The Labonce-300CFS series two box drug stability testing chamber adopts a structural design and uses high-quality imported components, suitable for long-term continuous operation, with stable and reliable performance, and suitable for cGMP certified users.
1. The adopted air duct system design ensures good temperature and humidity uniformity at different positions inside the box, with two independent control systems for each box;
2. European original imported fully enclosed industrial compressor, high efficiency, low noise, ensuring long-term continuous operation of the equipment;
3. European original imported temperature and humidity integrated sensor, high sensitivity, low annual drift, directly detects humidity without maintenance;
4. Imported temperature and humidity controller, fast sensing, small system error, imported paper recorder, high-precision curve recording throughout the process;
5. The inner liner is made of fully mirrored stainless steel 304, which is pollution-free and easy to clean;
6. Equipped with an alarm system that meets cGMP requirements and a data acquisition system that meets cGMP requirements;
7. Meets ICH2003 Q1A (R2), CP2010, and follows the following standards: GB/T 10586-2006. |
Name |
Drug stability test box(Two boxes of comprehensive, cGMP) |
Model number |
Labonce-300CFS |
Box number |
A |
B |
Temperature control range |
10~65℃ |
10~65℃ |
Temperature control fluctuation |
±0.5℃ |
Temperature deviation |
±1.5℃ |
Moisture control range |
40~95%RH |
Humidity fluctuation |
±3%RH |
Humidity deviation |
±4%RH |
Range of illumination |
0~8000LUX |
N/A |
Illuminance deviation |
±500LUX |
N/A |
Temperature and humidity control method |
BTHC |
Refrigeration system |
Imported fully enclosed compressors (two sets) |
Humidity sensor |
Imported capacitive humidity sensors (two sets) |
Controller |
Imported temperature and humidity controllers (two sets) |
Data recording |
Imported paper recorders (two sets) |
Test point |
40 ℃ 75% RH 25℃ 60%RH |
Temperature deviation alarm |
Temperature upper and lower limit deviation alarm |
Humidity deviation alarm |
Humidity upper and lower limit deviation alarm |
Double protection |
Independent over temperature protection system |
Working environment temperature |
+5~35℃ |
Inner liner material |
Mirror stainless steel 304 |
Shell material |
Steel plate spray coating |
Water tank |
External water tank |
Power supply |
AC 220V±10% 50HZ |
Safety device |
Compressor overheating, fan overheating, over temperature, compressor overpressure, overload, water shortage protection |
Zui High Power (kW) |
1.5 |
1.5 |
Volume (L) |
150 |
150 |
Internal dimensions (mm) W × D × H |
680×500×460 |
680×500×460 |
Dimensions (mm) W × D × H |
840×870×1850 |
Shelf (standard) |
2 |
2 |
Note 1 |
The A box of this equipment comes standard with a 320-400nm near ultraviolet light source; Labonce-300FS is a specially designed reserved model without lighting system |
|