Product Features
ladoptSWRTechnical measurement of moisture content, insensitive to temperature and salt content, ensuring data accuracymeasurement accuracy
lSynchronous measurement, soil moisture, soil conductivity, soil temperature
lOutput parameters: soil temperature, soil moisture content, soil conductivity, real part of dielectric constant, real part of dielectric constant (temperature compensation), imaginary part of dielectric constant, imaginary part of dielectric constant (temperature compensation), temperature corrected soil conductivity
lInstantaneous response of sensors
lNo calibration required
lCompact and durable structure, no maintenance required
Technical Specifications
lWorking temperature range:-40℃~55℃
lStorage temperature range:-40℃~70℃
lMeasurement range of dielectric constant:1~75Accuracy: ±1.5%Or ±0.5Choose the largest of the two
lSoil moisture measurement range: from completely dry to saturated, accuracy:±0.03Moisture volume content
lConductivity measurement range:0~1.5S/m, ±3%Or ±0.03 S/mChoose the maximum between the two
lTemperature measurement range:-40~55℃, temperature accuracy: ±0.3℃
lCommunication port:SDI-12(Maximum communication distance)60Rice)
lWorking voltage:9~20VDC,
lmerit Consumption: Standby:1mA,Work:10mA
Waterproof performance: able to withstand continuous complete immersion
lmaterial Material:PVCand316stainless steel
lline Cable: UV resistant, can be directly buried
lCable length:5Mi,10Rice and other options are available