Instrument usage:
Batou® RSM-30VThe series of weld penetration microscopes, converted by photoelectric technology, are suitable for detecting various types of overlap, welding, and other fusion depths. Compare and measure the weld penetration depth, width, and other data of different welded seams to verify their quality. Depth of fusion refers to the depth at which the base metal or previous weld seam melts on the cross-section of a welded joint. The microstructure of the area between the base metal and the weld seam, where the same material but different materials are connected together by welding, is called the welding penetration depth. The quality and comprehensive mechanical properties, mechanical properties, failure, etc. of the welded product are closely related to the size of the welding penetration depth.
RSM-30V The continuous welding penetration microscope can visually display the observed object on a computer when observing it. This series of instruments has the advantages of strong stereoscopic effect, clear and wide imaging, long working distance, and a wide range of applications.
This series of melting depth measurement microscopes is easy to operate, intuitive, and has high calibration efficiency, suitable for inspection and measurement of melting depth industrial production lines. It can also be used for the inspection of welding defects (printing misalignment, edge collapse, etc.) that occur in printed circuit components, and for single boardsPCVerification and vacuum fluorescence display screenVFDVerification and so on. Equipped with our independently developed penetration measurement software, we can accurately measure various data.
Technical parameters:
|
Model specifications |
RSM-30 |
|
eyepiece |
WF10X (Φ20mm) |
|
objective |
Variable magnification range0.7X~4.5X |
|
Visual magnification factor |
7X~45X |
|
Computer magnification factor |
10X-90XThe testing environment is suitable for configuration500Ten thousand pixel imaging system,640x480When it comes to resolution. If the image resolution is adjusted, the corresponding multiplier will change. ) |
|
Optical zoom |
1:6.5 |
|
Field of view range |
Ø28.6mm~ø4.4mm(Visual inspection with eyepiece) |
|
work distance |
95mm |
|
optical system |
Internal oblique light path zoom system, body view angle13°45Tilt observation |
|
Distance between pupils of both eyes |
55-75mm |
|
Circular tray diameter |
Ø95mmOrganic glass andØ95mmBlack and white glass panel |
|
Illumination |
Upper light source:LEDAdjustable brightness of white light side illumination Lower light source:LEDAdjustable brightness of white light side illumination |
|
base size |
205x275x40mm |
|
Base focusing stroke |
106mm |
|
voltage |
Wide voltage design110V-240V |
measuring softwareBT-2000MMain functions:
Graphic measurement: points, lines, rectangles, circles, ellipses, arcs, polygons.
Measurement of graphic relationships: distance between two points, distance from a point to a straight line, angle between two lines, and relationship between two circles.
Element construction: midpoint construction, center point construction, intersection construction, perpendicular construction, external tangent construction, internal tangent construction, chord construction.
Graphic presets: points, lines, rectangles, circles, ellipses, arcs.
Graphic processing: changing graphic size, moving graphic position, and digitizing graphic modifications.
Image processing: image capture, image file opening, image file saving, image printing
System composition:
Computer Type(RSM-30V) 1Microscope2Adapting glasses3Camera(USB)4Two dimensional measurement softwareBT-2000M
Imaging system parameters:
|
PRODUCT MODEL |
500ten thousandUSB2.0Microscopic camera system |
|
sensor |
Aptina CMOS 5.1M |
|
Chip Size |
1/2.5“ (5.70x4.28) |
|
image processor |
Ultra-FineTMColor Processing Engine |
|
Pixel size(um) |
2.2x2.2 |
|
Frame rate@resolution |
5@2592x1944 |
|
18@1280x960 |
|
|
60@640x480 |
|
|
SCAN |
progressive scanning |
|
time of exposure |
0.294ms~2000ms |
|
Exposure Control |
hand movement/automatic |
|
white balance |
ROIwhite balance/hand movementTemp-Tintadjust |
|
Color temperature control |
hand movement/automatic |
|
set up |
White balance, exposure time, noise reduction, gain, gamma, etc |
|
operate temperature |
-10~ 50℃ |
|
Operating humidity |
30~80%RH |
|
operating system |
Microsoft ® Windows ® XP/ Vista / 7 / 8 /10(32 & 64position) |
|
optical interface |
standardCinterface |
|
data interface |
USB2.0 |
|
capture/controlAPI |
Native C/C++, C#/VB.NET, Directshow, TwainandLabview |
|
Record Mode |
Images and videos |
|
Cooling method* |
natural cooling |
|
power supply |
