Electric pole load deflection tester with bracketSpecially designed for testing conical rods, detailed parameters are as follows:
1. Purpose: Measurement within 200KN for testing
Measurement: Displacement measurement within 1800mm using wire winding method
(Minimum display unit 1mm)
Direct sliding 50mm displacement sensor
(Minimum display unit 0.1mm)
Direct sliding 20mm displacement sensor
(Minimum display unit 0.01mm)
2. Force display unit
At 200KN The reading is 0.1KN
At 20KN The reading is 0.01KN
3. Displacement display unit in millimeters
4. Measurement accuracy ≤1% . Reading ± 1 word
5. Adjust the force display to zero
6. Zero adjustment of displacement display
7. Environmental temperature for use -5℃ ~+45℃
8. Use environmental humidity 80% (relative humidity)
9. Power supply voltage range~220 ± 15% (50Hz)
10. There is no strong magnetic field around during use.
Electric pole load deflection tester with bracketConfiguration List:
Display one host;
A 20KN tension sensor with a built-in lifting ring;
A 200KN tension sensor with a built-in lifting ring;
A 1800mmC point deflection sensor with a base;
A 50mmA point displacement sensor with a base;
A 50mmB point displacement sensor with a base;
Power cord, shielded wire, instruction manual, certificate of conformity;
Battery box;
Sensor mobile bracket (used to fix deflection sensors)
toolbox