Dongguan Beituo Electromechanical Co., Ltd
Home>Products>Power frequency spark machine 30KV
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    18924378066
  • Address
    Beizha Xifang Industrial Zone, Humen Town, Dongguan City
Contact Now
Power frequency spark machine 30KV
Power frequency spark machine 30KV
Product details
 1. Overview
The 30KV power frequency spark machine is a professional instrument for testing insulation and leak detection, suitable for online insulation detection of wires and cables. It can detect defects such as pinholes, air gaps, cracks, etc. that are not visible to the naked eye in the insulation cover layer of wires and cables. It has defect recording, sound and light alarm, and trigger relay control to stop the wire collection system.
  2. Model and workplace
● Input voltage: AC220V、 Ground wire (R live wire, N neutral wire, ground wire, three core cable)
Test wire diameter: φ 1.0~φ 16mm, (wire diameters or cable trays above φ 16mm can be customized)
● Alarm mode: manual, automatic
● Detection line speed: 450m/min
● Guide wheel: 60mm plastic steel
Copper bead: diameter 4.5mm x 80mm long
● Safety precautions: The entire equipment must be connected in series with a ground wire
Power supply: 200-240V AC 50/60HZ
● Environmental temperature:- 5℃~50℃
Relative humidity: 20% to 85%
Power consumption: ≤ 500W
● Precautions: Reliable grounding!
  3. VolumeVolume of power frequency spark machine (W × H × L): 802 × 382 × 850-1050mm
Please connect the standard ground wire in series with the ground wire!!
  4. Pre use inspection
1. Power input 220V, ground wire
2. Confirm safe grounding
3. Adjust the center height
4 Turn on the power regulating potentiometer to zero, adjust the required high voltage value after normal production, and use the ground wire to detect whether the alarm is normal within a certain time
5. After the machine alarms, it is in the automatic reset state
When the machine alarms manually, press the reset button to return the high voltage to the original set value
Please do not touch the test cable during the testing process!
  5. MaintenanceEnsure long-term cleanliness of the body and regularly check the glossiness of the copper beads.
Please replace the copper ball and guide wheel immediately if they are damaged.
Fault and solution: No alarm when testing cable defects
Either side of the tested cable must maintain communication with the series ground wire
B high voltage needs to be adjusted to above 1000V
C body series grounding wire
Is the high-voltage line connection between the upper and lower boxes correct
(2) No high voltage output
A fuse is blown
Is the high voltage indicator light on when starting high voltage
The lid on the upper box is not properly closed
After starting, the relay inside the electrical box does not work
  7. Other faults
(3) The above problems are all normal. If any of the above problems occur, the electronic control board needs to be checked
(4) After starting the high voltage, it is in an alarm state. Check the high voltage transformer
Attached: power cord, instruction manual
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!