Analytical Technology (Shenzhen) Co., Ltd
Home>Products>Touch sensitive multi parameter water quality rapid measuring instrument
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    4th Floor, Building C, Weijian Technology Industrial Park, Beihuan Road, Shiyan Street, Bao'an District, Shenzhen
Contact Now
Touch sensitive multi parameter water quality rapid measuring instrument
Instrument Description: The touch sensitive multi parameter water quality rapid measuring instrument adopts a 7-inch full touch screen, flat icon desi
Product details
Instrument Introduction

The YC-9100 touch sensitive multi parameter water quality rapid measuring instrument is designed and developed based on relevant national standards. It adopts a 7-inch full touch screen, flat icon design, guided operating system, and simple and easy to understand interface, allowing operators to use it quickly and accurately.The detection system adopts an independent multi module optical (imported) design with excellent optical performance. The operation does not require manual intervention, and the system automatically identifies the detection channel for precise detection. Adopting a 16mm digestion detection integrated optical colorimetric tube simplifies the operation steps, avoids errors caused by repeated liquid removal, and greatly improves accuracy.


Technical Parameter


Testing items

COD

Ammonia nitrogen

total phosphorus

total nitrogen

turbidity

Suspended solids (SS)

Model name

YC9100touchMulti parameter water quality rapid measuring instrument

Testing standards

HJ/T399-2007

HJ535-2009

GB1183-89

EPAColor changing acid method

Determination of turbidity in water quality

Improvement of National Standard Weight Method

Range of measurement

0-15000mg/L

0-50mg/L

0-20mg/L

0-100 mg/L

0-1000NTU

0-500mg/L

limit of detection

5mg/L

0.01mg/L

0.02mg/L

0.5mg/L

0.5mg/L

5mg/L

Dissolve the environment

165℃,20min

No need to dissolve

125℃,30min

125℃,30min

No need to dissolve

No need to dissolve

Testing items

total chromium

hexavalent chromium

copper

zinc

nickel

iron

Testing standards

GB7466-87

GB7467-87

bco

Xylenol orange method

GB11910-89

HJ/T345-2007

Range of measurement

0-5mg/L

0-5mg/L

0-50mg/L

0-15mg/L

0-4mg/L

0-50mg/L

limit of detection

0.001

0.001

0.01

0.02

0.009

0.004

Measurement Error

≤± 5

repeatability

≤±3%

Optical stability

≤±0.001A/20Minutes(100000Hour without decay)

Colorimetric method

Colorimetric tube (digestion colorimetric integrated tube)

transmission mode

USBLocal Area Network

Printing method

Built in thermal printer

display

7Inch color touch screen

Operation interface

Touchscreen Chinese/English (optional)

Power supply mode

AC(220V±10%)50Hz

Storage

3Ten thousand records96Curve (supports customization)

power

5W

work environment

5-45 85%No condensation

Host size

348mm*250mm*145mm

Instrument weight

host<2.6kg; Dissolver<7kg

The following projectsYC9100 Touch sensitiveAll parameters of the rapid water quality analyzer are measurable

Serial Number

Measuring Item

Measurement range(mg/L

limit of detection

Serial Number

Measuring Item

Measurement range(mg/L

limit of detection

1

COD

0-10000

5

17

phosphate

0-20

0.02

2

Mn methodCOD

0-10

0.1

18

sulfate

0-200

5

3

Ammonia nitrogen

0-50

0.05

19

sulfide

0-4mg/L

0.01

4

total phosphorus

0-20

0.02

20

cyanide

0-1

0.004

5

total nitrogen

0-100

0.5

21

fluoride

0-10

0.02

6

turbidity

0-1000NTU

0.5

22

nitrate nitrogen

0-20

0.5

7

Suspended solids(SS

0-500

5

23

nitrite

0-1

0.002

8

chroma

0-500linear measure

5

24

Residual chlorine

0-10

0.1

9

hexavalent chromium

0-5

0.01

25

total chlorine

0-10

0.1

10

chromium

0-5

0.01

26

chlorine dioxide

0-10

0.05

11

copper

0-50

0.05

27

silica

0-5

0.1

12

nickel

0-4

0.1

28

Volatile phenol

0-10

0.1

13
zinc 0-15 0.05 29 manganese 0-5 0.04
14 silver 0-1 0.05 30 arsenic 0-0.5 0.005

15

iron

0-50

0.01

31

aniline

0-2

0.02

16 antimony 0-10 0.5 32 PH 0-12 0.01


Technical parameters of digestion instrument


Dissolve sample size

25branch

time display

Real time date and time display

Operation interface

Chinese display

operating mode

Touch-tone

rated voltage

AC 220V±10%/50Hz

Power requirements

grounding

Dissolve pore size/depth

16mm/65mm

Dissolving capacity

>12mL

display screen

TFTHigh definition color screen

timing error

10min±0.1s

Pre set digestion mode

CODTotal phosphorus, total nitrogen

Dissolution method

Fully enclosed type

safety protection

Double protection against overheating

temperature control

intelligencePIDtemperature control

custom mode

5The temperature and time can be set arbitrarily

Project switching

Quick switch

Reminder method

buzzer

Alarm prompt1

Reaching the specified temperature and maintaining a constant temperature

Custom time

5-999minadjustable

Alarm prompt2

Dissolve completed and stop heating

Custom Temperature

90~200℃ adjustable

Dissolve protection

Heat shield/shield

Temp Accuracy

<±0.5

Temperature control sensor

Imported PlatinumPT100

heating rate

Set to165℃,12Constant within minutes

Instrument weight

6kg

work environment

-10-40℃, relative humidity<85%

External dimensions

230*340*130mm


Example of operating interface

Instrument characteristics

1. Full touch design: 7-inch touch screen, supporting Chinese/English display (optional), guided operating system, simple and time-saving.

2. Wide detection range: dozens of detection parameters can be expanded, and customized according to customer needs.

3. Detection optics: Adopting independent multi module optical (imported) design, excellent optical performance, stable and reliable.

4. Operating System: Guided operating system with a simple and easy to understand interface, guiding users to complete operations quickly and accurately.

5. Operating program: a. Built in system program and user program, which can add frequently tested items to the user program for easy searching.

b. It has power-off protection function and one click factory reset function to prevent data loss.

c. The built-in standard work program can be used directly, and users can also expand the detection items themselves.

d. Built in help interface, which can query user detection process problems and issues.

e. It has a one click factory reset function, which can quickly recover data loss in case of unexpected situations.

6. Intelligent detection: Standard measurement and continuous measurement can be switched freely, reducing repeated measurement steps and improving detection efficiency.

7. Operation safety: Adopting a digestion colorimetric integrated tube, reducing the steps of transferring reagents, making the measurement simple, fast, and safe.

8. Quick printing: Equipped with a built-in thermal printer, it can print both current and historical measurement data.

9. Data storage: Standard working curve and 96 user-defined items, capable of storing 30000 pieces of detection data.

10. Online function: Supports data transfer between network port, LAN, USB and PC or printer.

11. Professional reagents: specialized reagents, simplified operating procedures, reduced operational errors, less reagent usage, and lower consumable prices.



Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!