Shanghai Huaai Chromatography Analysis Technology Co., Ltd
Home>Products>Helium ion detector
Helium ion detector
The GC-9560-PD helium ion chromatograph is suitable for detecting trace impurities in high-purity gases such as hydrogen, oxygen, argon, nitrogen, hel
Product details
  • product description

The national standard GB/T 28726-2012 "Gas Analysis - Helium Ionization Gas Chromatography Method", which was mainly drafted by Hua Ai Chromatography, has been officially announced and implemented since February 1, 2013.

1、 Helium ion detectorTechnical parameters:

1. Detection limit (ppb):

General impurities

Types of groceries

H2

O2Ar

N2

CH4

CO

CO2

inspectmeasurelimit

5

10

10

5

25

5

hydrocarbon

Types of impurities

C2H4

C2H6

C3H6

C3H8

C4H8

C4H10

iC4H10

inspectmeasurelimit

20

20

20

20

20

20

20

2. Temperature control indicators:

  • Column box: 8 ℃ -400 ℃ at room temperature with an accuracy of ± 0.1 ℃
  • Sample injector: Accuracy ± 0.1 ℃ at room temperature between 8 ℃ and 400 ℃
  • Detector: Accuracy ± 0.1 ℃ at room temperature between 8 ℃ and 400 ℃
  • Temperature control quantity: eight channels
  • Program heating: 8th order
  • Heating rate: 1 ℃~40 ℃
  • Cooling rate: within 7 minutes (350 ℃ to 50 ℃)

3Helium ionization detector (PDD)

  • Discharge mode: Pulse discharge
  • Baseline noise: ≤ 0.1mv
  • Baseline drift: ≤ 0.5mv/30min
  • Detection limit: ≤ 1.0 × 10-10g/ml

4. Carrier gas purifier:

  • Purified gases: He, Ar, Ne, Kr, Xe, Rn
  • Maximum operating pressure: 1000Psi
  • Removing gases: H2, O2, N2, CO, CO2, CH4, H2O, NO, NH3, CF4, etc
  • Residual concentration: ≤ 10pppb

5. Workstation performance:

  • Communication interface: RS232/USB interface
  • High precision: 24 bit high-precision A/D
  • Resolution: ± 1UV
  • Input voltage range: -5mv to+1v
  • Sampling frequency: maximum 20 times/second
  • Dynamic range: 106
  • Integral sensitivity: 1 μ v • sec
  • Linearity:<± 0.1%.
  • Reproducibility: 0.06%.

6. Other parameters: size, weight, power supply:

  • Dimensions: Width 655mm x Height 500mm x Depth 480mm
  • Weight:~48kg
  • Power supply: 220V ± 22V, 50Hz, power ≥ 2kW

2、 System configuration:

(1) GC-9560-PDD helium ion chromatograph (2)helium ionization detector(PDHID)
(3) Central cutting system (4) multi column box system
(5) Helium Purifier (6) Standard Gas
(7) Chromatography Column (9) Oxygen Adsorption and Reduction System
(10) Special pressure reducing valve for carrier gas (11), no dead volume dedicated sampling valve

(12) GC-9560V4.0 version reverse control chromatography work

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!