TEROS 12 Soil Moisture, Temperature, and Conductivity Sensor Measurement System
The latest rapid conductivity measurement method
Product details

TEROS 12 Soil Moisture, Temperature, and Conductivity SensorIt's original5TE、Upgraded version of GS3TEROS12 soil moisture, temperature, and conductivity sensors combine accuracy, economy, ease of use, and reliability. The TEROS 12 sensor can be connected to METER's latest data acquisition, such as ZL6, enabling plug and play of sensors and cloud storage management of data.

main features

   Simultaneously measuring soil volumetric moisture content(EWC)、 Conductivity and temperature

   The latest rapid conductivity measurement method

   Thermistor embedded with intermediate probe

   Total moisture measurement range——Sensitive sensing of subtle changes in moisture content within the range of 0~100% VWC

   The frequency of use is70MHz capacitor technology minimizes the impact of salt and texture as much as possible

   Special stainless steel probe for easy insertion into various soils and good contact

   Epoxy resin filling ensures field burialover 10 years

   Suitable for various data acquisition, and the voltage output is easy to read


TECHNICAL INDEX

Measurement indicators

Volume Moisture Content (VWC)

Apparent dielectric constant ε a

temperature

conductivity

range

Mineral soil calibration: 0.00~0.62 m3/m3

Non soil medium calibration: 0.0~1.0 m3/m3

1 (air)~80 (water)

-40~60℃

0 - 10 dS/m

resolution

0.001 m3/m3

0.1℃

0.001 dS/m

accuracy

Typical mineral soil universal calibration: ± 0.03 m3/m3 In (± 3.00% VWC),
When the conductivity of soil solution is less than 8 dS/m;

Special calibration in any porous medium: ± 0.01-0.02 m3/m3 (± 1-2% VWC).

±1εa @1-40 (soil range);
15% of the measured value @ 40~80

±1℃

±5%

sensor type

Frequency domain principle

——

——


Size:9.4 cm x 2.4 cm x 7.5 cm  Support data collection (purchased separately)METER's ZL6, EM50/60 series); Other data acquisition systems that provide 4.0~15VDC power supply and support serial communication or SDI-12 communication

  Probe length:5.5 cm

  Work environment:-40~60 ℃ (sensors available for use in higher or lower environments, please contact us if needed)

  Cable length:standard5m. Other lengths can be customized, up to a maximum of 75m.

  Type of connector:3.5mm headphone plug or bare wire connector

  Measurement volume:1010 cm³

  Measurement time:25-150 ms (milliseconds)

  Supply Voltage(VCC) to GND:minimum4.0 VDC; Typical: NA; maximum 15.0 VDC

  Digital input voltage(High logic): Minimum:2.8V; Typical 3.6V; Maximum: 3.9V

  Digital input voltage(Low logic): Minimum:-0.3V; Typical 0.0V; Maximum: 0.8V

  Digital input voltage(High logic):minimum:NA; Typical: 3.6V; Maximum: NA

  Power line conversion rate: Minimum1.0V/ms; Typical: NA; Maximum: NA

  electric current25 second measurement period: minimum 3.0mA; typical 3.6mA; maximum 16.0mA; static waiting period: minimum NA; typical 0.03mA; maximum NA

  Start TimeDDI serial port: minimum 80ms; typical NA; maximum 100ms; SDI-12: minimum NA; typical 245ms; maximum NA

  Following standards:exist Production under ISO 9001:2015 standard; EM ISO/IEC 17050:2010 (CE marking); 2014/30/EU and 2011/65/EU; EN61326-1:2013 and EN55022/CISPR 22

  electric current25 second measurement period: 3.0~16.0mA, typical 3.6mA; static waiting period: typical 0.03mA

  Start TimeDDI serial port 80-100ms; SDI-12 typical 245ms


  Origin and Manufacturer: United StatesMETER Corporation (Former Decagon)