Electric pole tension detectionIndicator functional conditions
1. Purpose: Measurement1Test within 00KN
Measurement: Winding type 18Displacement measurement within 00mm
(Display unit 1mm)
Force display unit
1At 00KN The reading is 0.1KN
1At 0KN The reading is 0.01KN
3. Displacement display unit in millimeters
4. Measurement accuracy ≤1% . Reading ± 1 word
5. Force display adjustmentzerozero adjustment
6. Zero adjustment of displacement display
7. Environmental temperature for use -5℃ ~+45℃
8. Use environmental humidity 80% (relative humidity)
9. Power supply voltage range~220 ± 15% (50Hz)
10. There is no strong magnetic field around during use.
11. Allowable load error: 1%
Electric pole tension detectionUsage:
1. First, connect the selected load sensor to the "Force Signal Input" socket on the left side of the rear panel of the tester using a five core cable signal line10KN or1After zeroing, it displays 000KN
2. TakeTwist the displacement sensor and displacement signal line. The other end is connected to the socket on the back panel (displacement input) of the tester.
3. Connect the power socket to the rear panel of the tester(220V power supply)Plug in socket, withConnect the 220V power supply.
4. Press the front panel (power switch) to turn on the light, and the LCD will display numbers.
5.At this time, turn the zero knob of the two windows and adjust them to000
The 6.00mm displacement sensor should display 000mm
7.Load window display readingThe 10KN sensor is 00.000KN
An instrument suitable for measuring the load characteristics and displacement changes of cement electric poles.
Electric pole tension testing is an instrument suitable for measuring the load characteristics and displacement changes of cement electric poles. The product meets the testing requirements for load, deflection, and displacement of cement rods in GB/T4623-2014 "Mechanical Test Methods for Circular Cement Products"; It also meets the one paper certification review requirements of State Grid and Southern Power Grid.