Dongguan Weibang Instrument Equipment Co., Ltd
Home>Products>WBE-9099B Electronic Universal Material Testing Machine
WBE-9099B Electronic Universal Material Testing Machine
Product specification: 50KN
Product details
product details

Product Features

1 . Adopting high-precision displacement, velocity, and load closed-loop control software

2. Transmission: Adopting high-precision ball screw transmission, high efficiency, high rigidity, small deformation, and low noise.

3. Drive: Powered by Panasonic servo motors from Japan, providing stable, adjustable speed drive with high speed, low vibration, and high-speed positioning.

4. Horizontal rail material: Made of 45 # die steel through grinding and processing, with a parallel error of ≤ 0.5mm and high rigidity;

5. Guidance: Adopting chrome steel rods and four column guidance from South Korea, with excellent wear resistance and coaxiality;

6. Displacement measurement: Using a Japanese LINE high pulse (2500r/p) photoelectric encoder to measure displacement, up to 0.001mm;

7. Force measurement: Using American TRANSCELL precision tension compression explosion-proof load cell, accuracy: 0.03% F.S

8 . Control board: using self-developed 32-bit ARM chips for measurement and control, superior to the industry's 16 bit DSP processing technology, high resolution: 1/500000

9. Powerful software functions: can meet the testing of different materials, can simultaneously execute different standards, including foreign standards (with multiple standard data processing functions), units: N, kN, g, kgf, Ib, cN can be converted to each other. The experimental software designed completely according to the experimental standards has powerful functions. The experimental curve can be magnified to clearly show the amount and speed of data collection, as well as the smoothness of the curve, which can reflect the overall processing capability of hardware and software.

10. Test report and curve: The curve is accurate, the test report can be edited, and the test curve has a high degree of refinement, indicating a fast sampling frequency and a more obvious comparison with peers.


technical specifications

model

WBE-9099 series 50KN

WBE-9099B

WBE-9099A

capacity selection

1. 2, 3, 5, 10, 20, 30, 50kN come with one standard range and three optional ranges

accuracy class

B model 0.5 level/A model 1 level

Load parameters

Test force measurement range

0.2% to 100% FS (full scale)

Test force indication error

Within ± 0.5% of B model indication/within ± 1% of A model indication

Test force resolution

The maximum test force of Model B is 500000/The maximum test force of Model A is 200000,

The entire process is not divided into stages, and the resolution remains unchanged throughout the entire process

Displacement parameters

Displacement indication error

Within ± 0.2% of B model indication/within ± 0.5% of A model indication

Displacement resolution

B model 0.015 μ m/A model 0.1 μ m

control

make

join

number

Range of stress control rate

B model 0.005-5% FS/s/A model 0.05-5% FS/s

Stress control rate accuracy

When the speed of Model B is less than 0.05% FS/s, it is within ± 1% of the set value, and when the speed is greater than or equal to 0.05% FS/s, it is within ± 0.5% of the set value;

When the speed of model A is less than 0.1% FS/s, it is within ± 2% of the set value, and when the speed is greater than or equal to 0.1% FS/s, it is within ± 0.5% of the set value;

Strain control rate range

B model 0.005-5% FS/s/A model 0.05-5% FS/s

Accuracy of strain control rate

When the speed of Model B is less than 0.05% FS/s, it is within ± 1% of the set value, and when the speed is greater than or equal to 0.05% FS/s, it is within ± 0.5% of the set value;

When the speed of model A is less than 0.1% FS/s, it is within ± 2% of the set value, and when the speed is greater than or equal to 0.1% FS/s, it is within ± 0.5% of the set value;

Range of displacement control rate

0.001-500mm/min or agreed upon

0.001-300mm/min or agreed upon

0.001-300mm/min or agreed upon

Accuracy of displacement control rate

B model is within ± 0.2% of the set value/A model is within ± 0.5% of the set value

Relative error of force control rate

Within+1% of the set value for model B/within+2% of the set value for model A

Control range of constant stress, constant strain, and constant displacement

B model 0.5%~100% FS/A model 1%~100% FS

Constant stress, constant strain shape, and constant displacement control accuracy

When the set value of Model B is ≥ 10% FS, it is within ± 1% of the set value. When the set value is ≥ 10% FS, it is within ± 0.1% of the set value

When the set value of model A is ≥ 10% FS, it is within ± 2% of the set value. When the set value is ≥ 10% FS, it is within ± 0.5% of the set value

host

machine

join

number

Dimensions (length, width, height)

Approximately 980 × 750 × 1780mm

Excluding fixture testing space

1000mm (or agreed upon)

Effective experimental width

500mm (or agreed upon)

power supply

220V(50KN) 50Hz,±10%

power

1KW(50KN)

Weight

About 450KG (50KN)

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!