Differential pressure alarm, when we hear its name, we will think what kind of machine it is. so-calledDifferential pressure alarmIt is the most common type of wind pressure sensor in industry, with a wide range of applications. It can be said that having it in industry will save a lot of time and effort. Especially on dust collectors, spraying equipment, air conditioning filters, boiler furnace negative pressure and positive pressure air supply systems. Next, Century Travel Gan Gong will take you to learn more about itDifferential pressure alarm.
This device consists of two parts:
1) Digital display screen
2) Wind pressure differential sensor
This product adopts a wind pressure measurement core imported from the United States, with a dual row 4-digit digital display that displays the measured differential pressure value and the control output differential pressure value (which can be freely set by the user); Equipped with power indicator light (power switch button) and sound and light alarm.


Introduction to the automatic detection alarm of bag filter differential pressure sensor:
measurement range |
Differential pressure/wind pressure: 0-5KPA |
|||
Allow overvoltage |
2 times the full-scale pressure |
|||
measuring medium |
Non corrosive, dust-free, dry gas |
|||
Comprehensive accuracy: linear, repetitive, and hysteresis |
±0.1%FS |
±0.2%FS |
±0.4%FS |
|
medium temperature |
-20℃~85℃ |
|||
compensation temperature |
-10℃~70℃ |
|||
ambient temperature |
-10℃~70℃ |
|||
Zero temperature drift |
Typical: 0.02% FS/℃ |
:0.05%FS/℃ |
||
Sensitivity temperature drift |
Typical: 0.02% FS/℃ |
:0.05%FS/℃ |
||
long-term stability |
Typical: ± 0.1% FS/year |
± 0.2% FS/year |
||
power supply range |
12~36VDC (usually 24VDC) |
|||
signal output |
4~20mA / 1~5V DC / 0~5V DC / 0.5~4.5V DC |
|||
load resistor |
≤(U-12)/0.02 Ω |
|||
housing material |
PP quantity or 304 stainless steel |
|||
Protection level |
IP65 or IP67 |
|||
process connection |
Φ 8 nozzle with M10x1 installation screw (special can be threaded connection) |
|||
Explosion-proof marking |
Exia II CT5 (Intrinsically Safe Explosion proof Type) |
|||
weight |
About 0.35Kg |
|||
Vibration error |
≤±0.01%FS(X、Y、Z 轴, 200Hz/g) |
|||
response time |
≤2 ms |
|||
insulation resistance |
100MΩ,500V DC |
|||
Easy to use. Suitable for measuring pressure or differential pressure of various dry and non corrosive gases, with high measurement accuracy. After precise temperature calibration, amplification and external processing, it is converted into a 4-20mA standard signal and interfaces with industrial computers or distributed systems. It is very simple, with M4 screw mounting holes on both sides of the body and threads on the air nozzle. Users can choose to fix it with screws or M10 * 1.5 nuts. The default pressure interface is a φ 8 Baota nozzle, where the long nozzle is a high-end pressure interface and the short nozzle is a low-end pressure interface. (Alternatively, a diameter of 6 pagoda spout or quick connector can be used)
Specially added display function to achieve on-site display and synchronous display of the machine position, making it convenient for on-site personnel to watch and debug. Advanced circuit linearity and temperature compensation technology; Make the transmitter perform better. Compact and sturdy structure; Small size and light weight; Easy installation; Easy to use. Suitable for measuring pressure or differential pressure of various dry and non corrosive gases, with high measurement accuracy. Through precise temperature calibration, amplification and external processing, it is converted into a 4-20mA standard signal and interfaces with industrial computers or distributed systems. It is widely used for measuring air duct pressure or flow in petroleum, chemical, metallurgy, and power plants, achieving automatic measurement and control of production processes.


Bag filter differential pressure sensor automatic detection alarmProduct Usage
One purpose is to detect whether the filter (dust collector) is clogged. There are impurities in the gas, and the purpose of using a filter is to filter these impurities. When the filter filters out too many impurities, the pressure difference between the front and rear of the filter will increase (will it be clogged), so a pressure difference transmitter is needed to monitor the working condition of the filter. If the pressure difference increases, the filter needs to be replaced or cleaned.
Another use is that when the filter is blocked, the gas cannot pass through, and the pressure at the back of the filter will decrease. Air may enter the gas pipeline from the gas outlet and mix with the gas, which may cause an explosion when you ignite it again. Therefore, for safety reasons, this differential pressure transmitter should be installed. Based on the above two reasons, this differential pressure transmitter must be installed.


