Shenzhen Kerei Technology Development Co., Ltd
Home>Products>F23 3D Flux Gate Sensor
F23 3D Flux Gate Sensor
F23 3D Flux Gate Sensor
Product details


Provide professional magnetic field measurement solutions

Strong magnetic field measuring instrument(0 - 20T)

model

principle

type

number of axles

DCaccuracy

maximum range

Highest resolution

X113

hall

hall sensor

1

<>

15T

TC: 30ppm/K

G80

hall

handheld

1

2%

2T

10μT

G81

hall

handheld

1

0.8%

10T

1μT

G82

hall

handheld-high frequency

1

0.8%

10T

1μT

G83

hall

handheld

3

0.8%

10T

1μT

G92

hall

handheld

1

1%

10T

10μT

G93

hall

handheld

3

1%, 0.5%

20T

1μT

G201

hall

Desktop computer

1

0.2%

10T

1μT

G203

hall/reluctance

Desktop computer

3

0.2%

10T

10nT

G401

hall

Desktop computer

1

0.04%

10T

1μT

G403

hall

Desktop computer

3

0.04%

10T

1μT

GSP301A

hall

Analog transmitter

1

1%, 0.2%

10T

Output: ±3V

GSP301D

hall

Digital transmitter

1

1%, 0.2%

10T

1μT

GSP303D

hall

Digital transmitter

3

1%, 0.2%

20T

1μT

GSP303D-S

hall

Digital transmitter

3

0.5%, 0.1%

3T

1μT

Magnetic field testing system

GAS3000

Array magnetic field detection system, synchronous detection up to128The magnetic field at a certain location

GMS980

High precision Gaussian meter calibration system (High precision Tesla meter calibration device)

Weak magnetic field measuring instrument(0- 2mT)

Weak magnetic field Gaussian meter

model

principle

type

number of axles

DCaccuracy

maximum range

Highest resolution

GMR61

reluctance

handheld

1

0.8%

600μT

10nT

GMR63

reluctance

handheld

3

0.8%

600μT

10nT

GF601

fluxgate

handheld

1

0.5%

1mT

0.1nT

GF603

fluxgate

handheld

3

0.25%

1mT

0.1nT

GF633

fluxgate

Desktop computer

3

0.1%

100μT

0.01nT

GFP703

fluxgate

Smart Transmitters

3

0.5%

1mT

0.1nT

GFP703S

fluxgate

Spectrum analyzer

3

0.5%

1mT

0.01nT

GFP803

fluxgate

Smart Transmitters

3

0.2%

1mT

0.1nT

Communication magnetic field measurement(DC- 1MHz)

model

principle

type

number of axles

ACaccuracy

maximum range

frequency response

AMS-2K

alternating current coil

Analog sensor

1

1%

3mT

30Hz- 2kHz

AMS-1M

alternating current coil

Analog sensor

1

1%

3mT

2kHz- 1MHz

G1000

reluctance

Smart Transmitters

3

DC- 1% AC- 2%

400μT/ Axis

DC- 1MHz

GA1000

reluctance

handheld

3

2%

400μT/ Axis

30Hz- 1MHz

GSP301HFA

reluctance

Analog transmitter

1

1%

150μT

20Hz-1.2MHz

GSP303HFA

reluctance

Analog transmitter

1

1%

150μT

20Hz-1.2MHz

fluxgate sensor

model

principle

type

number of axles

noise level

maximum range

output

F901

fluxgate

Economic type

3

10 to 20pT

1000μT

±10V,single-ended

F902

fluxgate

low noise

3

<>

100μT

±10V,single-ended

F903

fluxgate

low-power consumption

3

10 to 20pT

200μT

±3V,finite difference

F904

fluxgate

low-power consumption|low noise

3

<>

100μT

±3V,finite difference

F905

fluxgate

high-performance|low noise

3

<>

100μT

±10V,single-ended

F906

fluxgate

low-power consumption

3

10 to 20pT

100μT

±3V,finite difference

F23

fluxgate

split type|large range

3

<>

1500μT

±10V,single-ended

F53

fluxgate

High temperature type

3

≤ 300pT@175

100μT

±5V,finite difference

Magnetic flux gate sensor data acquisition unit

FDU301

Connectable1A three-axis flux gate sensor

ASA1000

Connectable2-126A single axis flux gate sensor or2-42A three-axis flux gate sensor

AFS

Array flux gate sensor detection system, capable of connecting multiple flux gate magnetic field transmitters

GMR-16

Micro weak magnetic field sensor array, capable of synchronous acquisition2-16Data from a miniature weak magnetic field sensor

GR100

Digital three-axis flux gate gradiometer

remarks:

