1、 Product Introduction:

1. Temperature range: 0 ℃ to 100 ℃

2 APT.line ™ Preheating chamber technology

3. Cooling through a compression cooler

4. Adjustable fan speed

5. Controller using interval programming and real-time programming

6. Working hour timer

7. Interior door made of safety glass (ESG)

8. Two sockets made of stainless steel

9. Stackable

10. Independently adjustable temperature safety device Class 3.1 (DIN 12880), equipped with optical and acoustic temperature alarms

11. Computer interface: RS 422

2、 Technical parameters:

PRODUCT MODEL KB023-230V1 KB023UL-120V1
Choose a model standard standard
Item code 9020-0112 9020-0113
measure
Internal volume [L] 20 20
Net weight of equipment (unloaded) [kg] 44 44
Maximum total load [kg] 25 25
Maximum load per partition [kg] 10 10
The dimensions of the casing do not include additional components and connectors
Net weight width [mm] 435 435
Net weight at height [mm] 620 620
Depth net weight [mm] 520 520
Wall distance from rear [mm] 100 100
Wall to side distance [mm] 100 100
Internal dimensions
Width [mm] 222 222
Height [mm] 330 330
Depth [mm] 277 277
The number of doors
Inner door 1 1
Outer door 1 1
Data related to the environment
Energy consumption at 40 ℃ [Wh/h] 60 60
Sound pressure level [dB (A)] 47 47
firmware
Number of partitions (hours/maximum) 2/3 2/3
Temperature performance data
Temperature range [℃] 0…100 0…100
The temperature deviation is 37 ℃ [± K] 0.3 0.3
Temperature fluctuation at 37 ℃ [± K] 0.1 0.1
Heating time to 37 ℃ [min] 11 11
The recovery time after opening the door in 30 seconds is 37 ℃ [min] 2 2
Electric data
Rated voltage [V] 230 120
Power frequency [Hz] 50/60 60
Rated power [kW] 0.3 0.3
Equipment safety device [A] 10 12.5
Phase (rated voltage) 1~ 1~

1. All technical data is only applicable to standard specifications of unloaded equipment at an ambient temperature of 22 ± 3 ℃ and a power supply voltage fluctuation of ± 10%. Determine temperature data according to BINDER factory standards and DIN 12880:2007, and adapt to the recommended wall gap of 10% of the internal chamber height, width, and depth. For series devices, all data are typical averages. The technical data assumes a fan speed of 100%. We reserve the right to make technical changes.