FP0R intelligent unit - AFP0RAD8 analog input unit
The intelligent unit can also be easily compatible with previous models, equipped with compatibility modes for previous models, and can be used withou
Product details
高度仅为90mm,宽度仅为25mm的控制单元。即使扩展至最大3台,宽度也仅为100mm。

No battery, backup all data

The F-type (FP0R-F32) is equipped with the latest device "FRAM", which automatically maintains all data in real-time without the need for backup batteries.
After a long vacation, there is no need to worry about the disappearance of data during the vacation period.
For devices exported or moved overseas, there is no need for battery replacement maintenance.
When replacing equipment, idle devices can be easily restored.
The power supply can be turned off when the equipment is not turned on on weekends to save energy.

Multi axis (4-axis) control can be achieved without the need for expansion units.

Built in 4-axis pulse output, so multi axis motor control can be achieved without the need for an extended positioning unit.

无需扩展单元,也可实现多轴(4轴)控制。

Ultra high speed computational processing

Ultra high speed 80ns/step (ST command)
In the case of 0-3000 steps and 3001 steps or more, the speed can also reach 1.5 times the previous speed
(Note 1) Expansion may result in an extension of the basic time.

No extension: below 0.2ms
Expansion available: below 0.2ms+(1 x number of expansion units) ms

Independent large capacity annotated memory

Easy to maintain and manage the program.

Standard configuration programming port USB

Programming is simple, convenient, and fast! Improved production efficiency.

Abundant positioning function

Realize high-precision positioning control with rich specialized commands.

High-capacity program

Program capacity 32k steps※1Data register 32k words※1

※ 1: In C10/C14/C16, there are 16K steps and a 12 word data register.

positioning

JOG positioning control (command F171)
It can be started without setting a target value. Set the target value by stopping input and execute deceleration stop.

JOG定位控制(命令F171)

■ Set acceleration and deceleration times separately (using commands F171, F172, F174, F175 are valid)
Acceleration time and deceleration time can be set separately.

加减速时间分别设定(使用指令F171,F172,F174,F175有效)

■ Speed change (using commands F171, F172 are valid)
During JOG operation and trapezoidal control, the target speed can be changed through external signals.

速度变更(使用指令F171,F172有效)

Pulse frequency measurement (instruction F178)
Count the number of pulses input for one instruction within a specified time and calculate the frequency.

脉冲频率测定(指令F178)

■ Built in 4-axis pulse output (transistor output type)
It can simultaneously control the interpolation of two sets of 2-axis straight lines.
No complex speed calculations or programs are required, as long as the dedicated instruction (F175) is used to perform 2-axis linear interpolation. Due to the ability to execute 2 sets of controls simultaneously, it is also possible to control both XY workbenches.

内置4轴脉冲输出(晶体管输出型)

High speed counter+pulse output
Combining with the ladder program diagram, the pulse signal emitted by the encoder is measured by a high-speed counter input, and the frequency of the pulse output is adjusted based on this signal to achieve synchronization of the spindle speed from the shaft to the main shaft, and to construct corresponding applications.

高速计数器+脉冲输出
As shown in the above figure, the speed of conveyor belt 1 controlled by the frequency converter is measured by the encoder pulse counting, and the motor (from the shaft) outputs pulses that match the speed (JOG operation), so that the speed of conveyor belt 2 is synchronized.

■ Built in multi-point PWM output (4ch)
The FP0R pulse output port can be used as a PWM output port. The speed of the frequency converter can be controlled by using analog voltage output.

内置多点PWM输出(4ch)

network

■ Connect PLC (MEWNET-W0)
In addition to FP0R, it can be mixed with FP ∑, FP-X, FP2/FP2SH to share contacts and data information among up to 16 PLCs without the need for a program.

连接PLC(MEWNET-W0)

RS485 serial communication
Host/slave compatible with Modbus RTU

Widely used in the Eco market, exerting power in the fields of air conditioning, temperature, and power control

RS485串行通信

Up to 99 units can be connected
When connecting more than 17 FP series products, if Modbus function is used instead of MEWNET-W0, a maximum of 99 can be connected. Each FP0R can be used as both a host and a child, so a multi host link can be established by running the token through the user program.

