Product Introduction
main featuresComplete Automated Electronic Flow Control (AEFC)
Networked Data Communication and Remote Control System (LAN Communication)
Advanced detector design for industries
Fully localized keyboard and software interface (Chinese version of keyboard and software)
Patented power supply management
Strict environment test for QA (high temperature and high humidity)
Precise programmable oven temperature control
Separated columns oven
High reproducibility of analysis results
Powerful self checking and error reporting function
Can achieve sequence run available
Various valve configurations meet the requirements of Comprehensive Valve Configuration for Complicated Analysis
Micro gas path cutting technology realizes multi position chromatography and backflush functions (Sandwich plate device for two dimension GC and/or back flush, etc.)
technical parameterColumn temperature box
Furnace size: 28 × 30 × 18 cm
Operating temperature range: 5 ℃ to 400 ℃ above room temperature
Temperature setting accuracy: 1 ℃
Maximum order of program temperature rise: 7 orders
Maximum program heating speed: 120℃/min
Longest method runtime: 999.99min
Runable column loss compensation (dual channel)
Injection port
Dual channel injection port
Optional types of injection ports:
Fill column injection port (with spacer purge, can be connected to large-diameter capillary columns)
Capillary Column Split/Non Split Injection Port
Split/non split capillary column injection port
High precision electronic pressure/flow control
Maximum operating temperature 400 ° C
Column head pressure setting range: 0-100psi
Column head pressure control setting accuracy: 0.01psi
Total flow setting range:
0-1000 mL/min (helium)
0-200mL/min (nitrogen)
Flow setting accuracy: 0.1 mL/min
Maximum diversion ratio: 1:1000
Hydrogen flame ionization detector (FID))
High precision electronic flow/pressure control
Compatible with packed columns and capillary columns
Maximum operating temperature 450 ° C
Minimum detection limit:<2.5 picograms of carbon per second
Dynamic linear range: 107 (+10%)
Data collection frequency: up to 100Hz
Thermal conductivity detector (TCD)
High precision electronic flow/pressure control
Suitable for packed columns and capillary columns
The maximum operating temperature is 300 ℃
Data collection frequency: up to 100Hz
Dynamic linear range: 105 (± 10%)
Minimum detection limit:<400 picograms of propane per milliliter (helium)
Electron Capture Detector (ECD)
High precision electronic flow/pressure control
Compatible with packed columns and capillary columns
Maximum operating temperature 400 ° C
Hidden anode (with blowing)
Detector compensation gas type: 5% methane/argon or nitrogen
Data collection frequency: up to 100Hz
Dynamic linear range:> 5X105
Minimum detection limit:< 0.01mCi 63Ni
Nitrogen phosphorus detector (NPD)
High precision electronic flow/pressure control
Compatible with packed columns and capillary columns
Maximum operating temperature 450 ° C
Minimum detection limit:<3 picograms of carbon per second
Dynamic linear range: 105N, 105P
Data collection frequency: up to 100Hz
Minimum detection limit:< 0.2pg N/sec,< 0.2pgP/sec
Selectivity: 25000:1 gN/Gc, 75000:1 gP/Gc