●Large screen, large font. It can display important parameters such as test results, test frequency, temperature, and temperature coefficient simultaneously.
●The design of unique temperature compensation and automatic calibration methods makes instrument operation more concise and reliable.
●It has environmental temperature and material temperature coefficient settings to ensure the accuracy of measuring the conductivity values of materials with different temperature coefficients, making it very suitable for material research institutions and higher education institutions.
●With a lifting compensation of up to 0.5mm, it can be used to measure workpieces containing non-conductive thin layers such as paint and plastic film.
●The measurement range is 0.51-112% IACS or 0.3-65MS/m, covering all non-ferrous metal materials.
●Built in data storage, capable of recording16 thousandThe group test data and important test parameters can be connected to a computer to generate a complete report.
● Two measurement units (MS/m or% IACS) are convenient to choose from, and the resistivity indication can also be directly switched on the measurement interface
●The detection probe has interchangeability, and users can replace the probe provided by our company without matching.
●Beautiful appearance, easy to carry and grip. Easy and convenient to use.
●The backlight lighting design facilitates reading detection data in low light conditions.
●Three language options: Simplified Chinese, Japanese, and English.
Tags:& Nbsp   Xiamen Tianyan Instrument Co., Ltd.  Eddy Current Conductivity Meter  Eddy Current Conductivity Meter  Metal Conductivity Meter
PRODUCT MODEL project |
Sigma 2008 A |
Operating Frequency |
60 KHz sine wave |
Conductivity measurement range |
0.51% IACS to 112% IACS or 0.3 MS/m to 65 MS/m or resistivity 0.01538 Ω• mm ²/m to 3.33333 Ω• mm ²/m |
resolution |
0.01% IACS (when less than 51% IACS); 0.1% IACS (range from 51% IACS to 110% IACS) |
measurement accuracy |
Measurement value ± 1% (temperature range 0 ℃~50 ℃), measurement value ± 0.5% (temperature range 20 ℃) |
lift off |
500μm |
temperature measurement |
0 ℃ to+50 ℃ (accuracy up to 0.5 ℃) |
Automatic compensation function |
The conductivity measurement result is automatically corrected to a value of 20 ℃ |
Normal working environment |
Temperature 0 ℃ to+50 ℃, relative humidity 0 to 95% |
display |
Large screen LCD with backlight The screen displays multiple important parameters simultaneously |
power supply |
High performance lithium-ion rechargeable batteries |
probe |
Equipped with a probe with a diameter of ¢ 14 mm and a working frequency of 60 KHz |
Reading memory |
Can be saved16 thousandGroup measurement data file |
PCMachine communication method |
RS 232 serial port |
Weight |
0.5KG (including battery) |
Host size |
220 mm×95 mm×55 mm |
Instrument housing |
High impact resistant and waterproof engineering plastic shell |
Packaging and Protection |
High impact resistance, portable carrying case, containing instruments, probes, communication cables, operation manual, conductivity indicator block, charger, USB flash drive |
attachment |
Three conductivity standard test blocks are randomly selected, and more standard test blocks can be provided for users to choose from |
Tags:& Nbsp   Xiamen Tianyan Instrument Co., Ltd.  Eddy Current Conductivity Meter  Eddy Current Conductivity Meter  Metal Conductivity Meter
●Measurement of electrical conductivity and resistivity of non ferromagnetic materials
●Determine the degree of heat treatment
●Check for thermal damage, material fatigue, and cracks
●Determine metal purity
●Monitor metal uniformity
●Metal classification
●Monitor strength and hardness
●Detecting the density of powder metallurgy parts
Tags:& Nbsp   Xiamen Tianyan Instrument Co., Ltd.  Eddy Current Conductivity Meter  Eddy Current Conductivity Meter  Metal Conductivity Meter
Eddy current conductivity tester technical support 1: 0592-3195306 /
Contact: Mr. Cai
Eddy current conductivity tester technical support 2: 0592-3195308 /
Contact: Trainer
Tags:& Nbsp   Xiamen Tianyan Instrument Co., Ltd.  Eddy Current Conductivity Meter  Eddy Current Conductivity Meter  Metal Conductivity Meter
Product Selection Guide Download: Sigma 2008 Series Product Selection Guide
SigmaA/B/CComparison of Main Indicators of Series Eddy Current Conductors
project model |
measuring range |
Withdrawal compensation |
Operating Frequency |
Measure area |
Surface testing |
temperature compensation |
Store data |
measurement accuracy |
Sigma 2008B |
0.51%~112%IACS(full scale) |
0.5mm |
60KHzand 500KHz |
minimum8mmSmall area and thin strip |
With curvature compensation |
Three types of automatic compensation Same temperature and non same temperature(Automatic and manual input) |
500Group data and upload to computer |
Measurement value ±0.5% |
Sigma 2008B1 |
