Measurement principle: Using optical sensors, it can be applied to process control, water quality monitoring, and wastewater control.
Technical features:
1. Long term stable operation with zero maintenance;
2. Automatic cleaning;
3. Install and measure directly in the medium (on-site) or bypass pipeline;
4. Operate through the ZDA terminal controller and ZDA software;
sensor |
Scattering method |
light emitter |
infrared laser |
wavelength |
880nm;Pulse light source, not affected by surrounding light sources |
photodetector |
photodiode |
measuring range |
0 ~ 5000 ppm |
Best measurement range |
0 ~ 4000 ppm |
accuracy |
Reading of ±5%, or ±2ppm |
resolution |
1 ppm |
Depth of operation |
66Rice(90 psi) |
Cleaning method |
Mechanical cleaning brush |