Quality System Certification Combination Air Conditioning Unit
Hello, the manufacturer supplies a combination air conditioning unit with a wide quality system certification! Shanghai Zhaokuo Purification Equipment
Product details

The manufacturer supplies a combination air conditioning unit with wide quality system certification

Hello! Shanghai Zhaokuo Purification Equipment Co., Ltd. specializes in the production ofZKKThe air conditioning purification series products have been certified by the quality system, and we offer higher cost-effectiveness compared to our peers in the same class,Our service is more guaranteed at the same price Contact: Ms. Cheng Longmei, Fax:,, Email:zhaokuo188@163.com
Website: Zhaokuo Official Chinese and English Website: http://www.zzkfilter.com
http://www.zhaokuo.net

Chengxin Tong International English Website:http://www.zhaokuo.cn
Chengxin Tong Shop:http://www.zhaokuo.com.cn

ZZK-KTXSeries combination air conditioning unit

Overview

Produced by our factoryZZK-KTXThe series combination air conditioning unit is designed according toGB/T14294Designed and developed according to the national standard for modular air conditioning units. With functional segments as the combination unit, it can be arbitrarily segmented and combined according to actual needs, with diverse functions that can meet the needs of air purification and regulation systems in various industries. This product is suitable for comfort air conditioning in large and medium-sized public buildings such as sports halls, hospitals, office buildings, restaurants, as well as industrial air conditioning in textile, chemical fiber, cigarette, electronic instrument, pharmaceutical and other industries with special requirements for air treatment.KTXThe series of products is a new generation of products that have been improved based on years of design, manufacturing, and application. This product not only retains all the advantages of the original series of products, but also makes significant improvements to multiple technologies and process structures. At the same time, it adds new technologies that have not yet been applied in the original series. Therefore, this product is an ideal product with more advanced technology, more complete structure, and simpler operation and use.

KTXIntroduction to each functional section of the series air conditioning unit

Various specifications of air conditioning units have the following functions, which can be combined and selected by design units and users according to their needs. At the same time, non-standard air conditioning unit design and manufacturing can be carried out according to user needs. 1New return air mixing section The position of the new return air outlet can be set at the end, top, or left and right sides according to the design requirements. If it is inconsistent with this sample, the specific opening position should be provided. A regulating valve can be installed on the new return air outlet, and the actuator has three types: manual, electric, and pneumatic, which can be selected by the user. 2Filter section There are two types of primary and medium efficiency filters, equipped with diamond shaped bag and four peak bag, and can also be equipped with automatic winding. The filter material is made of high-quality polyester non-woven fabric, and the filter adopts a quick installation and removal mechanism, a cover display and alarm device. 3New exhaust section (also known as flat top split air mixing section) This section of the box is equipped with a primary return air valve, with one exhaust and one fresh air outlet on the top of the box before and after the valve, and equipped with a regulating valve. Its function is to supply air conditioning units with partial return air when there is a return air fan, so that the fresh air is mixed with the primary return air in the required proportion; When using a DC system during the transition season, the return air valve should be closed once, and the exhaust and fresh air valves should be fully opened. 4Energy recovery section Used for cross split air mixing and exhaust energy recovery in dual fan systems. There is a return air valve inside this section of the box, and the top is an energy recovery device. It is a device that uses the cold (hot) exhaust air to indirectly cool (heat) the fresh air. The fresh air passes through a plate type energy recovery device and can recover the sensible heat energy of the exhaust air60%about. At the same time, the exhaust and fresh air do not come into direct contact, making it particularly suitable for energy recovery in DC air conditioning systems that eliminate harmful gases indoors. When used in a DC system, the return air valve should be closed once. A separate exhaust system should be installed in places with highly toxic gases, and this section should not be used. 5Middle section (maintenance section) This section is used for the connection of the transition section and the internal maintenance lighting of the unit. Before the filtering section, a middle section must be set up before and after the surface cooling section, heating section, and silencing section. 6Secondary return air section The middle section connected to the secondary return air pipe can be equipped with a regulating valve at the top, which is equipped with manual, electric or pneumatic adjustment mechanisms. Users can choose from this section, which can also be combined with the supply fan section. 7Cold section on the surface The surface cooler adopts a structure of four, six, and eight rows of copper tubes with aluminum foil in series. The aluminum foil is in the form of double flanged corrugated edges, reducing the use of large bent tube heat exchangers60%The welding elbow of the heat exchanger improves the heat exchange power, and the advanced mechanical expansion tube form ensures the contact performance of the heat exchanger. The heat exchanger is divided into fixed and rotary types, and users can choose one according to their needs. The heat medium used is steam or hot water. 8Watering section There are two forms of single-stage two row and single-stage three row, and this section is equipped with streamlined designABSFlame retardant plastic air deflectors and water blocking plates are used, and new energy-saving nozzles are used for the nozzles. At the same time, according to user requirements, fiberglass water tanks or stainless steel water tanks can be used. Due to the use of a double-layer panel and double-layer door structure in this section, it not only prevents the phenomenon of air conditioner panel leakage in the spray section, but also has a beautiful appearance.

KTXCharacteristics of air conditioning unit products: Generally, the main unit adopts a steel frame structure. If the user requests an aluminum alloy frame and a color plate panel, it must be specified when ordering. If there are special requirements, special sizes, and colors, they can be made according to the user's requirements. Various specifications of air conditioning units have multiple functions mentioned above, which can be combined and selected by design units and users according to their needs. At the same time, non-standard air conditioning unit design and manufacturing can be carried out according to user needs.ZZK-KTXParameters and product features of modular air conditioning units:air volume2000~260000m3/h ZKSeries combination air conditioner, Widely used in machinery, electronicsInstruments, precision machineryHousehold appliancesMetallurgy, chemical industry, textile and synthetic fibersChemical fiber, textile Weaving, printing, medicine and healthcare, foodPurification air conditioning projects in industries such as tobacco are also applicable to high-rise buildingsRadio and television Science and Technology Museum, Exhibition HallComfortable air conditioning engineering for large and medium-sized public buildings such as sports centers, hotels, restaurants, cinemas, and shopping mallsIndustrial and civil building air conditioning engineering.

The factory has a research and development department, equipped with professional engineers who can draw drawings and design products for customers for free according to their needs. Your satisfaction is our greatest joy!