1Magnetic field unit conversion:1T= 10kG; 1mT= 10G; 1μT= 10mG; 1nT= 10μG

2Click on the left side of the table abovemodelYou can refer to the product information of the corresponding model



F23Three dimensional flux gate sensor


sketch:

F23The 3D flux gate sensor is a magnetic field sensor with independent intellectual property rights that can be mass-produced by Koley Company after years of effort. Koley Company has the ability to design new shapes and analog output characteristics based on user needs, and can integrate acceleration sensors, temperature sensors, etc. into flux gate sensors.F23The typical application scenarios of 3D flux gate sensors include geomagnetic detection, package detection, underwater magnetic field monitoring, traffic monitoring, residual magnetism measurement, weak magnetic field measurement, laboratory, etc.

F23Three dimensional flux gate sensor with selectable range±70μT±100μT±500μT±1000μTand±1500μTFrequency responseDC-3kHzThe linearity is less than0.01%The three-axis orthogonality error is less thanAnd noise<20pt rms/√hz='' at=''>20pt>. Use24positionADCAfter digitization,DCResolution can reach up to0.1nT.

F23The 3D flux gate sensor has two packaging specifications:F23andF23SAmong themF23It is an integrated design that encapsulates the 3D flux gate probe and circuit module together;F23SIt is a split type, small probe (size)24x24x40mm)Independently packaged, through1.5Meter cable, connecting circuit modules, suitable for measuring in narrow spaces. Product according toMTBF(Mean time between failures)10Annual design.



characteristic

l Three dimensional flux gate sensor

l Linearity:<>

l Three axis orthogonality error:<>

l Power supply:±12VDC ~ ±16VDC

l analog signaloutput±10V

l range±70μT ~ ±1500μTAny optional

l Accuracy:<>

l Noise level:<20pt rms/√hz='' ='' at=''>20pt>

l Frequency response range:DC- 3kHz

l Two packaging specifications: integrated and split



F23Three dimensional flux gate sensor parameters:


model

F23 / F23S

performance parameter

number of axles

3 (XYZRight-Handed Coordinate System)

range

X, Y, Z

±70μT

±100μT

±500μT

±1000μT

±1500μT

vectorR

121μT

173μT

866μT

1732μT

2598μT

accuracy

<>

noise level

<20pt rms/√hz='' ='' at='' 1hz =''>20pt>range≤±100μT)

Start Time

150ms

Warm-up time

15mins

Analog Output

±10V (single-ended output)

sensitivity

143mV/μT

100mV/μT

20mV/μT

10mV/μT

6.6mV/μT

Absolute zero point

< ±100nt =''>range≤±100μT)

Typical zero drift

±0.5nT/(range≤ ±100μT)

Typical temperature coefficient

±100ppm/(range≤ ±100μT)

Three-axis orthogonality error

< 1°=''>

Linearity

<>least-squares fit)

frequency response(-3dB)

> 3kHz

hysteresis

<2nt>2nt>Exposed to magnetic field environments up to twice the range)

MTBF

10year(Mean time between failures)

Mechanical dimensions

IntegratedF23

24 x 24 x 125mm

split typeF23S

Probe:24x24x40mmCircuit module:30 x 25 x 107mm; Connection cable length:1.5m

Electrical specifications

supply voltage

±12VDCto±16VDC

Typical power consumption

240mW

Environmental requirements

operation temperature

- 40to +60

storage temperature

- 40to +70

protection grade

IP67




Terminal Description


Cable color

connecting terminal

describe

brown

X

Analog signal single ended output(XAxis,±10V)

yellow

Y

Analog signal single ended output(YAxis,±10V)

green

Z

Analog signal single ended output(ZAxis,±10V)

blue

AGND

signal ground

black

PGND

Power Ground

red

P13

DC IN

(±12VDCto±16VDC)

white

N13

Note: Sensitivity is equal to±10VDivided by the range of the flux gate sensor, please refer to the parameter table for details.



Selection of Three Dimensional Flux Gate Sensors


F23

-100

-1m

Three dimensional flux gate sensor types

F23Integrated 3D Flux Gate Sensor

F23SSplit type 3D flux gate sensor

Sensor range

-7070μT/axle

-100100μT/axle

-500500μT/axle

-10001000μT/axle

-15001500μT/axle

Cable Length

-1m1rice

-2m2rice

-5m5rice

......

Note:

1Model example:F23-100-5mThis is an integrated 3D flux gate sensor(F23)The range is100μT/axle(100),Cable Length5rice(5m)

2The longest cable length100m100Mi Nei can be customized;

3Maximum sensor range1500μT1500μTThe interior can be customized.


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!