Tag: Three dimensional flux gate sensor, three-axis flux gate probe, three component flux gate Mag-13 data processing unit, weak magnetic measurement, geomagnetic measurement
Provide professional magnetic field measurement solutions | ||||||
Strong magnetic field measuring instrument(0 - 20T) | ||||||
model |
principle |
type |
number of axles |
DCaccuracy |
maximum range |
Highest resolution |
X113 |
hall |
hall sensor |
1 |
<> |
15T |
TC: 30ppm/K |
G80 |
hall |
handheld |
1 |
2% |
2T |
10μT |
G81 |
hall |
handheld |
1 |
0.8% |
10T |
1μT |
G82 |
hall |
handheld-high frequency |
1 |
0.8% |
10T |
1μT |
G83 |
hall |
handheld |
3 |
0.8% |
10T |
1μT |
G92 |
hall |
handheld |
1 |
1% |
10T |
10μT |
G93 |
hall |
handheld |
3 |
1%, 0.5% |
20T |
1μT |
G201 |
hall |
Desktop computer |
1 |
0.2% |
10T |
1μT |
G203 |
hall/reluctance |
Desktop computer |
3 |
0.2% |
10T |
10nT |
G401 |
hall |
Desktop computer |
1 |
0.04% |
10T |
1μT |
G403 |
hall |
Desktop computer |
3 |
0.04% |
10T |
1μT |
GSP301A |
hall |
Analog transmitter |
1 |
1%, 0.2% |
10T |
Output: ±3V |
GSP301D |
hall |
Digital transmitter |
1 |
1%, 0.2% |
10T |
1μT |
GSP303D |
hall |
Digital transmitter |
3 |
1%, 0.2% |
20T |
1μT |
GSP303D-S |
hall |
Digital transmitter |
3 |
0.5%, 0.1% |
3T |
1μT |
Magnetic field testing system | ||||||
GAS3000 |
Array magnetic field detection system, synchronous detection up to128The magnetic field at a certain location |
|||||
GMS980 |
High precision Gaussian meter calibration system (High precision Tesla meter calibration device) |
|||||
Weak magnetic field measuring instrument(0- 2mT) | ||||||
Weak magnetic field Gaussian meter | ||||||
model |
principle |
type |
number of axles |
DCaccuracy |
maximum range |
Highest resolution |
GMR61 |
reluctance |
handheld |
1 |
0.8% |
600μT |
10nT |
GMR63 |
reluctance |
handheld |
3 |
0.8% |
600μT |
10nT |
GF601 |
fluxgate |
handheld |
1 |
0.5% |
1mT |
0.1nT |
GF603 |
fluxgate |
handheld |
3 |
0.25% |
1mT |
0.1nT |
GF633 |
fluxgate |
Desktop computer |
3 |
0.1% |
100μT |
0.01nT |
GFP703 |
fluxgate |
Smart Transmitters |
3 |
0.5% |
1mT |
0.1nT |
GFP703S |
fluxgate |
Spectrum analyzer |
3 |
0.5% |
1mT |
0.01nT |
GFP803 |
fluxgate |
Smart Transmitters |
3 |
0.2% |
1mT |
0.1nT |
Communication magnetic field measurement(DC- 1MHz) | ||||||
model |
principle |
type |
number of axles |
ACaccuracy |
maximum range |
frequency response |
AMS-2K |
alternating current coil |
Analog sensor |
1 |
1% |
3mT |
30Hz- 2kHz |
AMS-1M |
alternating current coil |
Analog sensor |
1 |
1% |
3mT |
2kHz- 1MHz |
G1000 |
reluctance |
Smart Transmitters |
3 |
DC- 1% AC- 2% |
400μT/ Axis |
DC- 1MHz |
GA1000 |
reluctance |
handheld |
3 |
2% |
400μT/ Axis |
30Hz- 1MHz |
GSP301HFA |
reluctance |
Analog transmitter |
1 |
1% |
150μT |
20Hz-1.2MHz |
GSP303HFA |
reluctance |
Analog transmitter |
1 |
1% |
150μT |
20Hz-1.2MHz |
fluxgate sensor | ||||||
model |
principle |
type |
number of axles |
noise level |
maximum range |
output |
F901 |
fluxgate |
Economic type |
3 |
10 to 20pT |
1000μT |
±10V,single-ended |
F902 |
fluxgate |
low noise |
3 |
<> |
100μT |
±10V,single-ended |
F903 |
fluxgate |
low-power consumption |
3 |
10 to 20pT |
200μT |
±3V,finite difference |
F904 |
fluxgate |
low-power consumption|low noise |
3 |
<> |
100μT |
±3V,finite difference |
F905 |
fluxgate |
high-performance|low noise |
3 |
<> |
100μT |
±10V,single-ended |
F906 |
fluxgate |
low-power consumption |
3 |
10 to 20pT |
100μT |
±3V,finite difference |
F23 |
fluxgate |
split type|large range |
3 |
<> |
1500μT |
±10V,single-ended |
F53 |
fluxgate |
High temperature type |
3 |
≤ 300pT@175℃ |
100μT |
±5V,finite difference |
Magnetic flux gate sensor data acquisition unit | ||||||
FDU301 |
Connectable1A three-axis flux gate sensor |
|||||
ASA1000 |
Connectable2-126A single axis flux gate sensor or2-42A three-axis flux gate sensor |
|||||
AFS |