最多可连接99台

RS232C Universal Serial Communication
Control unit with RS232C port, also corresponding to serial communication.
By using the RS232C port, it can be directly connected to the touch screen and computer. In addition, it can easily achieve bidirectional data transmission with serial devices such as barcode scanners.
The serial port is connected through the S.R.G3 terminal. The touch screen can also be connected through a programming port.
Both relay output and transistor output control units can be equipped with an RS232C serial port.

RS232C通用串行通信

CC Link Slave Unit
Corresponding to the open network CC Link. Maximum 16 point input/16 point output, capable of reading/writing 4-digit data.

CC-Link从站单元

Other convenient functions

■ Program protection
Setting to prohibit uploading programs

Using the tool software FPWIN, you can arbitrarily disable the upload of programs. Close unauthorized copying and protect important programs for customers. The most suitable for operators who use computers to manage raw programs.

程序保护

8-digit password
You can input uppercase and lowercase English letters and numbers, so there are approximately 218 million combinations. After three consecutive input errors, the power supply needs to be powered on again.
Most suitable for operators who need to upload programs through FP0R.


■ Temperature regulation
Using the PID instruction (F356 EZPID), only one line of thermocouple unit instruction needs to be described to implement difficult PLC temperature control programs.
Equipped with two models: 4ch and 8ch, with a comprehensive accuracy of ± 0.8 ℃ (K, J, T range). Up to 3 units can be connected, and high-precision, multi-point PID control of up to 24ch can be achieved.

温度调节

■ Built in RTC real-time clock (T-type only)
Can process data of year, month, day, hour, minute, and second. It can combine regular monitoring of production information, work status, and error message history management with clock data.


■ Interrupt input
Independently of scanning time, it can read input signals at high speed and execute interrupt programs instantly. It can be effectively used for high-precision positioning control and eliminating poor valve control. X0-X7 can be specified in the interrupt input.
(Only C10 is X0-X5)


Pulse capture
Capable of capturing 10 μ s pulse input. It can easily capture sensor signals for detecting smaller components.

脉冲捕捉

Analog unit
The simulation unit has been completely refreshed. There are 5 major models in total: analog input 4ch, 8 ch 2 model, analog output 4ch, analog input/output 2ch/output 1ch, input 4ch/2ch output 2 model. Small body, achieving high resolution of 14 bits and high precision of ± 0.2% (25 ℃).

模拟量单元

EEPROM data storage (instructions F12, P13)
All models of FP0R have built-in EEPROM, which can electrically rewrite data and maintain data without the need for voltage supply. Use instruction P13 to write various set values, production records, etc., and save them. If necessary, it can be read through instruction F12.

EEPROM数据保存(指令F12、P13)

Download program during RUN process (comments can be written)
Even if FP0R is in RUN mode and the device is working, the program edited offline can be fully downloaded to FP0R. Comments can also be written at the same time. No need to stop production due to program replacement.

RUN过程中下载程序(可写入注释)

Intelligent unit

智能单元

It can also be easily compatible with previous models

Equipped with compatibility mode for previous models, it can be used without changing the ladder program diagram.
By using the DIP switch, it can be changed to the compatibility mode of previous models and can work with a resolution of 12 bits.
(Flexible use of program resources)

Previous Model Replacement Table

Types of analog quantities Previous models NEW
input - AFP0RAD4
AFP0401 AFP0RAD8
output voltage AFP04121 AFP0RDA4
current AFP04123
Input/Output AFP0480 AFP0RA21
- AFP0RA42
Product Name Specifications model
FP0R analog quantity
input unit
Number of channels: Input 4ch NEW
AFP0RAD4
Number of channels: Input 48ch NEW
AFP0RAD8
FP0R analog quantity
Input/output unit
Number of channels: Input 42ch/Output 1ch NEW
AFP0RA21
Number of channels: Input 44ch/Output 2ch NEW
AFP0RA42
FP0R analog quantity
output unit
Number of channels: Output 4ch NEW
AFP0RDA4
FP0 thermocouple
unit
K. J, T, R thermocouples with a resolution of 0.1 ℃ AFP0420
K. J, T, R thermocouples with a resolution of 0.1 ℃ AFP0421
Product Name Specifications model Order Product Number
FP0 analog quantity
I/O unit
Input Specifications
Number of channels: 2 channels
Input Range
Voltage 0-5V, -10~+10V (resolution 1/4000)
Current 0-20mA (resolution 1/4000)
FP0-A21 AFP0480
Output Specifications
Number of channels: 1 channel
output range
Voltage -10~+10V (resolution 1/4000)
Current 0-20mA (resolution 1/4000)
FP0 A/D conversion
unit
Input Specifications
Number of channels: 8 channels
Input Range
Voltage 0-5V, -10~+10V, -100~100mV (resolution 1/4000)
Current 0-20mA (resolution 1/4000)
FP0-A80 AFP0401
FP0 D/A conversion
unit
Output Specifications
Number of channels: 4 channels
output range
(Voltage output type) -10~+10V (resolution 1/4000)
(Current output type) 4-20mA (resolution 1/4000)
FP0-A04V AFP04121
FP0-A04I AFP04123

