Lora wireless concentrator
2020-10-12

Overview: The intelligent meter reading control management system is designed to improve the comprehensive billing management level of water, electricity, gas, and heat. It replaces traditional manual meter reading methods with fully automatic meter reading methods. Compared with similar meter reading systems, it has the characteristics of adaptive network structure, no debugging, no maintenance, stable operation, and easy expansion. The system adopts advanced wireless network data transmission technology to real-time collect the usage status of residents' water, electricity, gas, and heat, realizing centralized storage and unified management of data, reducing manual labor, greatly improving work efficiency, and providing a basis for relevant departments to manage, statistics, and analyze energy usage, making management more scientific and efficient.
The intelligent meter reading control management system consists of four parts: comprehensive meter reading management system software, concentrator, collector, and intelligent meter. The concentrators include GPRS concentrators, telephone line concentrators, and Ethernet concentrators, with the main difference being their upstream communication method. The downstream communication method is compatible with all collectors. The collectors include M-bus collector, RS485 collector, and wireless collector. Smart meters include M-bus meters, RS485 energy meters, wireless remote transmission meters, and various IC card meters with the above remote communication interfaces.
In the meter reading system, the concentrator automatically reads back and stores all the meter data it manages, while receiving control commands from the management center and forwarding them to the meters. This system has excellent compatibility and scalability, which can achieve both the management of one type of smart meter and the comprehensive management of multiple types of smart meters such as water, electricity, gas, and heat. Performance characteristics: Modular functional design. The concentrator adopts an embedded module with R1610C as the core, and is equipped with resources such as serial port, Ethernet port, clock, etc. Modular design of various functions, stable and reliable operation, and easy expansion. Connect socket number and socket type. Main function description: CN2 RJ45 10M/100M compatible with Ethernet interface CN11 SIM LOCK SIM card socket. When using GPRS, install SIM card JP1 2-core SIP and select working mode (working mode or debugging mode). The data storage is stable and reliable. The concentrator adopts a 32M large capacity memory, which has fast data storage and query speed. Support sector balancing, long service life, and data retention for more than 10 years after power failure. The fully automatic function design concentrator automatically maintains the communication link of subordinate devices, achieves data collection automatically, and does not require manual intervention. The concentrator has watchdog and power detection functions to ensure long-term stable operation. Usage Specification 1 GPRS based concentrator
1.1 Main technical parameters
Working power supply: AC 220V ± 20%, 50Hz (single-phase)
Upstream communication: GPRS wireless mobile network
Downstream communication: low-power wireless mode, 1200BPS
Power consumption: ≤ 10VA
Carrying capacity: capable of managing 255 collectors
Working temperature: -25 ℃ to+65 ℃
Relative humidity: 5% to 85% (non condensing)
1.2 Usage conditions
Installation location requirement: The installation location is covered by China Mobile GSM network signal.
The management center requires that the network servers of the data management center have a fixed IP address. If there is no fixed IP address, a data transmission terminal (GPRS DTU) is required.
1.3 Usage
1) Set server IP and address
The default server IP for the concentrator is 203.171.231.165, port number is 5002, address is 0001, and administrative division code is 0371. Please set the parameters of the concentrator through RS232 serial port based on the fixed IP and port of the data management center, and set the address and administrative code of the concentrator according to actual needs.
2) Concentrator fixed
Fix the concentrator firmly according to the position of the fixing hole of the concentrator. If the concentrator is installed outdoors, it must be installed inside a protective box. Connect the GSM antenna to the antenna terminal on the right side of the concentrator, and connect the RF antenna to the antenna terminal on the left side of the concentrator. Install the GPRS enabled SIM card into the SIM card slot.
3) Connect the power supply
Please connect the concentrator to an AC 220V, 50Hz power supply as shown in the wiring diagram.
4) Set the working parameters of the concentrator
After logging into the management center, the concentrator can set parameters such as date and time, meter reading period, network maintenance period, etc.
