ASA1000 high-precision analog synchronous acquisition system
Description: • Can access any analog signal • Can synchronously collect data from 2-126 single axis analog sensors or 2-42 three-axis analog sensors •
Product details


Provide professional magnetic field measurement solutions

Strong magnetic field measuring instrument(0 - 20T)

model

principle

type

number of axles

DCaccuracy

maximum range

Highest resolution

X113

hall

hall sensor

1

<>

15T

TC: 30ppm/K

G80

hall

handheld

1

2%

2T

10μT

G81

hall

handheld

1

0.8%

10T

1μT

G82

hall

handheld-high frequency

1

0.8%

10T

1μT

G83

hall

handheld

3

0.8%

10T

1μT

G92

hall

handheld

1

1%

10T

10μT

G93

hall

handheld

3

1%, 0.5%

20T

1μT

G201

hall

Desktop computer

1

0.2%

10T

1μT

G203

hall/reluctance

Desktop computer

3

0.2%

10T

10nT

G401

hall

Desktop computer

1

0.04%

10T

1μT

G403

hall

Desktop computer

3

0.04%

10T

1μT

GSP301A

hall

Analog transmitter

1

1%, 0.2%

10T

Output: ±3V

GSP301D

hall

Digital transmitter

1

1%, 0.2%

10T

1μT

GSP303D

hall

Digital transmitter

3

1%, 0.2%

20T

1μT

GSP303D-S

hall

Digital transmitter

3

0.5%, 0.1%

3T

1μT

Magnetic field testing system

GAS3000

Array magnetic field detection system, synchronous detection up to128The magnetic field at a certain location

GMS980

High precision Gaussian meter calibration system (High precision Tesla meter calibration device)

Weak magnetic field measuring instrument(0- 2mT)

Weak magnetic field Gaussian meter

model

principle

type

number of axles

DCaccuracy

maximum range

Highest resolution

GMR61

reluctance

handheld

1

0.8%

600μT

10nT

GMR63

reluctance

handheld

3

0.8%

600μT

10nT

GF601

fluxgate

handheld

1

0.5%

1mT

0.1nT

GF603

fluxgate

handheld

3

0.25%

1mT

0.1nT

GF633

fluxgate

Desktop computer

3

0.1%

100μT

0.01nT

GFP703

fluxgate

Smart Transmitters

3

0.5%

1mT

0.1nT

GFP703S

fluxgate

Spectrum analyzer

3

0.5%

1mT

0.01nT

GFP803

fluxgate

Smart Transmitters

3

0.2%

1mT

0.1nT

Communication magnetic field measurement(DC- 1MHz)

model

principle

type

number of axles

ACaccuracy

maximum range

frequency response

AMS-2K

alternating current coil

Analog sensor

1

1%

3mT

30Hz- 2kHz

AMS-1M

alternating current coil

Analog sensor

1

1%

3mT

2kHz- 1MHz

G1000

reluctance

Smart Transmitters

3

DC- 1% AC- 2%

400μT/ Axis

DC- 1MHz

GA1000

reluctance

handheld

3

2%

400μT/ Axis

30Hz- 1MHz

GSP301HFA

reluctance

Analog transmitter

1

1%

150μT

20Hz-1.2MHz

GSP303HFA

reluctance

Analog transmitter

1

1%

150μT

20Hz-1.2MHz

fluxgate sensor

model

principle

type

number of axles

noise level

maximum range

output

F901

fluxgate

Economic type

3

10 to 20pT

1000μT

±10V,single-ended

F902

fluxgate

low noise

3

<>

100μT

±10V,single-ended

F903

fluxgate

low-power consumption

3

10 to 20pT

200μT

±3V,finite difference

F904

fluxgate

low-power consumption|low noise

3

<>

100μT

±3V,finite difference

F905

fluxgate

high-performance|low noise

3

<>

100μT

±10V,single-ended

F23

fluxgate

split type|large range

3

<>

1500μT

±10V,single-ended

F53

fluxgate

High temperature type

3

≤ 300pT@175

100μT

±5V,finite difference

Magnetic flux gate sensor data acquisition unit

FDU301

Connectable1A three-axis flux gate sensor

ASA1000

Connectable2-126A single axis flux gate sensor or2-42A three-axis flux gate sensor

AFS

Array flux gate sensor detection system, capable of connecting multiple flux gate magnetic field transmitters

GMR-16

Micro weak magnetic field sensor array, capable of synchronous acquisition2-16Data from a miniature weak magnetic field sensor

GR100

Digital three-axis flux gate gradiometer

remarks:

1Magnetic field unit conversion:1T= 10kG; 1mT= 10G; 1μT= 10mG; 1nT= 10μG

2Click on the left side of the table abovemodelYou can refer to the product information of the corresponding model




High precision analog synchronous acquisition system ASA1000


sketch:

COLIY's high-precision analog synchronous acquisition system ASA1000 has accumulated years of experience in high-precision analog conversion design and has unique advantages.

