principle |
By detecting the frequency of piezoelectric crystal elements, the mass concentration value of floating dust is tested |
test subject |
Mass concentration of indoor and outdoor suspended particulate matter |
Test particle size |
Below 10 μ m (Building Management Law) Below 2.5 μ m |
test scope |
0~10mg/m3 |
test accuracy |
± 10% of the reading |
Test time |
120 seconds, 24 seconds, 10-3600 seconds (set through menu) |
maximum load |
2000Hz or 10 μ g |
Particle sorting mechanism |
Inertial impact type particle separation mechanism (impactor) |
Communication interface and speed |
RS-2324800bps, 9600bps, 19200bps (set through menu) |
data storage |
500 pieces |
attract traffic |
1L/min |
clean |
Manual cleaning of crystals |
power supply |
AC/DC adapter (AC100-240V) with built-in Ni MH battery (9.6V-1.5AH), continuous use time of about 4.5 hours, charging time of 5-8 hours |
Random attachment |
1 cleaning box, 2 sponges for the box, 100cc cleaning agent, 1 strap, 1 sponge pressure plate, 1 AC/DC adapter, 1 Φ 7.07 μ impactor nozzle, 1 communication cable, 1 communication software CD, and 1 user manual |
Select items |
Printer, printer adapter |