overview
|
The NHR-1100 series simple single loop digital display controller adopts a modular structure scheme, with a simple structure and easy operation, suitable for industries such as plastics, food, and packaging machinery.
|
|
|
instrument panel
|
|
|
|
|
|
| 160 * 80mm (Type A) |
80 * 160mm (Type B) |
96 * 96mm (Type C) |
96 * 48mm (D-type) |
48 * 96mm (E-type) |
|
|
|
| 72 * 72mm (F-type) |
48 * 48mm (H-type) |
|
|
Parameter function
|
|
|
| Note: The above parameters are all parameters of the instrument. If it is not a fully functional instrument, the parameters corresponding to the unselected function will not be displayed. |
|
|
|
Instrument wiring diagram
|
|
The specifications and dimensions are A, B, C, D, and E-type wiring diagrams Note: The direction of the wiring terminals on the back cover of the horizontal and vertical instruments is different, as shown in schematic diagram 1. |
 Figure 1
|
|
|
|
|
 The specification size is F-type wiring diagram
|
|
|
 The specification size is H-shaped wiring diagram |
| ★ Note: In the above wiring diagram, if different functions are marked on the same group of terminals, only one function can be selected. If the RS485 communication function and the transmission output function are on the same set of OUT terminals, only one can be selected. |
|
|
|
instrument selection
|
NHR-1100□-□-□/□/□( )-□-( ) ① ② ③ ④ ⑤ ⑥ ⑦
|
| ① Specification and size |
② Enter the division number |
| code |
Width * Height * Depth |
code |
Dividing number (measurement range) |
A B C D E F H |
160 * 80 * 110mm (horizontal) 80 * 160 * 110mm (vertical) 96 * 96 * 110mm (Method) 96 * 48 * 110mm (horizontal) 48 * 96 * 110mm (vertical) 72 * 72 * 110mm (Method) 48 * 48 * 110mm (Method) |
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
55 |
Thermocouple B (400-1800 ℃) Thermocouple S (0-1600 ℃) Thermocouple K (0-1300 ℃) Thermocouple E division (0-1000 ℃) Thermocouple T division (-200.0-400.0 ℃) Thermocouple J division (0-1200 ℃) Thermocouple R scale (0-1600 ℃) Thermocouple N division (0-1300 ℃) Thermocouple F2 division (700-2000 ℃) Thermocouple Wre3-25 division (0-2300 ℃) Thermocouple Wre5-26 division (0-2300 ℃) Thermal resistance CU50 (-50.0-150.0 ℃) Thermal resistance CU53 (-50.0-150.0 ℃) Thermal resistance CU100 (-50.0-150.0 ℃) Thermal resistance PT100 (-200.0~650.0 ℃) Thermal resistance BA1 (-200.0.0~600.0 ℃) Thermal resistance BA2 (-200.0-600.0 ℃) Linear resistance 0-500 Ω (-1999~9999) Remote transmission resistance 0-350 Ω (-1999~9999) Remote transmission resistor 30-350 Ω (-1999~9999) 0~20mV (-1999~9999) 0~40mV (-1999~9999) 0~100mV (-1999~9999) Internal retention Internal retention 0~20mA (-1999~9999) 0~10mA (-1999~9999) 4~20mA (-1999~9999) 0~5V (-1999~9999) 1~5V (-1999~9999) Internal retention 0-10V (-1999~9999) (non switchable) 0-10mA square root (-1999~9999) 4-20mA square root (-1999~9999) 0-5V square root (-1999~9999) 1-5V square root (-1999~9999) Full switch |
| ③ Output (OUT) |
| code |
Output type (load resistance RL) |
X
0
1
2
3
4
5 D1 |
no-output 4-20mA(RL≤600Ω) 1-5V(RL≥250KΩ) 0-10mA(RL≤1.2KΩ) 0-5V(RL≥250KΩ) 0-20mA(RL≤600Ω) 0-10V(RL≥4KΩ) RS-485 communication interface (Modbus) |
| ④ Alarm (relay contact output) |
| code |
Alarm limit |
X
1
2 |
no-output 1-limit alarm 2-limit alarm |
| ⑤ Feed output |
| code |
Feed output (output voltage) |
X P |
no-output Feed output As "P (24)" indicates a power output of 24V. |
| ⑥ Power supply |
| code |
Voltage range |
A D |
AC/DC100~240V(50/60Hz) DC 20~29V |
| ⑦ Remarks |
| No remarks can be omitted |
|
| remarks: |
|
1. Adopting a short-circuit free ring design, users do not need to open the casing when switching signals; If the user does not specify the products that require short-circuit rings, they will be shipped as 1100 products. 2. When selecting, please refer to the wiring diagram to choose the function. Due to the small size of instrument wiring terminals, they may not have full functionality, and some functions can only be selected from one of them on the same group of terminals. 3. When writing the model, it must be complete, and any function items that have not been selected cannot be omitted and must be supplemented with an "X". Example 1: NHR-1100A-02-0/2/P (24) - A Example 2: NHR-1100C-27-0/X/X-D
|