Analog unit specifications

Product Name Analog input unit Analog input/output unit
(Only applicable to the input section)
Order Product Number AFP0RAD4 AFP0RAD8 AFP0RA21 AFP0RA42
Input ch/Output ch 4/0 8/0 2/1 4/2
input range
(Digital input)
Enter the scope)
voltage -10~+10V 14bit(-8,000~+8,000)
-5~+5V 14bit(-8,000~+8,000)
0~+10V 14bit(0~+16,000)
0~+5V 14bit(0~+16,000)
current 0~20mA 14bit(0~+16,000)
Absolute maximum input voltage ±15V
current ±30mA
input impedance voltage About 1M Ω
current About 250 Ω
maximum resolution 14bit( 1/16,000)
Comprehensive accuracy voltage Below ± 0.2% F.S. (+25 ℃)
Below ± 0.4% F.S. (0~+50 ℃)
current Below ± 0.3% F.S. (+25 ℃)
Below ± 0.6% F.S. (0~+50 ℃)
Conversion speed 2ms/full ch
Other functions Average processing (movement, frequency)
Corresponding to the functionality of the old program (12 bits)
Insulation method Input terminal~
internal circuit
between
opto-coupler
Insulation type DC/DC converter
Between channels Non insulated
Product Name Analog output unit Analog input/output unit
(Output only)
Order Product Number AFP0RDA4 AFP0RA21 AFP0RA42
Input ch/Output ch 0/4 2/1 4/2
Output range
(Setting range of analog output)
voltage -10~+10V 14bit(-8,000~+8,000)
-5~+5V 14bit(-8,000~+8,000)
0~+10V 14bit(0~+16,000)
0~+5V 14bit(0~+16,000)
current 0~20mA 14bit(0~+16,000)
4~20mA 14bit(0~+16,000)
output impedance voltage Below 0.5 Ω
Output maximum current voltage ±10mA
Output allowable load resistance current Below 500 Ω
maximum resolution 14bit( 1/16,000)
Comprehensive accuracy voltage Below ± 0.2% F.S. (+25 ℃)
Below ± 0.4% F.S. (0~+50 ℃)
current Below ± 0.3% F.S. (+25 ℃)
Below ± 0.6% F.S. (0~+50 ℃)
Conversion speed 500 μ s/full ch
Other functions Corresponding to the functionality of the old program (12 bits)
Insulation method Input terminal~
internal circuit
between
opto-coupler
Insulation type DC/DC converter
Between channels Non insulated
project Specifications
FP0-A21 FP0-A80
Input points 2 channels/unit 8 channels/unit
Input points converted to possible: 2, 4, 6, 8 channels
Input Range Voltage range 0~5V(K0~K4000 (注1)) / -10~+10V
(K-2000~K+2000 (注1))
0~5V(K0~K4000 (注1)) / -10~+10V
-100~+100mV(K-2000~K+2000 (注1))
current range 0-20mA (K0-K4000 (Note 1))
resolution 1/4000 (12 digits)
Conversion speed 1ms/通道 (注2)
Comprehensive accuracy Below ± 1% F.S. (0-55 ℃), below ± 0.6% F.S. (25 ℃)
input impedance Voltage range Above 1M Ω
current range 250Ω
Maximum absolute ability Voltage range ±15V
current range ±30mA
Insulation method Between the analog input terminal and the internal circuit of FP0:
Optocoupler insulation (no insulation between channels)
Analog input terminal to external power supply room of analog I/O unit:
Insulation type DC/DC converter is used in the power supply room
Between analog input terminal and analog output terminal:
Utilizing insulation type DC/DC converters
Between the analog input terminal and the internal circuit of FP0:
Optocoupler insulation (no insulation between channels)
Analog input terminal to external power supply room of A/D conversion unit:
Utilizing insulation type DC/DC converters
Number of points occupied by input/output contacts 32 input points
Average processing function none Can be switched

(Note 1) When the analog input value exceeds the upper and lower limits, the digital value remains at the upper and lower limits.
(Note 2) To reflect analog data on the input of the control unit, the following time is required.