Bag filter differential pressure sensor automatic detection alarm usage instructions:
The pressure difference alarm adopts imported high-performance pressure sensing chips, combined with advanced circuit processing and temperature compensation technology, which can accurately measure the magnitude of gas pressure difference. It has the advantages of high sensitivity, high accuracy, strong overload resistance, strong anti-interference ability, and long-term stability and reliability.
1. Wiring instructions:
There is an 8P wiring terminal block inside the differential pressure alarm, as shown in the figure on the right. 1 and 2 are connected to 220V AC power, and 6, 7, and 8 are the normally closed, normally open, and common terminals of the relay, respectively.
2. Panel Description:
As shown in the figure, PV displays the measured value, SV displays the alarm value, and when the measured value is greater than the alarm value, the pressure difference alarm will sound. The differential pressure alarm has two alarm outputs AL1 and AL2. When AL1 alarms, the AL1 indicator light will light up, the alarm indicator light will flash and emit a buzzing sound. When AL2 alarms, the AL2 indicator light will light up, and the relay will act. The relay interface is the three terminals on the right side (6, 7, 8) of the 8P terminal block.
The pressure difference alarm displays the alarm value of SV1 by default when powered on, and the factory default values of SV1 and SV2 are 1500, which means that when the pressure difference is greater than 1500PA, the alarm will sound. Press the settings button to switch between displaying two alarm values SV1 and SV2, and press the increase and decrease buttons to set the alarm values.
3. Installation method:
1. Install self tapping screws, open the cover, insert self tapping screws into the installation holes at the four corners, fix them on the wall and installation plate, and then cover the cover back.
2. Hanging feet installation: The alarm is equipped with 4 mounting feet, which can be installed at the bottom of the housing and then fixed to the wall or mounting plate with screws.
4. Installation precautions:
1. Interface size: A diameter of 8 tower head, with the long port being a high-voltage interface and the short port being a low-voltage interface. If connected in reverse, the PV value will be negative.
When measuring clean gas, it can be installed freely. When measuring humid or dirty gas, the pressure port must be installed perpendicular to the ground to prevent foreign objects from entering the pressure port.
Product application:
This system can be used in environmental protection and dust removal alarm protection systems for industries such as sheet metal processing, furniture manufacturing, casting industry, ceramic industry, glass industry, refractory materials, cement building materials, grinding wheel manufacturing, chemical products, and mechanical processing. It provides basic data support for the stable operation of the dust removal system, alarms and processes abnormal information that occurs during the operation of the dust removal system, improves the operating efficiency of the dust removal equipment, ensures the safe and stable operation of the dust removal system, and achieves the goal of environmental protection and dust removal.
The differential pressure alarm has two pressure ends, divided into a high pressure end (H) and a low pressure end (L). Measure the pressure difference between the high and low voltage ends. So how to determine the differential pressure range? Firstly, the system pressure during normal operation of the tested system should be considered, which can also be referred to as unilateral pressure. Secondly, it is necessary to determine the value of the pressure difference between the tested end and the reference end, that is, the range of the pressure difference alarm. If the high-pressure end pressure of the tested device must be higher than the low-pressure end, a single range can be selected, such as 0-10Kpa, 0-10Kpa; If you cannot determine the high voltage end, you can choose+-1KPa or+-10Kpa, so that both ends can be connected freely and testing is more convenient.
Example 1: Check if the performance of the filter meets the standards. When the inlet pressure of the filter is 300KPa and the outlet pressure of the filter is less than 280KPa, the filter needs to be replaced. So, when selecting a differential pressure transmitter, you can choose based on the parameters of a system pressure of 300KPa and a differential pressure range of 20Kpa.
Example 2: Check the consistency of pressure inside two high-pressure tanks. The standard pressure inside the tank is 1 megapascal, and both tanks are inflated simultaneously to ensure that the pressure difference between the two tanks is less than 1 kilopascal. Then we can select the range of the differential pressure transmitter based on the parameters of system pressure of 1 megapascal and differential pressure+-1 kilopascal.