60KHz |
minimum14mm |
project model |
measuring range |
Withdrawal compensation |
Operating Frequency |
Measure area |
Surface testing |
temperature compensation |
Store data |
measurement accuracy |
Sigma 2008A |
0.51%~112%IACS(full scale) |
0.5mm |
60KHz |
minimum14mm |
not have |
Two types of automatic compensation for same temperature and non same temperature(Manual input) |
500Group data and upload to computer |
Measurement value ±0.5% |
Sigma 2008A1 |
7.76~112%IACS |
project model |
measuring range |
Withdrawal compensation |
Operating Frequency |
Measure area |
Surface testing |
temperature compensation |
Store data |
measurement accuracy |
Sigma 2008C |
0.51%~112%IACS(full scale) |
0.1mm |
60KHz |
minimum14mm |
not have |
Single temperature compensation Isotherm |
500Group data and upload to computer |
Measurement value ±1% |
Sigma 2008C1 |
7.76~112%IACS |
not have |
1measuring range
A/B/B1/CtypeThe measurement range is wide, and in addition to commonly used copper and copper alloys, aluminum and aluminum alloys, it can also test low conductivity non-ferrous metals such as titanium and stainless steel. It is the only true full range instrument in China, which does not require separate purchase of high conductivity and low conductivity instruments. One instrument is equivalent to two other instruments for others.
IIWithdrawal compensation
Lift off compensation is an important indicator of eddy current conductivity meter, which refers to the ability of the instrument to overcome the thickness of non-conductive coatings (such as coatings, paints, etc.) on the tested object,A/A1/B/B1typeLike similar instruments abroad, it is also the only instrument in China with a lifting compensation of up to 0.5mm. Even if there are other impurities such as coatings or paints and uneven surfaces on the surface of the measured workpiece, as long as it does not exceed 0.5mm, it can ensure measurement accuracy.
IIIOperating Frequency
At present, the commonly used working frequencies are 60KHz and 500KHz. 60KHz is the standard for conductivity testing in the aviation industry, while 500KHz can only be used to measure the conductivity value of thin plate materials.BtypeIt is the only instrument in China that comes with high and low frequency dual probes, with a high-frequency probe frequency of up to 500KHz. The high-frequency probe can test ultra-thin workpieces ranging from 0.1mm to 0.3mm, so there is no need to worry about even the thinnest workpieces.
4Measure area
The diameter of the eddy current conductivity meter probe is generally between 13 and 14mm.BtypeEquipped with dual probes of different sizes, the diameter of the small probe can reach up to 8mm, and the probe adopts electromagnetic shielding technology. The measured object does not need to be larger than twice the size of the probe, and it can measure ultra small workpieces as small as 8mm, which can also be easily handled.
5Measuring surfaces and rapid sorting
BtypeThere is a unique curvature correction technology, a dedicated surface measurement mode, and a "∧" - shaped probe cover attached, which can also stably measure surface materials. andBtypeIt has continuous measurement function and can quickly sort materials by setting upper and lower limit alarms, achieving the highest work efficiency.
VItemperature compensation
Domestic instruments only have virtual temperature compensation mode, and accurate measurements can only be made when the calibration block is at the same temperature as the measured material.BType machineAdopting advanced German technology, it is the only instrument in China with true automatic temperature compensation, which can automatically compensate to the standard value even when the standard block and the measured material are at different temperatures.
7Store data
All models can store 500 sets of data and can be set to automatic storage without affecting operation speed. It is convenient to view test records at any time, eliminating the inconvenience of notes and reducing manual error rates. Except for the C1 type, it can be connected to a computer to transfer data for printing and organizing.
8measurement accuracy
Each modelThe indicator functions are different, but no compromise is made on the most critical measurement accuracy of the instrument. The accuracy of all models is as high as ± 0.5%~± 1%, which is the same as the highest standard of similar foreign instruments, ensuring the most accurate measurement results.
9Measurement parameters
Each modelThe instruments all have three measurement parameters, namely conductivity MS/m, conductivity% IACS, and resistivity Ω· mm ²/m. One click switching does not require manual conversion and is extremely convenient to use.
Tags:& Nbsp   Xiamen Tianyan Instrument Co., Ltd.  Eddy Current Conductivity Meter  Eddy Current Conductivity Meter  Metal Conductivity Meter