(Note 3) Set the value of the input channel number conversion switch.
(Note 4) The control unit can obtain data from 2 channels by scanning once. If the input channel number conversion switch is set to 8CH, the data on the control unit can be updated once after scanning 4 times. )

project Specifications
FP0-A21 FP0-A04V FP0-A04I
Output points 1 channel/unit Voltage output 4 channels/unit Current output 4 channels/unit
output range Voltage range -Range of 10~+10V (K-2000~+2000 (Note 1)) -
current range 0-20mA (K0-K4000 (Note 1)) - 4-20mA (K0-K4000 (Note 1))
resolution 1/4000 (12 digits)
Conversion speed 500 μ s/channel (Note 2)
Comprehensive accuracy Below ± 1% F.S. (0-55 ℃), below ± 0.6% F.S. (25 ℃)
output impedance Voltage range Below 0.5 Ω -
Output maximum current Voltage range ±10 mA -
Output load allows for blocking pits current range Below 30 Ω Below 1000 Ω Below 500 Ω
Insulation method (Note 2) Between the analog output terminal and the internal circuit of FP0:
Optocoupler insulation (no insulation between channels)
Analog output terminal to analog I/O unit external:
Insulation type DC/DC converter is used in the power supply room
Use between the analog input terminal and the analog input terminal:
Insulation type DC/DC converter
Between the analog output terminal and the internal circuit of FP0:
Optocoupler insulation (no insulation between channels)
Analog output terminal to D/A conversion unit:
External power supply room
Utilizing insulation type DC/DC converters
Number of points occupied by input/output contacts Output contact 16 points Input contact 16 points, output contact 32 points (Note 3)

When the upper and lower limits of the analog input value are exceeded, D/A conversion is not performed (the analog output still maintains the previous data).
(Note 2) To reflect analog data on the input of the control unit, the following time is required.

(Note 3) The control unit scans once and outputs 2-channel data to the analog output unit.

Thermocouple unit specifications

project Specifications
Input points 4-channel, 8-channel (input/output points converted to possible: 2, 4, 6, 8-channel)
Input Range K. J range -100.0~500.0 ℃/-148.0~790.0(Note 1)
T range -100.0~400.0 ℃/-148.0~752.0
R range 0.0~1500.0 ℃/32.0~1590.0(Note 1)
digital output K. J (at ℃): K -1000~K 5000
K, J(Time: K -1480~K 7900 (Note 1)
(overflow): K -1001,K 5001 Or K 8000)
(When overflow occurs)():K -1481,K 7901 Or K 8000)
(When disconnected: K 8000) (Note 2)
(Data preparation: K 8001) (Note 3)

T (at ℃): K -1000~K 4000
T(Time: K -1480~K 7520
(When overflow occurs (℃): K 1001, K 4001, or K 8000)
(When overflow occurs)(): K -1481, K 7521 or K 8000)
(When disconnected: K 8000) (Note 2)
(Data preparation: K 8001) (Note 3)

R (at ℃): K 0-K 15000
R(Time: K 320-K 15900 (Note 1)
(When overflow occurs (℃): K 0, K 15001 or K 16000)
(When overflow occurs)(): K 0, K 15901 or K 16000)
(When disconnected: K 16000) (Note 2)
(Data preparation: K 16001) (Note 3)
resolution 0.1℃
Sampling period (Note 5) 300ms: When converting input and output points to 2 channels (Note 4)
500ms: When converting input and output points to 4 channels (Note 4)
700ms: When converting input and output points to 6 channels (Note 4)
900ms: When converting input and output points to 8 channels (Note 4)
Comprehensive accuracy K. J range (-100~500 ℃): below ± 0.8 ℃
T range (-100~400 ℃): below ± 0.8 ℃
R range (0-99.9 ℃): below ± 3 ℃ (100-299.9 ℃): below ± 2.5 ℃
(300-1500 ℃): below ± 2 ℃
input impedance Above 1M Ω
Insulation method Thermocouple input terminal to FP0 internal circuit: optocoupler insulation, DC/DC converter insulation
Thermocouple input terminals between channels: PhotoMos relay insulation
The input and output contacts contain a certain number of 32 input points (Note 6)