The high-precision analog synchronous acquisition system ASA1000 has 3 analog inputs and is equipped with a built-in ± 13.5VDC and 5VDC power supply for external sensor power supply. It can synchronously collect data from 2-126 single axis sensors (such as Bartington brand Mag670, COLIY brand F710 flux gate sensor), or from 2-42 three-axis sensors (such as Bartington brand Mag690, Mag-03, Mag-13 three-axis flux gate sensor and COLIY brand F901, F902, F905 three-axis flux gate sensor, etc.). The collection speed of each channel can be set between 1sps-40ksps. The power consumption of each A/D acquisition circuit is very low, only 50mW/channel.

The high-precision analog synchronous acquisition system ASA1000 uses USB 2.0 digital communication with the computer, and the collected data is directly imported into the computer through USB 2.0. The high-precision analog synchronous acquisition system ASA1000 can be customized according to user needs, and can synchronously collect up to 250 analog inputs to meet customers' higher requirements.

The high-precision analog synchronous acquisition system ASA1000 has the advantages of high accuracy, high stability, high resolution, miniaturization, digitization, and intelligence. With the continuous development of science and technology and the emergence of new materials and processes, the application scope of this system will continue to expand.





Performance advantages:
1. It can access any analog signal, including: unipolar single ended signal, unipolar differential signal, bipolar single ended signal, bipolar differential signal, and pseudo differential signal.

2. The following 8 analog input ranges can be manually selected, or automatic ranges can be selected:

Bipolar differential signal

Bipolar single ended signal

Monopolar single ended or differential signal

±10 V

0-±10 V

0-10 V

±5 V

0-±5 V

0-5 V

±2.5 V

0-±2.5 V

0-2.5 V

±1.25 V

0-±1.25 V

0-1.25 V

±0.625 V

0-±0.625 V

0-0.625 V

±0.312 V

0-±0.312 V

0-0.312 V

±0.156 V

0-±0.156 V

0-0.156 V

±0.0781

V

0-±0.0781 V


0-0.0781 V3. Typical pairing probe (sensor)

model

brand

number of axles

type of output

maximum range

frequency response

Linearity

internal noise

Mag670

1

BartingtonSingle ended ±

10V1000±μ

T

DC- 1kHz

0.01%

10- 20pT

Mag690

3

BartingtonSingle ended ±

10V1000±μ

T

DC- 1.5kHz

0.01%

10- 20pT

Mag-03

3

BartingtonSingle ended ±

10V1000±μ

T

DC- 3kHz

0.0015%

“S”: 6-10pTL”:

<>

Mag-13

3

BartingtonSingle ended ±

10V1000±μ

T

DC- 3kHz

0.0015%

“S”: 6-10pTL”:

<>

“Q”: <>

F701

1

COLIYSingle ended ±

10V100±μ

T

DC- 1kHz

0.01%

6-10pT

F901

3

COLIYSingle ended ±

10V1000±μ

T

DC- 1kHz

0.01%

10- 20pT

F902

3

COLIYSingle ended ±

10V200±μ

T

DC- 1.6kHz

0.005%

6-10pT

F905

3

COLIYSingle ended ±

10V100±μ

T

DC- 3kHz

0.0015%

“S”: 6-10pTL”:



<>

4. The analog input terminal can withstand an absolute input voltage range of ± 15V

5. Impedance of analog input terminal: 1G Ω

6. Zero offset voltage:<>

7. Zero offset voltage temperature drift:<10nv c=''>10nv>

8. Gain temperature drift: 1ppm/° C

9. Gain linearity:<>

10. ADC conversion bits: 24 bits

11. Synchronous sampling rate: 1sps-40ksps adjustable




12. Extremely low noise:<0.5 µ vrms (resolution 0.025ppm)=''>0.5 µ vrms>







Upper computer software:


Performance parameters of the synchronous array magnetic field detection system ASA1000:Synchronous array magnetic field detection system

ASA1000

power supply

100VAC - 240VAC

Number of connectable analog quantities2-126Optional(250It can also be customized according to user requirements, up toindividual

)

Analog signal form

Can access any form of analog signal

8Analog range settingMultiple range options available

(0.0781 V - 10V)

Maximum absolute voltage of analog input±

15VADC

Convert digits

24 bits

gain linearity

<>

Gain temperature drift1ppm/°

C

Zero point voltage<>μ

V

Zero point voltage temperature drift<10nv>10nv>°

C

noise
<0.5µvrms>0.5µvrms>
<0.2µvrms>0.2µvrms>

<0.02µvrms>0.02µvrms>

Analog input impedance1G

Ω

Synchronous sampling rate1sps-40ksps

adjustable

Sampling trigger

Internal digital triggering and external voltage pulse triggering

Power consumption of analog sampling circuit50mW/

road

built-in power supplyProvide ±13.5VDCand5VDC

Power supply to the sensor

operating systemWindows XPperhaps

Win10

Computer configuration requirements

Conventional mainstream configuration

1Supporting software functionsSet the data collection speed, and the system will synchronize the collection speed quickly3ksps/

Road;2

Automatically synchronize the collection of test data at each point and summarize and display it;3

Data saving, drawing various curve charts, etc

operation temperature-25ºCto

+60ºC

storage temperature-40ºCto



+80ºC


Selection of ASA1000 synchronous array magnetic field detection system:

describe

option

give an example

Synchronous array magnetic field detection system

ASA1000

ASA1000

2

4

8

......

126

48



Number of collection channels
Note:

1. Model ASA1000-48, indicating the ability to connect 48 analog inputs simultaneously;






Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!