Main applications
The product is mainly used in cities, parks, colleges, and parksRailway tunnelsCentralized control and energy consumption monitoring of road lighting, streetlights, and landscape lighting in highways, stations, docks, tourist attractions, and other places.

Product appearance diagram
Technical parameter table(Model: PT-JZ-2005-TL)
|
Serial Number |
project |
Test conditions |
parameter |
|||
|
Min |
Typ |
Max |
Uints |
|||
|
1 |
rated operational voltage |
/ |
185 |
220 |
255 |
VAC |
|
2 |
power consumption |
/ |
2 |
— |
3 |
W |
|
3 |
relay |
Once per second |
Self-hold |
/ |
||
|
4 |
Relay contact capacity |
AC220V/10A |
— |
10 |
— |
A |
|
5 |
Rated load power |
/ |
— |
400 |
600 |
W |
|
6 |
Overload action current |
/ |
— |
4 |
— |
A |
|
7 |
communication model |
/ |
Zigbee |
/ |
||
|
8 |
Working frequency band |
/ |
2400~2483.5MHz |
MHz |
||
|
9 |
operation temperature |
/ |
-40 |
25 |
85 |
℃ |
|
10 |
Working humidity |
/ |
5 |
— |
95 |
% |
|
11 |
VOLTAGE MONITOR |
three-phase four-wire system |
||||
|
12 |
current monitoring |
Output line current |
||||
|
13 |
Switch light control |
Multiple ways of turning on and off lights, including time control, light control, manual control, scene control, etc |
||||
|
14 |
Signal monitoring |
Level, pulse, lightning surge protection |
||||
|
15 |
Single lamp monitoring communication |
Power line carrier or ZigBee wireless communication methods, multiple scene control modes |
||||
|
16 |
temperature monitoring |
Accuracy 0.0625 ℃ |
||||
|
17 |
Access control monitoring |
Proximity type door magnetic switch |
||||
|
18 |
Meter reading interface |
National standard DLT/645 electric meter reading protocol (partial) |
||||
|
19 |
environmental monitoring |
PM2.5 laser collection method |
||||
|
20 |
Server communication method |
Data transmission: 2G/3G/4G/wifi/network port and other communication methods |
||||
|
21 |
Dimming output |
PWM pulse width modulator signal, DC0-10V |
||||
|
22 |
Optical control interface |
Measurement range: 0-20000 Lux |
||||
|
23 |
Backup power supply |
Six hour delayed work protection |
||||
|
24 |
data shows |
Display and adjustment of system time, device ID, light on/off time, etc |
||||
|
25 |
status indicator |
Alarm for power outage, tripping, open circuit, short circuit, etc |
||||
|
26 |
Switch light control mode |
Multi time scenario pre value |
||||
|
27 |
Switch light button |
Fully open, fully close button |
||||
|
28 |
Equipment volume |
500mm*160mm*600mm(L×B×H) |
||||
|
29 |
degrees of protection provided by enclosure |
IP65 |
||||
Function Description
A centralized controller device based on ZigBee communication method, the communication network adopts Mesh self-organizing network method, the working frequency band is 2.4-2.5GHz, the transmission rate is 250kbps, and the maximum transmission power can reach 19dBm, which complies with IEEE802.15.4 standard. Through the concentrator (including ZigBee function), it can interact with remote servers, making it convenient for management personnel to coordinate and supervise.Communication with the server can be achieved through 4G, Ethernet, fiber optic, and other communication methods.Management personnel can control all single lights remotely through the server switch or the fully open and fully closed buttons in centralized control.
after-sale service
Product warranty for 1 year, 24-hour service hotline