Hebei Emery Technology Co., Ltd
Home>Products>VOCs over limit alarm
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    15830190109
  • Address
    2F, Building 5, Zone C, Fangyi Science Park, No. 313, the Pearl River Avenue, Shijiazhuang High tech Zone, Hebei Province, China
Contact Now
VOCs over limit alarm
VOC over limit alarm, VOC over limit alarm, VOC over limit alarm device .....
Product details

The founder said

Hebei Emery Technology Co., Ltd. is engaged in the production and manufacturing of ecological environment monitoring instruments. Our main products include online dust monitoring devices and VOC over limit alarm sensing devices. Our customers are located in more than 20 provinces, cities, and districts including Shanghai, Chongqing, and Shandong. AIMOLI is committed to using advanced technology to meet the public's desire to understand environmental quality and promote social management and control of environmental quality!

project background
In order to promote the construction of ecological civilization, implement the Special Implementation Plan for the Rectification of Volatile Organic Compound Pollution in Key Industries in Hebei Province, strengthen the operation and management of volatile organic compound emission control facilities, and meet the growing demand of the people for a beautiful ecological environment. Emery Technology, in collaboration with industry elites such as the University of Science and Technology and fifty-four institutes, has carefully developed an online detection VOC over limit alarm sensor device (VOC over limit alarm) that is widely applicable to fixed pollution sources and unorganized emissions in various industries such as chemical and rubber. Intended to ensure emissions (exhaust pipes and chimneys) meet standards through improved monitoring technology.

Scope of use
The AMLVOC series VOC over limit alarm sensing device from Emery Technology is mainly used for emission sources with emission rates less than 2.5kg/h or exhaust volumes less than 60000m3/h; Especially suitable for monitoring unorganized emissions after collection and treatment; Unorganized emission workshops, factory boundaries, and other places that require excessive monitoring can retain samples for exceeding the standard.


system composition
Alarm based online monitoring system analysis host;
Gas analysis sensing device;
Gas sampling device (optional pre-processing);
Excess sample retention unit (optional);
Temperature, pressure, flow and humidity measuring instrument (optional);

Product advantages

Choosing Emery means choosing:
VOC over limit alarm that complies with national and local standards, specifications, technical requirements, and policies;
It is difficult for peers to achieve VOC over limit alarms that can be installed by enterprises in one go and reduce rectification;
The supply price is 10% lower than the average price of peers, with a lifetime free software upgrade for one investment, while peers only offer free software upgrades for one year.

System Characteristics

The product complies with VOC emission control standards for industrial enterprises in multiple provinces and cities

The entire network adopts GPRS (sending SIM card and data), unless otherwise required

Real time display of TFT-LCD industrial screen

Automatic sample retention for exceeding standards, facilitating precise laboratory analysis in the future

Adopting the original imported PID detector from Baseline Company in the United States

VOC over limit alarm detects the concentration value of VOC gas in real-time 24 hours a day

Optional explosion-proof design, can be installed in explosion-proof areas, safe and reliable

The system can use the total heat method, and the detection data is accurate and reliable

High penetration rate, with users covering more than 20 provinces, cities, and districts including Shanghai, Chongqing, and Shandong

Equipped with automatic blowing and cleaning function, extending the service life of the instrument

Equipped with automatic calibration function

Expandable optional measuring instrument for temperature, pressure, flow and humidity

Capable of storing 100000 pieces of detection data through M-BUS signal output or RS485 digital output interface

Scalable measurement collection and processing device operating status


TECHNICAL INDEX

Serial Number

Indicator Name

VOC

SO2

NOx

smoke and dust

1

Detection error (indication error)

≤±3%F.S

≤±2%F.S

≤±2%F.S

≤±10%

2

alarm error

≤± 3% F.S (The alarm setting value is generally (10-20)% F.S)

≤±3%F.S

≤±3%F.S

≤±5%

3

response time

≤30s

≤30s

≤30s

≤30s

4

repeatability

≤±2%

≤±1%F.S

≤±1%F.S

≤±2%

5

detection limit

not more thang/s

1ug/m3

1ug/m3

0.1ug/m3

6

Drift (zero and range)

≤±2%F.S/6h

≤ 1% F.S/year

≤ 1% F.S/year

≤ 1% F.S/year

7

Sensor lifespan

>1 year (using 24-hour continuous testing method)

>2 years

>2 years

>2 years













Note: Please specify if special functions such as excessive sample retention are required