3510 Atomic Absorption Spectrophotometer Standard Type
The AA3510 flame atomic absorption spectrometer product introduction has been modified based on the 6810 atomic absorption spectrophotometer. It is an
Product details

AA3510Product Introduction of Flame Atomic Absorption Spectrometer



in6810On the basis of atomic absorption spectrophotometer, modifications have been made. It is an economical flame type atomic absorption spectrophotometer launched by our company. It has excellent performance, easy operation, accurate indicators, and stable performance, which can meet many common needs and is deeply loved by users.

Main Features

in6810On the basis of original absorption, considering commonly used user functions, selective trade-offs have been made for some performance, resulting in extremely high cost-effectiveness

Good instrument stability, wide measurement range, low detection limit, high resolution, high sensitivity

The original optical path design greatly improves the sensitivity in the ultraviolet region, with outstanding mechanical and optical systems, as well as excellent software to ensure measurement accuracy

fastChange the gas flow rate,Fast rotating grating, slit, element lamp

Widely used for element quantitative analysis in scientific fields such as rare earth analysis, precious metal analysis, environmental protection, water quality testing, alloy materials, building materials, medicine and health, and higher education institutions

Practical structure, easy to operate, and easy to master

Fully meet the needs of users who only perform flame analysis

Can be equipped with laughing gas function to expand the measurement range and meet the needs of customers in different fields

technical indicators
Wavelength range:190~900nm

Grating line density:1800article/mm

wavelengthheavyRestoration:±0.1nm

Wavelength indicationError:Full band±0.2nm
Optical system:Czerny-TurnerSystem, integrated optical platform, Fully enclosed optical system

Resolution:Spectral bandwidth0.2nmCan separate manganese double lines(279.5and279.8)And the valley peak energy ratio is less than30%

Spectral slit:4Automatic gear switching)0.1nm0.2nm0.4nm1.0

nmStatic baseline drift:

0.002ABS/30min(Cu)Background correction technology:D2Background deduction method(background signal1ABS50When deducting background ability ≥times

)Body design:

Suspended integrated structure of internal and external optical paths4Lamp holder:4Lamp lighthouse(

The lights above can be preheated simultaneouslyCombustion head:air-Acetylene flame combustion head(100mmOptional laughing gas function50mm

Nebulizer:

Efficient glass atomizerDynamic baseline drift of ignition:

0.004ABS/30min(Cu)Characteristic concentration of copper:

0.025μg/ml/1%Detection limit:Cu

0.006ug/mlMeasurement repeatability for copper: 0.5%(Cu,Absorbance>

0.8ABS)Gas flow control:

manualIgnition method:

Instrument operation panel buttonssafeguard:

Automatically cut off gas in case of insufficient pressure, power interruption, abnormal flameout, or mismatched combustion headBackground deduction method:Self absorption and deuterium lamp two ways of attaching background, can be calibrated1ABackground. background signal1A50When deducting background ability ≥

Twice.Size:700mm×550mm×