Array flux gate sensor detection system, capable of connecting multiple flux gate magnetic field transmitters |
|||||
GMR-16 |
Micro weak magnetic field sensor array, capable of synchronous acquisition2-16Data from a miniature weak magnetic field sensor |
|||||
GR100 |
Digital three-axis flux gate gradiometer |
|||||
remarks: 1Magnetic field unit conversion:1T= 10kG; 1mT= 10G; 1μT= 10mG; 1nT= 10μG 2Click on the left side of the table abovemodelYou can refer to the product information of the corresponding model |
FDU301 three channel high-precision magnetic sensor data acquisition board
sketch:
The FDU301 flux gate sensor data acquisition unit is a portable 3-channel, 24 bit data acquisition unit that is compatible with a 3D flux gate sensor, such as Barton brand Mag-03, Mag-13, and Mag690, or COLIY brand F901, F902, and F905.
The FDU301 flux gate sensor data acquisition unit uses three 24 Bits 1600ksps ADCs, with a dynamic range of up to 145dB, to convert magnetic field strength into digital signals at high speed and precision. The digital output (RS485) rate can be set between 1sps-1ksps.
characteristic | |
● Digitize a three-dimensional flux gate sensor ● compatibleBartingtonThree dimensional flux gate sensor ● compatibleCOLIYThree dimensional flux gate sensor ● DCCoupling, providing spectrum analysis functionality ● Power supply:±15V(Typical value) |
● Circuit accuracy up to0.01% ● Sample Rate1600ksps (24 bits ADC) ● High magnetic field resolution0.1nT(1μG) ● Output digital signal(RS485) ● Provide upper computer software and calibration software |
Upper computer software interface
Calibration software interface
【 Usage conditions: Equipped with a weak magnetic field generation system 】
Technical parameters:
model |
FDU301 |
performance parameter | |
Number of input channels |
3 (X, Y, Z) [Connectable1A three-dimensional flux gate sensor] |
Input signal range |
±10V (Single ended mode) |
Sensor requirements |
Three dimensional flux gate sensors, such asBartingtonBrand'sMag-03、Mag-13、Mag690andCOLIYBrand'sF901、F902、F905class |
accuracy |
0.01% |
frequency response |
DC- 10kHz |
Sample Rate |
≤1600ksps (24 bit ADC) |
Digital signal output |
RS485interface |
output rate |
Digital output rate1sps- 1kspsoptional |
Magnetic field resolution |
up to0.1nT(10μG) [When the range is±100μT, output rate≤50sps] up to1nT(0.1mG) [When the range is±1000μT, output rate≤50sps] |
The longest cable length for digital output |
500m |
Electrical specifications | |
Provide power supply to sensors |
±15VDC,<±5%>±5%>Or as specified by the customer |
power supply |
±15VDC,accuracy<>Ripple and noise≤50mVp-p |
power consumption |
<> |
PCBworkmanship |
war industryAlevelFR-4Board, standard thickness, green, gold-plated/Tin plating process |
Component selection |
All onboard components are industrial grade |
Component welding |
useSMTSurface mounting method (reflow soldering or wave soldering) |
protection grade |
Three proof treatment for circuit board |
Environmental requirements | |
operation temperature |
-20℃to +80℃ |
storage temperature |
-20℃to +85℃ |
Related humidity |
0 to90%non-condensing |
Environmental magnetic field |
≤20G(2mT) |
Upper computer software | |
Data display digits |
up to7position |
function |
1Automatically record and display trend chart curves; 2Real time display of component and vector values of magnetic field strength; 3Real time storage of magnetic field strength data to a computer; 4Can perform spectrum measurement and display(option). |
Optional Accessories
type |
describe |
Software-spectrum |
SMART PC Software(Upper computer software)Spectrum analysis function |
PS2015 |
Power adapter: Input100VAC- 240VAC Output voltage:±15VDC,±5% Rated output current:0.8A RIPPLE AND NOISE≤50mVp-p |
S485USB |
RS485changeUSBadapter |
MCS100 |
Weak magnetic field generation system, customized according to user requirements |
※※※Click to view other magnetic measurement devices ※※※ |