5) Download table address
After setting the working parameters of the concentrator, download all the collector addresses and table addresses from the management center software to the concentrator. After downloading, the concentrator can be used normally.
1.4 Explanation of the meaning of indicator lights
IO0: TCP connection indicator light. The concentrator will light up when connected to the server through GPRS network, but it will not light up in other situations.
IO1: PPP connection indicator light. The phone card lights up after registering with the mobile network, but it does not light up in other situations.
IO2: Work indicator light. Flashing in normal operating mode of the system.
IO3: Network status indicator light. It lights up during network hours and not during other times.
IO4: Meter reading period indicator light. It lights up during the meter reading period and does not light up during other periods.
1.5 Precautions
1) The power cord should use RVVB type 2 × 0.75mm2 or thicker wire, and install a leakage protection device. The power supply of the concentrator should be stable and reliable to avoid data transmission failure caused by power interruption.
2) The concentrator can store 31 sets of daily frozen data and 12 sets of daily frozen data for meter reading (the JZQ-GJZR concentrator only stores 12 sets of daily frozen data for meter reading). If the concentrator loses power at the freezing moment, it will not be able to generate frozen data.
3) The concentrator has two matching antennas, with the RF antenna connected to the left side of the bottom shell and the GSM antenna connected to the right side.
4) Only after reliable installation of the antenna and mobile phone card can the concentrator be powered on.
5) If the management center adopts a fixed IP method, it is necessary to ensure that the concentrator IP and port are consistent with the parameters of the management center.
6) The ADD numbers of collectors managed by the same concentrator cannot be duplicated, and a maximum of 255 collectors are allowed, including wireless collectors, meter collectors, and M-bus collectors. When the ADD of the collectors managed by the same concentrator is duplicated, it is necessary to use a handheld device to change the ADD of the collector to a unique ADD.
2. Telephone line concentrator
2.1 Main Technical Parameters
Working power supply: AC 220V ± 20%, 50Hz (single-phase)
Upstream communication: Public Switched Telephone Network
Downstream communication: low-power wireless mode, 1200BPS
Power consumption: ≤ 10VA
Carrying capacity: capable of managing 255 collectors
Working temperature: -25 ℃ to+65 ℃
Relative humidity: 5% to 85% (non condensing)
2.2 Usage conditions
1) The installation location of the concentrator has a telephone line (supporting extension lines).
2) The meter reading server in the management center has an RS232 communication serial port.
3) The meter reading equipment for the concentrator is an external modem MODEM.
2.3 Instructions for use
1) Set address
The default address inside the concentrator is 0001 and the administrative division code is 0371. According to actual needs, set the address and administrative code of the concentrator through the RS232 serial port.
2) Concentrator fixed
According to the position of the concentrator fixing hole, fix the concentrator. If the concentrator is installed outdoors, it must be installed inside a protective box. Connect the RF antenna to the antenna terminal on the left side of the concentrator, and follow the wiring diagram to connect the telephone line to the corresponding terminal.
3) Connect the power supply
Please connect the concentrator to an AC 220V, 50Hz power supply as shown in the wiring diagram.
4) Set the working parameters of the concentrator
After establishing a dial-up connection through a modem and concentrator, the management center can set parameters such as date and time, meter reading period, network maintenance period, etc.
5) Download table address
After setting the working parameters of the concentrator, download all the collector addresses and table addresses from the management center software to the concentrator. After downloading, the concentrator can be used normally.
2.4 Explanation of the meaning of indicator lights
IO0: Telephone line communication indicator light. It lights up during data communication and does not light up at other times.
IO1: Debug the serial communication indicator light. It lights up during data communication and does not light up at other times.
IO2: Work indicator light. Flashing in normal operating mode.
IO3: Network status indicator light. It lights up during network hours and not during other times.
IO4: Meter reading period indicator light. It lights up during the meter reading period and does not light up during other periods.
