Advanced horizontal heating graphite furnace design The domestic use of transverse heating graphite furnace for atomic absorption has achieved uniform temperature distribution of graphite tubes, reducing chemical interference and memory effects. This not only ensures improved atomization efficiency but also extends the service life of graphite tubes, ensuring analysis accuracy.
Highly automated products have extraordinary performance: coupled with the powerful analysis assistant AAWin2.0 software, the operation is more accurate and simple. Adopting an eight lamp automatic switching turret and pre-set optimized working conditions for hollow cathode lamps, it can facilitate multi-element detection; Automatic flow setting, automatic ignition, automatic shutdown protection; Automatically adjust negative high voltage and lamp current, and balance the two paths of light energy automatically; Automatically set flame height and atomizer position, select analysis conditions to ensure reliable analysis results; Automatic conversion of spectral bandwidth, available in five levels: 0.1nm, 0.2nm, 0.4nm, 1.0nm, and 2.0nm; Automatic wavelength scanning and peak searching; Automatically set gas flow rate, select element analysis * fuel assist ratio; When using the deuterium lamp to fasten the background, it automatically switches to the semi transparent and semi reflective mirror device, and can also make angle adjustments to ensure the coincidence of the two light spots and the effect of fastening the background; Expandable flame automatic sampler, graphite furnace automatic sampler, hydride generator, laughing gas control box, cooling circulating water device.
Reliable security protection system: adopting multiple security protection measures to ensure the safety of operators.
Reliable position recognition: equipped with combustion head installation detection and drainage level detection, ensuring * protection for operators during flame combustion.
Comprehensive graphite furnace protection measures: Simultaneously detect the pressure of the protective gas and the flow rate of the cooling water. In case of abnormal fluctuations, immediately stop heating and sound an alarm.
Cooling water flow monitor: Ensure sufficient cold water flow to cool the furnace body before heating the graphite furnace.
Real time flame monitoring: The flame monitor monitors changes in the flame at any time. When an unexpected power outage or incorrect operation causes the flame to extinguish, the acetylene gas circuit will immediately shut down automatically and prompt an alarm.
Acetylene leakage protection system: 24-hour monitoring of the acetylene concentration inside the instrument and in the working environment. Once the acetylene exceeds the warning concentration, the acetylene gas path will automatically close and an alarm will be prompted. (Acetylene leakage cannot start the machine)
Real time monitoring of abnormal pressure: When using air acetylene flame analysis, the air pressure monitor constantly monitors changes in air pressure. When an abnormal situation occurs, the acetylene gas circuit will immediately shut down automatically and prompt an alarm.
Excellent scalability: It can easily and quickly respond to diverse and complex sample analysis systems, easily meeting your various analysis needs.
ASC-900 Atomic Absorption Flame Automatic Sample Injector: TAS-990 series atomic absorption spectrophotometer flame method detection automatic sample injection accessory, the main functions include automatic cleaning and zero calibration; Automatic sampling (60 sample cups, 8 standard sample cups).
ASC-900 Graphite Furnace Automatic Sample Injector: TAS-990 series atomic absorption spectrophotometer graphite furnace detection automatic sample injection accessory, the main functions include automatic cleaning, sample dilution, and automatic addition of 1-6 matrix improvers (70 sample cups).
Laughing gas device: used in conjunction with a flame type atomic absorption spectrophotometer.
Automatic air compressor: used in conjunction with flame type atomic absorption spectrophotometer.
Automatic temperature control cooling circulating water device: used in conjunction with graphite furnace type atomic absorption spectrophotometer, the cooling water is recycled and reused, saving water and reducing measurement costs.
The most reliable software assistant - AAwin2.0 ◇ Diverse operating environments: Fully supports the Windows system platform. ◇ Simple human-machine dialogue Measurement element setting wizard: 1. Use the wizard to set the measurement elements;
Automatically complete the switching and peak searching of 8 element lights;
Automatically input optimized working parameters and analysis conditions, or manually input various working parameters and conditions to control the instrument to automatically complete the settings.
Automated instrument control function:
1. Implement automatic conversion between flame atomizers and graphite furnace atomizers;
2. Automatic wavelength peak searching;
3. The flame height, position, and gas flow rate can be fine tuned;
4. The automatic energy balance function makes operation more convenient, and the wavelength correction function makes the wavelength more accurate
Fully supports automatic sampler: can set up flame and graphite furnace automatic samplers;
An automatic sampler can be used to automatically complete the measurement during the measurement process;
The graphite furnace automatic sampler can mix and inject samples.
◇Sichuan TAS-986 Atomic Absorption SpectrophotometerPowerful features
Provide two types of background clipping methods: self absorption clipping background and deuterium lamp clipping background, to make the analysis results more accurate.
During graphite furnace analysis, the screen displays the entire process information, including measurement values, temperature, program, time, etc., and saves all measured signal curves and temperature curves within the integration time for users to access and print.
Automatic fitting of standard curves.
Dynamic display of measurement data.
The data instruments used in the analysis and testing process include detection and post-processing functions for "concentration, absorbance, standard deviation, and relative standard deviation". The quality control function is more effective when used in conjunction with an automatic sampler.
Accurate sample measurement: Using a guide to set up the sample;
The calibration method and curve equation can be chosen by oneself;
Blank calibration measurement can be performed on the sample;
The sensitivity correction function makes the measurement results more realistic and accurate.
◇Sichuan TAS-986 Atomic Absorption SpectrophotometerConvenient data export
Print output: Provide a summary of reports for single element and multi-element analysis.
The measurement results can be printed;
Can print the peak seeking curve;
Can print the measurement curve;
Can print standard curves;
The instrument conditions can be printed.
Data export: The data export function enables data sharing with other systems.
The measurement results can be saved in Microsoft Word format, Microsoft Excel format, or text format
File format
|