1、 Product Overview

As the name suggests, high and low voltage distribution cabinets are distribution equipment used in power supply systems for energy distribution, control, metering, and cable connection. Generally, power supply bureaus and substations use high voltage switchgear,
Then, the low-voltage side of the transformer is stepped down and led out to the low-voltage distribution cabinet. The low-voltage distribution cabinet is connected to various power distribution panels, control boxes, and switch boxes. Inside, some switches, circuit breakers, fuses
A power distribution device that integrates protective devices such as buttons, indicator lights, instruments, and wires to meet the design functional requirements. Commonly known as high and low voltage switchgear or complete sets of high and low voltage electrical equipment.


2、 Model and meaning


3、 Normal usage conditions

1. The ambient air temperature should not be higher than+400 and not lower than -5C, and the average temperature within 24 hours should not be high
At+35% C.
2. For indoor installation and use, the altitude of the usage location shall not exceed 2000m.
3. The relative humidity of the surrounding air should not exceed 50% at a maximum temperature of+40C, and should be maintained at a lower temperature
3. ZhouThe relative humidity of the surrounding air should not exceed 50% at a maximum temperature of+40C, and should be maintained at a lower temperature
Allow for a relatively high relative temperature(For example, 90% at+20 ° C) Considering the temperature variation
The effect of condensation may occur accidentally.
4. The inclination of the equipment during installation with respect to the vertical plane shall not exceed 5 degrees.
5. The equipment should be installed in a place without severe vibration and impact, and not enough to subject electrical components to
Go to a place of corrosion.
6. When users have special requirements, they can negotiate with the manufacturer to resolve them.


4、 Main technical parameters

model Rated voltage (V) Rated current (A) Rated short-circuit breaking current (kA) Rated short-time withstand current (1s) (kA) Rated peak withstand current (kA)
GGD1 380
A 100 15
15 30
B 600(630) 15 30
C 400 15 30
GGD2
380
A 1500(1600) 30
30 63
B 1000 30 63
C 600 30 63
GGD3
380
A 3150 50
50 105
B 2500 50 105
C 2000 50 105


5、 Structural features

Product code A B C D
GGD06 600 600 450 556
GGD06A 600 800 450 756
GGD08 800 600 650 556
GGD08A 800 800 650 756
GGD10A 1000 600 850 556
GGD10A 1000 800 850 756
GGD12 1200 800 1050 756


6、 Appearance and dimensions (mm)








7、 Ordering Notice

The parameters in this plan are the standard configuration provided by our company. If the customer has no specific requirements, the company will supply according to the standard configuration. If it exceeds the requirements of this plan, please explain separately.