2.5 Precautions
1) The power cord should use RVVB type 2 × 0.75mm2 or thicker wire, and install a leakage protection device. The power supply of the concentrator should be stable and reliable to avoid data transmission failure caused by power interruption.
2) The concentrator can store 31 daily frozen data and 12 meter reading daily frozen data. If the concentrator loses power at the freezing moment, it will not be able to generate frozen data.
3) The connection of the concentrator antenna should be reliable and not loose.
4) The ADD numbers of collectors managed by the same concentrator cannot be duplicated, and a maximum of 255 collectors are allowed, including wireless collectors, electric meter collectors, and M-bus collectors. When the ADD of the collectors managed by the same concentrator is duplicated, it is necessary to use a handheld device to change the ADD of the collector to a unique ADD.
3. Ethernet based concentrator
3.1 Main Technical Parameters
Working power supply: AC 220V ± 20%, 50Hz (single-phase)
Upstream communication: Ethernet
Downstream communication: low-power wireless mode, 1200BPS
Power consumption: ≤ 10VA
Carrying capacity: capable of managing 255 collectors
Working temperature: -25 ℃ to+65 ℃
Relative humidity: 5% to 85% (non condensing)
3.2 Usage conditions
Installation location requirement: The concentrator and management center are in the same IP segment, and a fixed internal IP address is assigned to the concentrator.
Management center requirements: The network server of the data management center needs to have a fixed IP address, and the concentrator can form a local area network and allocate necessary ports to the management software.
3.3 Usage Method
1) Set concentrator IP and address
The factory set IP address is 192.168.0.100 and port 8001. Using meter reading software, set the parameters of the concentrator through RS232 serial port based on the IP address, port, concentrator address, and administrative division code assigned to the concentrator by the data management center.
2) Concentrator fixed
According to the position of the concentrator fixing hole, fix the concentrator. If the concentrator is installed outdoors, it must be installed inside a protective box. Connect the RF antenna to the antenna terminal on the left side of the concentrator, and secure the network cable.
3) Connect the power supply
Please connect the concentrator to an AC 220V, 50Hz power supply as shown in the wiring diagram.
4) Set the working parameters of the concentrator
After logging into the management center, the concentrator can set parameters such as date and time, meter reading period, network maintenance period, etc.
5) Download table address
After setting the working parameters of the concentrator, download all the collector addresses and table addresses from the management center software to the concentrator, as well as other necessary parameter settings. Once completed, the concentrator can be used normally.
3.4 Explanation of the meaning of indicator lights:
IO0: Network interface initialization indicator light. Lights up when the network interface initialization is successful, but does not light up in other situations.
IO1: Network physical connection status indicator light. When the network cable is connected normally, it lights up, but it does not light up in other situations.
IO2: Work indicator light. Flashing in normal operating mode of the system.
IO3: Network status indicator light. It lights up during network hours and not during other times.
IO4: Meter reading period indicator light. It lights up during the meter reading period and does not light up during other periods.
3.5 Precautions
1) The power cord should use RVVB type 2 × 0.75mm2 or thicker wire, and install a leakage protection device. The power supply of the concentrator should be stable and reliable to avoid data transmission failure caused by power interruption.
2) The concentrator can store 31 daily frozen data and 12 meter reading daily frozen data (JZQ-EJTH concentrator does not have this function). If the concentrator loses power at the freezing moment, it will not be able to generate frozen data.
3) The concentrator is equipped with an RF antenna, which is connected to the SMA connector on the left side of the top of the concentrator bottom shell.
4) The concentrator can only be powered on after reliable installation of the antenna and network cable.
5) The ADD numbers of collectors managed by the same concentrator cannot be duplicated, and a maximum of 255 collectors are allowed, including wireless collectors, electric meter collectors, and M-bus collectors. When the ADD of the collectors managed by the same concentrator is duplicated, it is necessary to use a handheld device to change the ADD of the collector to a unique ADD.