(Note 1)When expressed in ℉ (Fahrenheit), it will decrease compared to expressed in ℃ (Celsius).
(Note 2) When the thermocouple is disconnected, the numerical value will be displayed as K8000 or K16000 within 70 seconds. To avoid the danger caused by wire breakage, please exchange the thermocouple after handling it.
(Note 3) From power on to completion of data conversion preparation, the numerical value will be displayed as K8001 or K16001. To avoid using data at this time, please develop a corresponding ladder diagram program.
(Note 4) is the set value of the input CH number conversion switch.
(Note 5) After removing the maximum and minimum values from the past 8 conversion values, take the average of the remaining 6 values. Therefore, for sharp temperature changes, the response of numerical values requires a certain amount of time. Scan the control unit once and read 2CH copies of data.
(Note 6) Please use the example program recorded in the product specification book and user manual to read the data.

FP0R/FP0 intelligent unit

Analog unit
[AFP0RAD4 / AFP0RA21]

模拟量单元 [AFP0RAD4 / AFP0RA21]

Analog unit
[AFP0RAD8 / AFP0RDA4 / AFP0RA42]

模拟量单元 [AFP0RAD8 / AFP0RDA4 / AFP0RA42]


Simulated I/O unit


A/D conversion unit

A/D转换单元


D/A conversion unit

D/A转换单元


■ Thermocouple unit

热电偶单元

Optional parts

Wiring tools

Product Name Order Product Number
Terminal block screwdriver
relayOutput type terminal block (Phonenix system) is required for wiring.
AFP0806
Loose wire crimping tool
Transistor output type accessoryconnectorRequired during wiring.
AXY52000

assemble parts

Product Name Order Product Number
FPO installation plate narrow strip 30 type
The mounting plate used for tightening screws. 30mm wide type.
AFP0811
(including 10)
FPO installation plate narrow strip type
The mounting plate used for tightening screws. Narrow strip type.
AFP0803
(including 10)
mounting plate
The mounting plate used for tightening screws. Flat type.
AFP0804
(including 10)

Input/output cable

Product Name Order Product Number
Used for transistor output type
I/O cable

Attached on one sideconnector10 core loose cable AWG22、0.3mm2、 2 pieces (blue/white) 1 piece
Length 1m
2 pieces, 1 set
AFP0521
Length 3m
2 pieces, 1 set
AFP0523

※1 For models such as FP0-C10RS, C14RS, E8RS, E16RS, etc., one set (two books) of I/O cables are required.
※2 For FP0-C16T/E16X and E16T/E16YT models, 1 set (2 pieces) of I/O cables are required each.
※3 For FP0-C32T/E32T/, 2 sets of I/O cables are required (4 in total).

Flat cable connector kit (10 cores)

Flat cable connector kit core AFP0808 (4-pack)

Repair parts

Product Name Order Product Number
Terminal socket
Accessory relayOutput/terminal block type.
Repair components.
AFP0802
(Including 2)
Loose wire crimping socket
Belonging to the transistor output type
AFP0807
(Including 2)
FP0R power cable
(1m in length)
Attached to FP0R control unit.
Afpg 805
(1 pack)

Loose wire crimping connector

Product Name Order Product Number Applicable cable size wire gauge
Cable diameter remark
Loose wire crimping connector AXW7221FP AWG#22 φ1.5~φ1.1 AWG # 22 12/0.18
AWG#24 twisted pair
AXW7231FP AWG#26 φ1.3~φ1.1 twisted pair
AWG#28 twisted pair

4-point unit relay (power PhotoMOS type)

<
Contact composition category Rated input voltage 4-point unit relay
model Order Product Number Quantity per package
1a×4 DC dedicated
(Equipped with AQZ102)
DC12V RT3SP1-12V