Product Introduction Usage Technical Support Biosafer-40AS Ultra Pure Water Machine Process Features: Based on the design concept of "layer by layer p
Product details
  • Biosafer-40AS Ultra Pure Water Machine

    Process characteristics:

    According to the design concept of "layer by layer protection, step by step filtration", pre-treatment is configured based on the source water conditions, which is more targeted; Flexible selection of single-stage or two-stage reverse osmosis processes is more reasonable and economical to use; Dow Low Voltage in the United StatesROMembrane, desalination rate ≥98%The system combines automatic cleaning and manual flushing to ensure long-term and efficient operation; Heraeus GermanyHerauesDual wavelength ultraviolet lamp and the United StatesAquaBestA digestion instrument that can efficiently sterilize and degrade organic matter; Rohm and HaasRohm HaasNuclear grade deep processing polishing mixed bed purification and ultra pure unit water quality resistivity and reach18.25ΜΩ·cm@25℃; According to usage requirements, imported ultrafiltration membranes and degassing membranes are selected to thoroughly filter out heat sources, soluble gases, and ultra pure water quality. High precision terminal microporous filters are also selected.


    Functional features:

    An integrated system for producing pure and ultrapure water using tap water as the water source.

    Four user password protection function. Real time monitoring of RO and UP water quality operation status.

    Complete management functions such as RO pure water and ultra pure water production, system water intake, system circulation, and disinfection.

    The ultra pure water system has built-in circulation settings to prepare the best required UP water quality. The ultrapure water circulation system can be freely started and turned off to maintain a low bacterial contamination state.

    Adopting imported RO membrane from Dow DOW in the United States. Fully automatic RO membrane anti scaling flushing program, manual/automatic flushing time can be set to extend the service life of RO membrane.

    Complete water free protection, high-pressure water full protection functions, and fault alarm functions.

    Complete historical alarms, historical water intake records, and consumable life management functions, displaying consumable usage time and automatically reminding replacement upon expiration.

    Water quality detection sensor resistance cell constant: 0.01-1, temperature sensitivity ± 0.1 ℃, with automatic temperature compensation function at 25 ℃

    Equipped with analog pressure sensors and analog liquid level sensors, it can directly display the inlet pressure and water tank storage capacity.

    Ultra large capacity integrated two column ultra purification column module. The whole body column is made of food grade PP material, without any adhesive or impurities. The interior is equipped with imported American Rohm and Haas electronic grade UP6150 and semiconductor grade UP6040 nuclear grade polishing resins, with a maximum effluent quality of 18.25M Ω· cm.

    Using Heraeus 185/254nm dual wavelength ultraviolet sterilization from Germany. The energy contained in the 254nm spectral line can effectively destroy the DNA molecular structure of microorganisms such as bacteria and viruses, achieving the purpose of sterilization; The 185nm spectral line can also decompose organic molecules in water and ultimately oxidize them to carbon dioxide, effectively removing TOC.

    Using low voltage 24VDC as the main power supply, with a layout of water and electricity separation, in compliance with safety regulations, high-strength engineering plastic chassis, to prevent corrosion and rust.

    Ultra low radiation. Adopting advanced electromagnetic compatibility design, it has strong anti-interference ability and low noise.


    Working conditions:

    Water source: Urban municipal tap water(TDS≥300Enhanced pre-processing units are added to the system;

    Temperature:545℃

    Source water pressure:15Kg/cm2

    Power Supply:220V 50Hz

    power3080W

    Technical Parameter

    Water production capacity(25℃40L/h
    Pure water quality: conductivity≤0.5μS/ cm@25 ℃The water quality standard is better than that of Chinese national laboratory water(GB6682-2008)Grade III water standard
    Ultra pure water quality:conductivity≤0.055μS/ cm@25 ℃; electrical resistivity18.25ΜΩ· cm@25 ℃The water quality standard is better than that of Chinese national laboratory water(GB6682-2008)First level water standard
    Water intake flow rateROPure water:2L/minUPUltra pure water:1.8L/min
    Heat source:/
    TOC<10ppb
    Microorganisms:<1cfu/ml
    Micro particles: (greater than)0.2μm)Content: <1/ml
    screen size4.3cun

    Exterior dimensions long×wide×tall455×535×515mm


    remarks:

    This product has obtained CE certification.


    Related products:

    model Biosafer-5AS Biosafer-10AS Biosafer-20AS Biosafer-30AS Biosafer-40AS
    water source Municipal tap water Municipal tap water
    Municipal tap water
    Municipal tap water
    Municipal tap water
    water yield 5L/h
    10L/h
    20L/h
    30L/h
    40L/h
    Pure water quality
    Conductivity ≤ 0.5 μ S/ cm@25 ℃
    Conductivity ≤ 0.5 μ S/ cm@25 ℃
    Conductivity ≤ 0.5 μ S/ cm@25 ℃
    Conductivity ≤ 0.5 μ S/ cm@25 ℃
    Conductivity ≤ 0.5 μ S/ cm@25 ℃
    Ultra pure water quality
    Electrical resistivity 18.25 Μ Ω· cm@25 ℃
    Electrical resistivity 18.25 Μ Ω· cm@25 ℃
    Electrical resistivity 18.25 Μ Ω· cm@25 ℃
    Electrical resistivity 18.25 Μ Ω· cm@25 ℃
    Electrical resistivity 18.25 Μ Ω· cm@25 ℃
    RO water/ultrapure water intake flow rate 2/1.8 L/min 2/1.8 L/min
    2/1.8 L/min
    2/1.8 L/min
    2/1.8 L/min
    heat source / /
    /
    /
    /
    TOC <10ppb
    <10ppb
    <10ppb
    <10ppb
    <10ppb
    microorganism
    ﹤1cfu/ml
    ﹤1cfu/ml
    ﹤1cfu/ml
    ﹤1cfu/ml
    ﹤1cfu/ml
    Micro particles (larger than 0.2 μ m) ﹤1/ml
    ﹤1/ml
    ﹤1/ml
    ﹤1/ml
    ﹤1/ml

  • Application standard level experiments, preparation of high-purity standard solutions, quantitative analysis, blood testing, toxicity testing, preparation of buffer solutions, atomic absorption/emission spectroscopy, liquid chromatography, gas chromatography, etc.
  • Selection method of laboratory pure water machine

    Working principle of laboratory pure water machine

    Analysis of Common Laboratory Malfunctions

    Purification methods for water
  • Online inquiry
    • Contacts
    • Company
    • Telephone
    • Email
    • WeChat
    • Verification Code
    • Message Content

    Successful operation!

    Successful operation!

    Successful operation!