 2-channel pulse output, 3-channel 4-20mA analog input, 1-channel 4-20mA analog output; Accident and protection event recording function; Real time waveform display and fault recording function.

Standard configuration: 2 RS485 communication interfaces

Optional: 1 fiber optic interface

2 Ethernet interfaces

YCPT-361

PT monitoring device

overvoltage protection

Undervoltage protection

grounding protection

Zero sequence voltage alarm

PT disconnection alarm

PT switching

Device malfunction alarm

16 channel switch signal acquisition, 10 channel switch signal output; Measure and display analog and telemetry functions such as Ua, Ub, Uc, Uab, Ubc, Uca, U0, f, etc; 2-channel pulse output, 3-channel 4-20mA analog input, 1-channel 4-20mA analog output; Accident and protection event recording function; Real time waveform display and fault recording function.

Standard configuration: 2 RS485 communication interfaces

Optional: 1 fiber optic interface

2 Ethernet interfaces

YCM-371

Universal measurement and control device

Control circuit disconnection alarm