1、 Product Overview
As the name suggests, high and low voltage distribution cabinets are distribution equipment used in power supply systems for energy distribution, control, metering, and cable connection. Generally, power supply bureaus and substations use high voltage switchgear,
Then, the low-voltage side of the transformer is stepped down and led out to the low-voltage distribution cabinet. The low-voltage distribution cabinet is connected to various power distribution panels, control boxes, and switch boxes. Inside, some switches, circuit breakers, fuses
A power distribution device that integrates protective devices such as buttons, indicator lights, instruments, and wires to meet the design functional requirements. Commonly known as high and low voltage switchgear or complete sets of high and low voltage electrical equipment.
2、 Model and meaning
3、 Normal usage conditions
At+35% C.
2. For indoor installation and use, the altitude of the usage location shall not exceed 2000m.
3. The relative humidity of the surrounding air should not exceed 50% at a maximum temperature of+40C, and should be maintained at a lower temperature
3. ZhouThe relative humidity of the surrounding air should not exceed 50% at a maximum temperature of+40C, and should be maintained at a lower temperature
Allow for a relatively high relative temperature(For example, 90% at+20 ° C) Considering the temperature variation
The effect of condensation may occur accidentally.
4. The inclination of the equipment during installation with respect to the vertical plane shall not exceed 5 degrees.
5. The equipment should be installed in a place without severe vibration and impact, and not enough to subject electrical components to
Go to a place of corrosion.
6. When users have special requirements, they can negotiate with the manufacturer to resolve them.
4、 Main technical parameters
| model | Rated voltage (V) | Rated current (A) | Rated short-circuit breaking current (kA) | Rated short-time withstand current (1s) (kA) | Rated peak withstand current (kA) |
| GGD1 |
380 |
A 100 |
15 |
15 | 30 |
| B 600(630) | 15 | 30 | |||
| C 400 | 15 | 30 | |||
|
GGD2 |
380 |
A 1500(1600) |
30 |
30 | 63 |
| B 1000 | 30 | 63 | |||
| C 600 | 30 | 63 | |||
|
GGD3 |
380 |
A 3150 |
50 |
50 | 105 |
| B 2500 | 50 | 105 | |||
| C 2000 | 50 | 105 |
5、 Structural features
| Product code | A | B | C | D |
| GGD06 | 600 | 600 | 450 | 556 |
| GGD06A | 600 | 800 | 450 | 756 |
| GGD08 | 800 | 600 | 650 | 556 |
| GGD08A | 800 | 800 | 650 | 756 |
| GGD10A | 1000 | 600 | 850 | 556 |
| GGD10A | 1000 | 800 | 850 | 756 |
| GGD12 | 1200 | 800 | 1050 | 756 |
6、 Appearance and dimensions (mm)




7、 Ordering Notice
The parameters in this plan are the standard configuration provided by our company. If the customer has no specific requirements, the company will supply according to the standard configuration. If it exceeds the requirements of this plan, please explain separately.