USBPlug in power supply (shared data interface) |
Instrument usage: Batou® RSM-30VThe series of weld penetration microscopes, converted by photoelectric technology, are suitable for detecting various types of overlap, welding, and other fusion depths. Compare and measure the weld penetration depth, width, and other data of different welded seams to verify their quality. Depth of fusion refers to the depth at which the base metal or previous weld seam melts on the cross-section of a welded joint. The microstructure of the area between the base metal and the weld seam, where the same material but different materials are connected together by welding, is called the welding penetration depth. The quality and comprehensive mechanical properties, mechanical properties, failure, etc. of the welded product are closely related to the size of the welding penetration depth. RSM-30V The continuous welding penetration microscope can visually display the observed object on a computer when observing it. This series of instruments has the advantages of strong stereoscopic effect, clear and wide imaging, long working distance, and a wide range of applications. This series of melting depth measurement microscopes is easy to operate, intuitive, and has high calibration efficiency, suitable for inspection and measurement of melting depth industrial production lines. It can also be used for the inspection of welding defects (printing misalignment, edge collapse, etc.) that occur in printed circuit components, and for single boardsPCVerification and vacuum fluorescence display screenVFDVerification and so on. Equipped with our independently developed penetration measurement software, we can accurately measure various data.
Technical parameters:
Model specifications RSM-30 eyepiece WF10X (Φ20mm) objective Variable magnification range0.7X~4.5X Visual magnification factor 7X~45X Computer magnification factor 10X-90XThe testing environment is suitable for configuration500Ten thousand pixel imaging system,640x480When it comes to resolution. If the image resolution is adjusted, the corresponding multiplier will change. ) Optical zoom 1:6.5 Field of view range Ø28.6mm~ø4.4mm(Visual inspection with eyepiece) work distance 95mm optical system Internal oblique light path zoom system, body view angle13°45Tilt observation Distance between pupils of both eyes 55-75mm Circular tray diameter Ø95mmOrganic glass andØ95mmBlack and white glass panel Illumination Upper light source:LEDAdjustable brightness of white light side illumination Lower light source:LEDAdjustable brightness of white light side illumination base size 205x275x40mm Base focusing stroke 106mm voltage Wide voltage design110V-240V
measuring softwareBT-2000MMain functions:
Graphic measurement: points, lines, rectangles, circles, ellipses, arcs, polygons.
Measurement of graphic relationships: distance between two points, distance from a point to a straight line, angle between two lines, and relationship between two circles.
Element construction: midpoint construction, center point construction, intersection construction, perpendicular construction, external tangent construction, internal tangent construction, chord construction.
Graphic presets: points, lines, rectangles, circles, ellipses, arcs.
Graphic processing: changing graphic size, moving graphic position, and digitizing graphic modifications.
Image processing: image capture, image file opening, image file saving, image printing
System composition:
Computer Type(RSM-30V) 1Microscope2Adapting glasses3Camera(USB)4Two dimensional measurement softwareBT-2000M
Imaging system parameters:
|
PRODUCT MODEL |
500ten thousandUSB2.0Microscopic camera system |
|
sensor |
Aptina CMOS 5.1M |
|
Chip Size |
1/2.5“ (5.70x4.28) |
|
image processor |
Ultra-FineTMColor Processing Engine |
|
Pixel size(um) |
2.2x2.2 |
|
Frame rate@resolution |
5@2592x1944 |
|
18@1280x960 |
|
|
60@640x480 |
|
|
SCAN |
progressive scanning |
|
time of exposure |
0.294ms~2000ms |
|
Exposure Control |
hand movement/automatic |
|
white balance |
ROIwhite balance/hand movementTemp-Tintadjust |
|
Color temperature control |
hand movement/automatic |
|
set up |
White balance, exposure time, noise reduction, gain, gamma, etc |
|
operate temperature |
-10~ 50℃ |
|
Operating humidity |
30~80%RH |
|
operating system |
Microsoft ® Windows ® XP/ Vista / 7 / 8 /10(32 & 64position) |
|
optical interface |
standardCinterface |
|
data interface |
USB2.0 |
|
capture/controlAPI |
Native C/C++, C#/VB.NET, Directshow, TwainandLabview |
|
Record Mode |
Images and videos |
|
Cooling method* |
natural cooling |
|
power supply |
USBPlug in power supply (shared data interface) |