Instrument usage: Batou®XSP-8CThe three eye biological microscope adopts a large field eyepiece and an achromatic objective lens, which provides clearer and sharper imaging. This device not only allows visual observation, but also transmits the observed images to the computer screen through the camera, effectively relieving the fatigue of personnel who work for a long time. It can also conveniently save the observed images as pictures or videos, making it convenient for scientific researchers to record and archive samples Batou®XSP-8CWidely used in microbiology, cytology, bacteriology, histology, medicinal chemistry and other research institutes, it can also be used as a medical test (non clinical), such as mite detection, skin sectioning, blood analysis, etc. It can be used for various biological experiments in the laboratory and for teaching purposes in schools.
Performance characteristics: ▲ Configure large field eyepiece and achromatic objective lens,The field of view is large and clear. ▲ Coarse micro coaxial focusing mechanism,Rough movement with adjustable elasticity,Equipped with locking and limiting devices,Micro grid value:2μm. ▲ 6V 20WHalogen lamp lighting,The brightness is adjustable. ▲ The three lens barrel allows for easy switching between eyepiece observation and camera observation,100%Spectral analysis, suitable for low light photography. Optional camera system, (500Choose freely between a 10 megapixel high pixel imager or a DSLR digital camera system.
|
model |
XSP-8C |
|
brand |
|
|
eyepiece |
Broad VisionWF10X(Φ18mm)WF16X(Φ11mm) |
|
objective lens |
Achromatic color4X/0.10 |
|
Achromatic color10X/0.25 |
|
|
Achromatic color40X/0.65(spring) |
|
|
Achromatic color*100X/1.25(spring,oil) |
|
|
magnification |
Visual inspection:40X,64X,100X,160X,400X,640X,*1000X,*1600X computer:100X-2600X(Configuration)500Ten megapixel camera with screen resolution640×480In the environment) |
|
Three eye tube |
binoculars(tilt30˚Adjustable pupillary distance),100%Split beam independent camera system. |
|
focusing system |
Coarse micro coaxial focusing,Micro grid value:2Mm,Rough movement with adjustable elasticity,Equipped with locking and limiting devices,Add black plastic hand pillow board on the base |
|
converter |
four holes(Internal positioning of inward ball) |
|
stage |
Double layer mechanical mobile type(size:135mmX125mm,Mobile range: 75mmX35mm) |
|
Abbe spotlight |
N.A.1.25Adjustable up and down |
|
Color filter |
Blue filter |
|
frosted glass |
|
|
Concentrator |
Suitable for halogen lamps |
|
light source |
6V 20W,halogen lamp,The brightness is adjustable. Customizable low heat white lightLEDLighting. |
Computer type/Composition of digital system:

VType imaging system parameters: Product Model 500ten thousandUSB2.0Microscopic camera system sensor Aptina CMOS 5.1M chip size 1/2.5“ (5.70x4.28) image processor Ultra-FineTMColor Processing Engine Pixel size(um) 2.2x2.2 frame rate@resolution 5@2592x1944 18@1280x960 60@640x480 scanning mode line-by-line scanning exposure time 0.294ms~2000ms Exposure control manual/automatic white balance ROIwhite balance/manualTemp-Tintadjust Color temperature control manual/automatic Settings White balance, exposure time, noise reduction, gain, gamma, etc Operating temperature -10~ 50℃ Operating humidity 30~80%RH operating system Microsoft® Windows®XP/ Vista / 7 / 8 /10(32 & 64bit) Optical interface standardCinterface data interface USB2.0 capture/controlAPI Native C/C++, C#/VB.NET, Directshow, TwainandLabview Recording method Images and videos Cooling method* natural cooling power supply USBPlug in power supply (shared data interface)
Instrument usage: Batou®XSP-8CThe three eye biological microscope adopts a large field eyepiece and an achromatic objective lens, which provides clearer and sharper imaging. This device not only allows visual observation, but also transmits the observed images to the computer screen through the camera, effectively relieving the fatigue of personnel who work for a long time. It can also conveniently save the observed images as pictures or videos, making it convenient for scientific researchers to record and archive samples Batou®XSP-8CWidely used in microbiology, cytology, bacteriology, histology, medicinal chemistry and other research institutes, it can also be used as a medical test (non clinical), such as mite detection, skin sectioning, blood analysis, etc. It can be used for various biological experiments in the laboratory and for teaching purposes in schools.
Performance characteristics: ▲ Configure large field eyepiece and achromatic objective lens,The field of view is large and clear. ▲ Coarse micro coaxial focusing mechanism,Rough movement with adjustable elasticity,Equipped with locking and limiting devices,Micro grid value:2μm. ▲ 6V 20WHalogen lamp lighting,The brightness is adjustable. ▲ The three lens barrel allows for easy switching between eyepiece observation and camera observation,100%Spectral analysis, suitable for low light photography. Optional camera system, (500Choose freely between a 10 megapixel high pixel imager or a DSLR digital camera system.
|
model |
XSP-8C |
|
brand |
|
|
eyepiece |
Broad VisionWF10X(Φ18mm)WF16X(Φ11mm) |
|
objective lens |
Achromatic color4X/0.10 |
|
Achromatic color10X/0.25 |
|
|
Achromatic color40X/0.65(spring) |
|
|
Achromatic color*100X/1.25(spring,oil) |
|
|
magnification |
Visual inspection:40X,64X,100X,160X,400X,640X,*1000X,*1600X computer:100X-2600X(Configuration)500Ten megapixel camera with screen resolution640×480In the environment) |
|
Three eye tube |
binoculars(tilt30˚Adjustable pupillary distance),100%Split beam independent camera system. |
|
focusing system |
Coarse micro coaxial focusing,Micro grid value:2Mm,Rough movement with adjustable elasticity,Equipped with locking and limiting devices,Add black plastic hand pillow board on the base |
|
converter |
four holes(Internal positioning of inward ball) |
|
stage |
Double layer mechanical mobile type(size:135mmX125mm,Mobile range: 75mmX35mm) |
|
Abbe spotlight |
N.A.1.25Adjustable up and down |
|
Color filter |
Blue filter |
|
frosted glass |
|
|
Concentrator |
Suitable for halogen lamps |
|
light source |
6V 20W,halogen lamp,The brightness is adjustable. Customizable low heat white lightLEDLighting. |
Computer type/Composition of digital system:

VType imaging system parameters: Product Model 500ten thousandUSB2.0Microscopic camera system sensor Aptina CMOS 5.1M chip size 1/2.5“ (5.70x4.28) image processor Ultra-FineTMColor Processing Engine Pixel size(um) 2.2x2.2 frame rate@resolution 5@2592x1944 18@1280x960 60@640x480 scanning mode line-by-line scanning exposure time 0.294ms~2000ms Exposure control manual/automatic white balance ROIwhite balance/manualTemp-Tintadjust Color temperature control manual/automatic Settings White balance, exposure time, noise reduction, gain, gamma, etc Operating temperature -10~ 50℃ Operating humidity 30~80%RH operating system Microsoft® Windows®XP/ Vista / 7 / 8 /10(32 & 64bit) Optical interface standardCinterface data interface USB2.0 capture/controlAPI Native C/C++, C#/VB.NET, Directshow, TwainandLabview Recording method Images and videos Cooling method* natural cooling power supply USBPlug in power supply (shared data interface)


