Multy8320 Multi Parameter Water Quality Analyzer (SF Express Free Shipping) Product Introduction

Model: Single channel ODEON Multy 8310
Dual channel ODEON Multy 8320
Dual channel ODEON Multy 8330
Dual channel ODEON Multy 8340
Manufacturer: PONSEL, France
Origin: France
2、 Detailed Performance Description
1. 4-inch large screen display, rich content, can display pH, temperature, electrode/battery status, current atmospheric pressure, etc
2. Built in recorder, capable of recording up to 100000 sets of data
3. Self testing, automatic diagnosis of status and calibration
4. Automatic reading, stable testing, accurate, and good reproducibility
5. Automatic temperature compensation
6. Can be connected to any electrode with a single parameter, or to a three in one composite probe
7. Can simultaneously detect parameters such as pH/ORT, dissolved oxygen/saturation, conductivity/salinity, turbidity, water temperature, etc
Multy8320 Multi Parameter Water Quality Analyzer (SF Express Free Shipping) Electrode parameters
model |
Single parameter |
multi-parameter |
|||||
pH/ORP/T |
dissolved oxygen |
conductivity |
Turbidity/suspended solids
|
single channel |
dual-channel |
||
|
electrode
|
PH electrode |
X |
X |
X |
|||
dissolved oxygen electrode |
X |
X |
X |
||||
Conductivity electrode |
X |
X |
X |
||||
Turbidity electrode |
X |
X |
X |
||||
Multi parameter probe |
X |
X |
|||||
Photometer probe |
X |
X |
|||||
number of channels |
1 |
2 |
|||||
digital technology |
Single parameter can be upgraded to multi parameter |
Single/dual channel multi parameter |
|||||
memory |
100000 sets of data (including sample ID, user ID, time and date) .) |
||||||
data management |
Compliant with GLP standards |
||||||
ID |
Sample, project, user: Character table, * 10 more words, 20 users |
||||||
Reading/Recording |
3 modes: manual, interval, continuous |
||||||
Electrode status indication |
yes |
||||||
Automatic diagnostic function |
yes |
||||||
display screen |
LCD 4 'inch backlit display, 240 x 320. Equipped with automatic economy mode switching Display time and date, user, sample, ° C, status, pressure Simultaneously display 1 to 7 measurement parameters (* multiple) |
||||||
power supply |
4 AA rechargeable batteries (charger required) |
||||||
runtime |
2000 hours of standard battery (in economy mode) |
||||||
interface |
-USB -RS 485 interface (1 or 2 electrodes) -External 12V or charger |
||||||
shell |
PC/ABS |
||||||
Size - Weight |
196 x 121x 46 mm - 400 g |
||||||
Protection level |
Outdoor design, IP67, waterproof |
||||||
Operating Temperature |
-10 to+60 ° C |
||||||
Storage temperature |
-25 to+65 ° C |
||||||
Operating Humidity |
> 80% |
||||||
By purchasing a PHOTOPOD photometer probe, you can upgrade to a multifunctional water quality analyzer that can test over 50 parameters including COD, ammonia nitrogen, total phosphorus, total nitrogen, phosphate, sulfate ions, nitrate, nitrite, residual chlorine, hexavalent chromium, Al, Cu, Fe, Mn, Mo, Zn, and more.
4、 Digital electrode capable of accepting single parameters
(1) Dissolved oxygen OPTOD ® Fluorescence measurement technology
1. No need for calibration, no need for membrane, no need for electrode solution, no drift
2. There is no cross effect on pH 1-14, CO2, H2S, SO2
3. Real time temperature, salinity, and air pressure compensation
4. Quick response
5. No O2 consumption: precise display of ultra-low concentration
6. Complies with ASTM D 888-05 international analytical standard
(2) Turbidity: Infrared turbidity measurement method 0-4000 NTU; 0-4500 mg/L
1. Infrared Sensor - Optical Technology
2. Accurate measurement
3. Can be calibrated as mg/L
4. No sampling required - direct measurement
5. ISO 7027 standard
(3)pH/ORP
1. PH/ORP/T integrated electrode
2 PONSEL 'PLASTOGEL' ® Gel electrolyte technology
3. Automatic temperature compensation
4. Sturdy electrode body
5. High cost-effectiveness: pH/ORP Cartridge replaceable module technology
(4) Conductivity PONSEL C4E
1. Conductivity/salinity/temperature sensors
2. 4-electrode conductivity design
3. Automatic temperature compensation
4. Durable and sturdy
5. No maintenance required
5、 Technical parameters
electrode |
pH/ORP T |
Dissolved oxygen/T |
Conductivity/T |
Turbidity/T |
|
application |
Laboratory and field |
Laboratory and field |
Laboratory and field |
Laboratory and field |
|
compatibility |
Drinking water, sewage treatment, seawater, rivers, Natural water bodies . |
Drinking water, sewage treatment, seawater, rivers, natural water bodies . |
Drinking water, sewage treatment, seawater, rivers, natural water bodies . |
Drinking water, sewage treatment, seawater, rivers, natural water bodies . |
|
sensor |
pH, ORP, temperature |
OPTOD, temperature |
Conductivity, salinity, temperature |
Turbidity, temperature |
|
Size (D x L) |
23 x 159 mm |
25 x 146 mm |
27 x 177 mm |
27 x 170 mm |
|
Standard cable length |
3 m |
3 m |
3 m |
3 m |
|
Weight (3m cable) |
350 g |
450 g |
350g |
300 g |
|
protection level |
IP68 |
IP68 |
IP68 |
IP68 |
|
Operating temperature |
-10°C – 50°C |
-10°C – 50°C |
-10°C – 50°C |
-10°C – 50°C |
|
temperature sensor |
CTN |
CTN |
CTN |
CTN |
|
communication interface |
Modbus RS 485 |
Modbus RS 485 |
Modbus RS 485 |
Modbus RS 485 |
|
material |
PVC |
Inox 316 L |
PVC |
PVC PMMA |
|
Replacement parts |
pH/ORP Cartridge |
DODisc ® |
- |
- |
|
Shelf life of electronic devices |
2 years |
2 years |
2 years |
2 years |
|
parameter |
pH |
ORP |
dissolved oxygen |
Conductivity, salinity |
turbidity |
measurement range |
0,00 – 14,00 pH |
-1000,0 mV +1000,0 mV |
0,00 – 20,00 mg/L
0 – 200% SAT |
4 ranges 0-200,0 µS/cm 0-2000 µS/cm 0,00-20,00 mS/cm 0,0-200,0 mS/cm |
0 - 4000 NTU 4 ranges: 0,0 – 50,0 NTU 0,0 – 200,0 NTU 0 – 1000 NTU 0 – 4000 NTU |
Range selection |
- |
- |
- |
Automatic |
Automatic |
resolution |
0,01 pH |
0,1 mV |
0,01 mg/L 1%SAT |
0,01 to 1 µ/mS/cm |
0,1 to 1 NTU mg/L |
precision |
± 0,1 pH |
± 1 mV |
± 0,1 mg/L ± 0,1 % |
± 1% (full scale) |
± 1% (full scale) |
compensation |
temperature |
- |
Air pressure, temperature, salinity (Mode: Off, Manual, Auto) |
temperature |
temperature |
Measuring principle |
PONSEL 'PLASTOGEL'® Gel electrolyte Ag/AgCl reference electrode |
Platinum electrode Ag/AgCl reference electrode |
PONSEL OPTOD® fluorescence method ASTM D888-05 standard |
4-electrode conductivity technology (2 platinum electrodes and 2 graphite electrodes) |
90 ° infrared technology ISO 7027 standard |
|
Response time t90 Full process: 0-99% |
< 5 s |
< 5 s |
< 1 s |
< 5 s |
< 5 s |
6、 Standard configuration
host |
1 ODEON Classic, Open or X-type (including 4 AA batteries) |
electrode |
1, 2, 3 or 4 digital PONSEL sensors (3-meter cable) |
charger |
1 230 V charger |
ODEON PC cable |
1 item |
Standard liquid |
125 mL standard solution (depending on specific parameters) |
suitcase |
Outdoor plastic carrying case, shockproof and waterproof, lightweight; Can accommodate 2 electrodes, PC connection cable, charger, and 4 bottles of standard solution (125 ml) |
PC software |
Wintek Viewer |
7、 Attachment/Optional
Standard solution (125 mL):
pH: 4,01-7,01-10,01 ORP : 240 mV
Conductivity: 84 µ S/cm, 1413 µ S/cm, and 12880 µ S/cm/
Turbidity: Formazine
Electrode cable length: 7 m/15 m (can also be customized)
Portable case
Software: WINTEK
ODION Upgrade: Classic to Open
12V external power supply